Anatomical Shoulder™ Fracture

Humeral Fracture Stem Ø8-110 - slim

Registry build 21.09.26
8manufacturers in China registered for this device type
6catalogue numbers in this listing
1510(k) clearance
3recalls on this code

Who Else Makes It

Concentrated in Shanghai (3), Jiangsu (3), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HSD
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34

Record

Regulatory record for Anatomical Shoulder™ Fracture
Listed by Zimmer, Inc., United States
FDA product code HSD
Device type Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented
Device class Class 2
Regulation 21 CFR 888.3690
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K142403
Record published 2017-07-27
Record revised 2019-10-14 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date
Sizes Outer diameter 8 to 52 mm; length 110 to 200 mm

Catalogue Numbers

Catalogue numbers for Anatomical Shoulder™ Fracture
Catalogue number Size Status
01.04217.173 Outer Diameter 17 mm In distribution
01.04207.153 Outer Diameter 15 mm In distribution
01.04207.084 Length 110 mm In distribution
01.04227.523 Outer Diameter 52 mm In distribution
01.04217.093 Outer Diameter 9 mm In distribution
01.04207.183 Length 130 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Equinoxe Exactech, Inc. 345
SMR Shoulder Limacorporate 182
FX V135 Fx Shoulder Solutions SAS 127
Acumed Acumed LLC 112
Promos Smith & Nephew, Inc. 104
Trabecular Metal® Zimmer, Inc. 90
Bigliani/Flatow® Zimmer, Inc. 86
Comprehensive® Shoulder System Biomet Orthopedics 85
Arthrex® Arthrex, Inc. 75
SMR System Limacorporate 72
DJO Surgical Encore Medical, L.P. 70
Humeris Shoulder Fx Solutions 69

Showing 12 of 241. All products under Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K161620 2016-11-01

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Anatomical Shoulder™ Fracture
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Zimmer, Inc. 510(k) number 2016-05-17 Class II Device Design In some cases it has been difficult or not possible to disassemble the adjusted Dome Centric from the AS Humeral Rasp after initial positioning of the AS Humeral Trial Head which resulted in the whole construct of the Dome Centric with the 177 2016-10-31

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2013-06-11 Class II Packaging process control The firm is initiating a removal of one lot of the Bigliani/Flatow Humeral Provisional Stem (00-4301-012-17, lot 62283991) as the stems manufactured under the lot are 14mm x 170mm devices incorrectly etched and packaged as 12mm x 170mm devi 1 2014-01-30
2009-09-17 Not classified Other Some of the devices may possess a taper which will not mate with the humeral head, as intended. 12 2009-12-22
2009-09-17 Not classified Other Some of the devices may possess a taper which will not mate with the humeral head, as intended. 12 2009-12-22

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer