Bigliani/Flatow® Trabecular Metal®

11 catalogue numbers from 4307-74, listed by Zimmer, Inc., United States, under Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented. 8 manufacturers in China are registered for this product code.

Registry build 21.09.26
8manufacturers in China registered for this device type
11catalogue numbers in this listing
1510(k) clearance
3recalls on this code

Who Else Makes It

Concentrated in Shanghai (3), Jiangsu (3), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HSD
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34

Record

Regulatory record for Bigliani/Flatow® Trabecular Metal®
Listed by Zimmer, Inc., United States
FDA product code HSD
Device type Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented
Device class Class 2
Regulation 21 CFR 888.3690
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K103404
Record published 2016-07-28
Record revised 2023-05-03 (version 9)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for Bigliani/Flatow® Trabecular Metal®
Catalogue number Size Status
4307-74 In distribution
00-4327-032-52 52 mm In distribution
4307-32-40 40 mm Drill Guide In distribution
4307-62 In distribution
4307-43 2.5 mm Offset In distribution
4307-32-46 46 mm Drill Guide In distribution
4307-35-46 46 mm Impactor In distribution
47-4307-41 2 mm In distribution
00-4327-052-56 56 mm Diameter In distribution
00-4327-046-40 40 mm Diameter In distribution
4307-32-52 52 mm Drill Guide In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Equinoxe Exactech, Inc. 345
SMR Shoulder Limacorporate 182
FX V135 Fx Shoulder Solutions SAS 127
Acumed Acumed LLC 112
Promos Smith & Nephew, Inc. 104
Trabecular Metal® Zimmer, Inc. 90
Bigliani/Flatow® Zimmer, Inc. 86
Comprehensive® Shoulder System Biomet Orthopedics 85
Arthrex® Arthrex, Inc. 75
SMR System Limacorporate 72
DJO Surgical Encore Medical, L.P. 70
Humeris Shoulder Fx Solutions 69

Showing 12 of 241. All products under Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K161620 2016-11-01

Recalls Naming This Product

2 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Bigliani/Flatow® Trabecular Metal®
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Zimmer, Inc. 510(k) number 2013-06-11 Class II Packaging process control The firm is initiating a removal of one lot of the Bigliani/Flatow Humeral Provisional Stem (00-4301-012-17, lot 62283991) as the stems manufactured under the lot are 14mm x 170mm devices incorrectly etched and packaged as 12mm x 170mm devi 1 2014-01-30
Zimmer, Inc. 510(k) number 2012-05-12 Class II Mixed-up of materials/components Bigliani/Flatow The Complete Shoulder Solution Trabecular Metal Glenoid Instrument Drill with Stop, 6 mm. Catalog number 47-4301-031-00 was actually packaged and labeled as catalog number 47-4307-031-00, lot 62071190. 87 units 2013-09-12

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2009-09-17 Not classified Other Some of the devices may possess a taper which will not mate with the humeral head, as intended. 12 2009-12-22
2009-09-17 Not classified Other Some of the devices may possess a taper which will not mate with the humeral head, as intended. 12 2009-12-22

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer