Indigo™
BUR 31130884 Indigo RND Fine Dmnd 0.8MM
2manufacturers in China registered for this device type
8catalogue numbers in this listing
Who Else Makes It
Concentrated in Shanghai (1), Guangdong (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Guangdong Jinme Medical Technology Co., Ltd. | Foshan | Guangdong | Manufacturer | 13 |
Record
| Listed by | Medtronic Powered Surgical Solutions, United States |
|---|---|
| FDA product code | ERL |
| Device type | Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece |
| Device class | Class 2 |
| Regulation | 21 CFR 874.4250 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K111520 |
| Record published | 2016-04-08 |
| Record revised | 2018-07-06 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number |
| Sizes | Outer diameter 0.5 to 6 mm |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 31130884 | Outer Diameter 0.8 mm | In distribution |
| 31142080 | Outer Diameter 2.0 mm | In distribution |
| 31142579 | Outer Diameter 2.5 mm | In distribution |
| 31143079 | Outer Diameter 3.0 mm | In distribution |
| 31141583 | Outer Diameter 1.5 mm | In distribution |
| 31146063 | Outer Diameter 6.0 mm | In distribution |
| 31133079 | Outer Diameter 3.0 mm | In distribution |
| 31140584 | Outer Diameter 0.5 mm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| ENT MR8 | Medtronic Powered Surgical Solutions | 234 |
| Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece | Anspach Effort, The | 214 |
| Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece | Karl Storz GmbH & Co. KG | 208 |
| Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece | Synthes Gmbh | 126 |
| Midas Rex | Medtronic Powered Surgical Solutions | 97 |
| Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece | Stryker GmbH | 87 |
| Midas REX Microsaws | Medtronic Powered Surgical Solutions | 75 |
| Piezomed Pro Accessory | W&H Dentalwerk Bürmoos GmbH | 50 |
| Midas Rex Clearview™ | Medtronic Xomed, Inc. | 47 |
| Zethon | Zethon Ltd | 39 |
| NSK Sterile Burs/Drills | Nakanishi Inc. | 34 |
| Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece | Medtronic Xomed, Inc. | 29 |
Showing 12 of 169. All products under Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Medtronic Xomed, Inc. | 510(k) number | 2025-07-17 | Class II | Process change control | Due to out of the box wobble of the driver. | 214 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.