AS Vega System® PS

AS Vega PS Femoral Comp.cemented F6N L

Registry build 21.09.26
21manufacturers in China registered for this device type
37catalogue numbers in this listing
6510(k) clearances naming this product code
8recalls on this code

Who Else Makes It

Concentrated in Jiangsu (10), Shanghai (4), Beijing (3). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JWH
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Changzhou Wastonortho Medical Appliance Co., Ltd. Changzhou Jiangsu Contract manufacturer 5

Showing 12 of 21. All 21 manufacturers in China registered for Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

Record

Regulatory record for AS Vega System® PS
Listed by Aesculap AG, Germany
FDA product code JWH
Device type Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3560
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Record published 2015-09-24
Record revised 2025-11-13 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Distribution end date 2025-01-22

Catalogue Numbers

Catalogue numbers for AS Vega System® PS
Catalogue number Size Status
NX059Z Implant Fixation : cemented Withdrawn
NX016Z Implant Fixation : cemented Withdrawn
NX053Z Figure/Size : T2 Withdrawn
NX049Z Implant Fixation : cemented Withdrawn
NX013Z Implant Fixation : cemented Withdrawn
NX004Z Implant Fixation : cemented Withdrawn
NX054Z Implant Fixation : cemented Withdrawn
NX032Z Implant Fixation : cemented Withdrawn
NX014Z Left/Right : left Withdrawn
NX027Z Implant Fixation : cemented Withdrawn
NX018Z Implant Fixation : cemented Withdrawn
NX030Z Implant Fixation : cemented Withdrawn
NX009Z Implant Fixation : cemented Withdrawn
NX029Z Implant Fixation : cemented Withdrawn
NX024Z Implant Fixation : cemented Withdrawn
NX010Z Implant Fixation : cemented Withdrawn
NX057Z Implant Fixation : cemented Withdrawn
NX038Z Implant Fixation : cemented Withdrawn
NX005Z Implant Fixation : cemented Withdrawn
NX008Z Implant Fixation : cemented Withdrawn
NX028Z Implant Fixation : cemented Withdrawn
NX012Z Implant Fixation : cemented Withdrawn
NX036Z Implant Fixation : cemented Withdrawn
NX051Z Implant Fixation : cemented Withdrawn
NX006Z Implant Fixation : cemented Withdrawn
NX033Z Implant Fixation : cemented Withdrawn
NX007Z Implant Fixation : cemented Withdrawn
NX055Z Implant Fixation : cemented Withdrawn
NX026Z Implant Fixation : cemented Withdrawn
NX050Z Implant Fixation : cemented Withdrawn
NX031Z Implant Fixation : cemented Withdrawn
NX011Z Implant Fixation : cemented Withdrawn
NX058Z Implant Fixation : cemented Withdrawn
NX034Z Implant Fixation : cemented Withdrawn
NX052Z Implant Fixation : cemented Withdrawn
NX056Z Implant Fixation : cemented Withdrawn
NX025Z Implant Fixation : cemented Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Prophecy® Microport Orthopedics Inc. 4,423
Exult Knee Replacement System Corentec Co., Ltd. 1,770
Freedom Maxx Orthopedics Inc. 1,693
Legion Smith & Nephew, Inc. 1,534
MyKnee Medacta International SA 1,466
Journey Smith & Nephew, Inc. 1,339
Persona® Zimmer, Inc. 1,254
DJO Surgical Encore Medical, L.P. 1,131
U2 Total Knee System United Orthopedic Corp. 1,078
CKS Plus Shalby Advanced Technologies, Inc. 1,024
Lospa Modular Knee System Corentec Co., Ltd. 1,020
Natural-Knee® Zimmer, Inc. 980

Showing 12 of 1,175. All products under Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K053579 2006-05-17
K053390 2006-02-06
K030367 2003-08-21
K023788 2002-12-13
K022672 2002-11-08
K021313 2002-07-22

Recalls

8 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2020-01-21 Class II Material/Component Contamination Low Density Polyethylene (LDPE) particles may be present on the surface of the implant upon the opening of the inner packaging. 2021-09-22
2020-01-21 Class II Material/Component Contamination Low Density Polyethylene (LDPE) particles may be present on the surface of the implant upon the opening of the inner packaging. 2021-09-22
2020-01-21 Class II Material/Component Contamination Low Density Polyethylene (LDPE) particles may be present on the surface of the implant upon the opening of the inner packaging. 24010 2021-09-22
2020-01-21 Class II Material/Component Contamination Low Density Polyethylene (LDPE) particles may be present on the surface of the implant upon the opening of the inner packaging. 2021-09-22
2020-01-21 Class II Material/Component Contamination Low Density Polyethylene (LDPE) particles may be present on the surface of the implant upon the opening of the inner packaging. 2021-09-22
2015-11-30 Class II Packaging change control Aesculap Inc. US has initiated a recall on Tibial and Femur extension sterile pressfit stem implant packaging that are used for Columbus Revision/Enduro Knee Implants because it is labeled as Cementless. US product is indicated in the US fo 1232 2016-10-13
2013-09-19 Class II Component change control The Columbus Revision CoCr 15 mm distal and posterior implant spacers, sizes F5-F7, were not compatible. 24 2014-12-22
2012-02-21 Class II Nonconforming Material/Component During an internal quality inspection, the tibia plateau was found to be out of specification. There is a potential for misalignment between the tibia plateau and attachment of the extension stem. 8 2014-01-15

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer