Swan-Ganz VIP

Swan-Ganz VIP and VIP+ thermodilution catheters are pulmonary artery catheters for assessing a critically ill patient’s hemodynamic condition. They support direct intracardiac and pulmonary…

Registry build 21.09.26

Swan-Ganz VIP and VIP+ thermodilution catheters are pulmonary artery catheters for assessing a critically ill patient’s hemodynamic condition. They support direct intracardiac and pulmonary artery pressure monitoring, cardiac output determination, and infusion of solutions.

An inflatable balloon at the catheter tip helps blood flow carry it into the pulmonary artery. The catheter connects to a compatible Edwards monitoring system for the measurements supported by its model.

Listed Item

Swan-Ganz VIP+ TRI-Lumen Infusion Thermodilution Catheter

Blood Sampling and Supply

The distal pulmonary artery port permits mixed venous blood sampling for assessment of oxygen transport balance and related calculations. The catheter is supplied sterile after ethylene oxide sterilization and is intended for single use.

1manufacturer
3catalogue numbers in this listing
5510(k) clearances naming this product code
21recalls on this code

Who Else Makes It

Registered in Shandong. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code DYG
Manufacturer City Province Registered as Device types
Bioxin Medical Co., Ltd. Weihai Shandong Contract manufacturer 8

Record

Regulatory record for Swan-Ganz VIP
Listed by Edwards Lifesciences Technology Sarl, United States
FDA product code DYG
Device type Catheter, Flow Directed
Device class Class 2
Regulation 21 CFR 870.1240
Establishment Contract manufacturer, Specification developer, Manufacturer
510(k) K160084
Record published 2016-09-03
Record revised 2025-05-20 (version 7)

Specifications

Specifications
MRI safety MR Unsafe
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Latex Contains natural rubber latex
Label carries lot or batch number, expiry date, manufacturing date
Storage Special storage condition: STORE IN A COOL, DRY PLACE.
Packaging Shipper of 5, pack of 5, case of 5

Catalogue Numbers

Catalogue numbers for Swan-Ganz VIP
Catalogue number Size Status
831F75 EXTERIOR DIAMETER: 7.5 F (2.5MM), USABLE LENGTH: 110 CM, RECOMMENDED GUIDEWIRE SIZE: 0.025 IN (0.64 MM), MINIMUM INTRODUCER SIZE: 8.5 F (2.8 MM) In distribution
834F75 USABLE LENGTH: 110CM, EXTERIOR DIAMETER: 7.5F (2.5MM), MINIMUM INTRODUCER SIZE: 8.5F (2.8MM), RECOMMENDED GUIDEWIRE SIZE: 0.025 IN (0.64MM) In distribution
831F75 EXTERIOR DIAMETER: 7.5 F (2.5MM), USABLE LENGTH: 110 CM, RECOMMENDED GUIDEWIRE SIZE: 0.025 IN (0.64 MM), MINIMUM INTRODUCER SIZE: 8.5 F (2.8 MM) In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Arrow Teleflex Medical LLC 115
Transonic Transonic Systems, Inc. 12
Corodyn B. Braun Medical Inc. 10
Venos Occlusion Balloon Catheter Oscor Inc. 9
Swan-Ganz True Size Edwards Lifesciences Technology Sarl 9
Graftmaster Abbott Vascular 9
Swan-Ganz Edwards Lifesciences Technology Sarl 7
Pruitt Occlusion Catheter Lemaitre Vascular, Inc. 6
Swan-Ganz Becton, Dickinson AND Company 3
Swan Ganz Catheter Edwards Lifesciences Technology Sarl 2
Swan-Ganz Ccombo Edwards Lifesciences Technology Sarl 2
Cook Cook Incorporated 2

Showing 12 of 23. All products under Catheter, Flow Directed

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K242451 2024-12-09
K233983 2024-06-27
K233824 2024-06-06
K193466 2020-02-16
K160084 2016-05-03

Recalls Naming This Product

5 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Swan-Ganz VIP
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Becton, Dickinson AND Company 510(k) number 2026-04-08 Class II Process change control Catheters may, due to a manufacturing process and material changes, leak/break from the (blue) proximal injectate lumen hub, which may lead to infection, medication loss, and/or blood loss. 183
Edwards Lifesciences Technology Sarl 510(k) number 2018-12-21 Class I Nonconforming Material/Component These Swan Ganz catheters have incorrect lumen assembly, which causes reversal of the lumens. If the lumens are reversed the clinician may note reverse PA and CVP pressure values and waveforms. 277 units 2023-11-02
Edwards Lifesciences Technology Sarl 510(k) number 2018-12-21 Class I Nonconforming Material/Component These Swan Ganz catheters have incorrect lumen assembly, which causes reversal of the lumens. If the lumens are reversed the clinician may note reverse PA and CVP pressure values and waveforms. 875 units 2023-11-02
Edwards Lifesciences Technology Sarl 510(k) number 2018-12-21 Class I Nonconforming Material/Component These Swan Ganz catheters have incorrect lumen assembly, which causes reversal of the lumens. If the lumens are reversed the clinician may note reverse PA and CVP pressure values and waveforms. 9 units 2023-11-02
Edwards Lifesciences Technology Sarl 510(k) number 2018-12-21 Class I Nonconforming Material/Component These Swan Ganz catheters have incorrect lumen assembly, which causes reversal of the lumens. If the lumens are reversed the clinician may note reverse PA and CVP pressure values and waveforms. 459 units 2023-11-02

Recalls

12 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2023-02-14 Class II Packaging process control There is a potential that the distal end of the catheter may be bent beyond its intended curvature and when connected to patient monitoring device, the monitor may display an error message. 59,094 units
2023-02-14 Class II Packaging process control There is a potential that the distal end of the catheter may be bent beyond its intended curvature and when connected to patient monitoring device, the monitor may display an error message. 326 units
2015-05-05 Class II Process control The product failed to meet the internal established statistical test requirement for heparin activity. 978 2016-10-17
2012-05-11 Class II Process control The device is being recalled because the firm received multiple complaints related to passage of a J-tip guidewire when inserted through the distal lumen hub of the catheter. 32,145 units for all products in Recall Event 2014-06-17
2012-05-11 Class II Process control The device is being recalled because the firm received multiple complaints related to passage of a J-tip guidewire when inserted through the distal lumen hub of the catheter. 32,145 units for all products in Recall Event 2014-06-17
2012-05-11 Class II Process control The device is being recalled because the firm received multiple complaints related to passage of a J-tip guidewire when inserted through the distal lumen hub of the catheter. 32,145 units for all products in Recall Event 2014-06-17
2012-05-11 Class II Process control The device is being recalled because the firm received multiple complaints related to passage of a J-tip guidewire when inserted through the distal lumen hub of the catheter. 32,145 units for all products in Recall Event 2014-06-17
2012-05-11 Class II Process control The device is being recalled because the firm received multiple complaints related to passage of a J-tip guidewire when inserted through the distal lumen hub of the catheter. 32,145 units for all products in Recall Event 2014-06-17
2012-05-11 Class II Process control The device is being recalled because the firm received multiple complaints related to passage of a J-tip guidewire when inserted through the distal lumen hub of the catheter. 32,145 units for all products in Recall Event 2014-06-17
2012-05-11 Class II Process control The device is being recalled because the firm received multiple complaints related to passage of a J-tip guidewire when inserted through the distal lumen hub of the catheter. 32,145 units for all products in Recall Event 2014-06-17
2012-05-11 Class II Process control The device is being recalled because the firm received multiple complaints related to passage of a J-tip guidewire when inserted through the distal lumen hub of the catheter. 32,145 units for all products in Recall Event 2014-06-17
2012-05-11 Class II Process control The device is being recalled because the firm received multiple complaints related to passage of a J-tip guidewire when inserted through the distal lumen hub of the catheter. 32,145 units for all products in Recall Event 2014-06-17
2009-02-09 Not classified Software design Cardiac output measurements were unavailable and the following message is displayed in the Vigilance monitor: “Fault. CCO Catheter Verification. Use Bolus Mode”. 5,756 units 2011-04-11
2009-02-09 Not classified Software design Cardiac output measurements were unavailable and the following message is displayed in the Vigilance monitor: “Fault. CCO Catheter Verification. Use Bolus Mode”. 2,091units 2011-04-11
2009-02-09 Not classified Software design Cardiac output measurements were unavailable and the following message is displayed in the Vigilance monitor: “Fault. CCO Catheter Verification. Use Bolus Mode”. 37 units 2011-04-11
2006-11-27 Not classified Other Misbranding-One lot of Swan-Ganz Thermodilution VIP Catheters, Model 831HF75, lot 246HC197 was labeled with different model information (831F75) on the edge label. The edge label states the model is 831F75 which incorrectly indicates that 1,110 units 2012-01-23
2006-06-21 Not classified Other Edwards Lifesciences Vigilance monitors with software release 5.3 or earlier may improperly cause the monitor to deliver power to the Continuous Cardiac Output (CCO) catheter without alerting the user to this situation. This can result in 8305 2008-08-07

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer