Tornier HRS Max
Reamer Planer
8manufacturers in China registered for this device type
10catalogue numbers in this listing
3510(k) clearances naming this product code
Who Else Makes It
Concentrated in Shanghai (3), Jiangsu (3), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
Record
| Listed by | Tornier Inc., United States |
|---|---|
| FDA product code | HSD |
| Device type | Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3690 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K251686 |
| Record published | 2025-11-19 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date, serial number |
| Sizes | Outer diameter 9 to 19 mm; length 30 to 100 mm |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| ARS1024312 | Size: 12 | In distribution |
| ARS1040730 | Length 30 mm | In distribution |
| ARS1040614 | Size: 14 | In distribution |
| ARS1040619 | Size: 19 | In distribution |
| ARS1024319 | Outer Diameter 19 mm | In distribution |
| ARS10407100 | Length 100 mm | In distribution |
| ARS1024309 | Size: 9 | In distribution |
| ARS1024316 | Outer Diameter 16 mm | In distribution |
| ARS1040615 | Size: 15 | In distribution |
| ARS1024317 | Outer Diameter 17 mm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Equinoxe | Exactech, Inc. | 345 |
| SMR Shoulder | Limacorporate | 182 |
| FX V135 | Fx Shoulder Solutions SAS | 127 |
| Acumed | Acumed LLC | 112 |
| Promos | Smith & Nephew, Inc. | 104 |
| Trabecular Metal® | Zimmer, Inc. | 90 |
| Bigliani/Flatow® | Zimmer, Inc. | 86 |
| Comprehensive® Shoulder System | Biomet Orthopedics | 85 |
| Arthrex® | Arthrex, Inc. | 75 |
| SMR System | Limacorporate | 72 |
| DJO Surgical | Encore Medical, L.P. | 70 |
| Humeris Shoulder | Fx Solutions | 69 |
Showing 12 of 241. All products under Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K062661 | 2006-12-22 |
| K063081 | 2006-11-09 |
| K011942 | 2001-07-13 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Tornier Inc. | 510(k) number | 2026-03-05 | Class II | Labeling design | Affected products were incorrectly labeled as Tornier HRS Max products. These parts are compatible with the Tornier HRS system only, and are incompatible with the Tornier HRS Max system. | 233 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.