Comprehensive® Instruments

11 catalogue numbers from 010001799, listed by Biomet Orthopedics, United States, under Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented. 8 manufacturers in China are registered for this product code.

Registry build 21.09.26
8manufacturers in China registered for this device type
11catalogue numbers in this listing
1510(k) clearance

Who Else Makes It

Concentrated in Shanghai (3), Jiangsu (3), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HSD
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34

Record

Regulatory record for Comprehensive® Instruments
Listed by Biomet Orthopedics, United States
FDA product code HSD
Device type Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented
Device class Class 2
Regulation 21 CFR 888.3690
510(k) K060694
Record published 2021-03-23
Record revised 2025-05-30 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for Comprehensive® Instruments
Catalogue number Size Status
010001799 Small In distribution
110003474 Medium In distribution
110003486 In distribution
010001792 Large In distribution
110004265 In distribution
110003481 15/64″ In distribution
010001800 Medium In distribution
110003472 Small In distribution
110003476 Large In distribution
110003484 3.2 mm 9″ In distribution
110004203 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Equinoxe Exactech, Inc. 345
SMR Shoulder Limacorporate 182
FX V135 Fx Shoulder Solutions SAS 127
Acumed Acumed LLC 112
Promos Smith & Nephew, Inc. 104
Trabecular Metal® Zimmer, Inc. 90
Bigliani/Flatow® Zimmer, Inc. 86
Comprehensive® Shoulder System Biomet Orthopedics 85
Arthrex® Arthrex, Inc. 75
SMR System Limacorporate 72
DJO Surgical Encore Medical, L.P. 70
Humeris Shoulder Fx Solutions 69

Showing 12 of 241. All products under Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K010827 2001-09-14

Recalls Naming This Product

5 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Comprehensive® Instruments
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Zimmer Orthopedics Manufacturing Limited-Galway 510(k) number 2025-03-03 Class II Nonconforming Material/Component Five complaints received where surgeon was unable to remove and/or connect the inserter with the stem during surgery due to excess material remaining within the taper. Issue may lead to clinically significant extension of surgery to find a 90 US; 136 OUS
Biomet, Inc. 510(k) number 2017-04-26 Class II Under Investigation by firm Zimmer Biomet is conducting a voluntary recall for a single lot of the Modular Hybrid Glenoid Base Large for the Comprehensive Shoulder System after it was determined that two pieces from the lot were moved to finished goods and shipped des 16 2018-03-30
Biomet, Inc. 510(k) number 2017-02-17 Class II Process design Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components. 28,253 in total 2018-01-29
Biomet, Inc. 510(k) number 2008-03-13 Not classified Device Design The glenoid implant may not seat fully on the face of the natural glenoid due to inadequate measurement tolerances (tolerance stack-up) in the design of the cutter. Use of the instrument may lead to incomplete seating of the glenoid implan 189 2008-10-15
Biomet, Inc. 510(k) number 0012-12-06 Class II Nonconforming Material/Component Biomet is recalling Part Number PT-113950 PT Hybrid Glenoid Post, following an investigation which identified that the male thread of the post may be oversized. This oversized condition can vary in degree and may lead to the following thre 1050 2013-11-08

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer