Flex Shoulder System
13 catalogue numbers from DWF343, listed by Tornier Inc., United States, under Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented. 8 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Shanghai (3), Jiangsu (3), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
Record
| Listed by | Tornier Inc., United States |
|---|---|
| FDA product code | HSD |
| Device type | Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3690 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2015-10-16 |
| Record revised | 2026-02-12 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | expiry date, serial number |
| Sizes | Outer diameter 33 to 52 mm; angle 7.5 to 17.5 °; height 16 to 19 mm |
| Distribution end date | 2022-03-30 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| DWF343 | Height 16 mm | Withdrawn |
| DWF395A | Outer Diameter 39 mm | Withdrawn |
| DWF356B | Angle 12.5 ° | Withdrawn |
| DWF356A | Thickness + 6 mm | Withdrawn |
| DWF395C | Outer Diameter 39 mm | Withdrawn |
| DWF357A | Angle 17.5 ° | Withdrawn |
| DWF392C | Thickness +9 mm | Withdrawn |
| DWF392A | Angle 17.5 ° | Withdrawn |
| DWF391A | Angle 17.5 ° | Withdrawn |
| DWF359B | Thickness + 9 mm | Withdrawn |
| DWF346 | Height 17 mm | Withdrawn |
| DWF359C | Thickness +9 mm | Withdrawn |
| DWF352 | Height 19 mm | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Equinoxe | Exactech, Inc. | 345 |
| SMR Shoulder | Limacorporate | 182 |
| FX V135 | Fx Shoulder Solutions SAS | 127 |
| Acumed | Acumed LLC | 112 |
| Promos | Smith & Nephew, Inc. | 104 |
| Trabecular Metal® | Zimmer, Inc. | 90 |
| Bigliani/Flatow® | Zimmer, Inc. | 86 |
| Comprehensive® Shoulder System | Biomet Orthopedics | 85 |
| Arthrex® | Arthrex, Inc. | 75 |
| SMR System | Limacorporate | 72 |
| DJO Surgical | Encore Medical, L.P. | 70 |
| Humeris Shoulder | Fx Solutions | 69 |
Showing 12 of 241. All products under Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K062661 | 2006-12-22 |
| K063081 | 2006-11-09 |
| K011942 | 2001-07-13 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.