03 Sensor Rs02 Large Adhesive Sensor
Catalogue number 3756, listed by Masimo Corporation, United States, under Oximeter, Tissue Saturation. 5 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (2), Jiangsu (2), Sichuan (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Jiangyin Sinbon Electronics Co Ltd | Jiangyin | Jiangsu | Contract manufacturer | 13 |
| Measurement Specialties Chengdu | Chengdu | Sichuan | Contract manufacturer | 3 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
Record
| Listed by | Masimo Corporation, United States |
|---|---|
| FDA product code | MUD |
| Device type | Oximeter, Tissue Saturation |
| Device class | Class 2 |
| Regulation | 21 CFR 870.2700 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| Record published | 2017-10-12 |
| Record revised | 2018-12-03 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 3756 | 20 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Invos | Covidien LP | 54 |
| Nonin | Nonin Medical, Inc. | 30 |
| Fore-Sight Elite® | Cas Medical Systems, Inc. | 12 |
| Fore-Sight® | Cas Medical Systems, Inc. | 9 |
| ForeSight | Edwards Lifesciences Technology Sarl | 7 |
| Spectros T-Stat | Spectros Corporation | 7 |
| Component Neuromonitoring System | Moberg Research, Inc. | 6 |
| HyperView | Hypermed Imaging, Inc. | 6 |
| O3 | Masimo Corporation | 5 |
| Mespere | Mespere Lifesciences Inc. | 3 |
| SnapshotNIR | Kent Imaging Inc | 2 |
| Moor Instruments Ltd | Moor Instruments Ltd. | 2 |
Showing 12 of 30. All products under Oximeter, Tissue Saturation
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K243324 | 2025-07-17 |
| K214072 | 2022-05-06 |
| K201432 | 2020-08-29 |
| K182429 | 2019-06-07 |
| K162603 | 2017-05-26 |
| K160526 | 2016-06-09 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.