Biomet®

50 catalogue numbers from 32-341641, listed by Biomet Orthopedics, United States, under Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer. 21 manufacturers in China are registered for this product code.

Registry build 21.09.26
21manufacturers in China registered for this device type
50catalogue numbers in this listing
2510(k) clearances naming this product code

Who Else Makes It

Concentrated in Jiangsu (10), Shanghai (4), Beijing (3). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JWH
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Changzhou Wastonortho Medical Appliance Co., Ltd. Changzhou Jiangsu Contract manufacturer 5

Showing 12 of 21. All 21 manufacturers in China registered for Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

Record

Regulatory record for Biomet®
Listed by Biomet Orthopedics, United States
FDA product code JWH
Device type Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3560
510(k) K121149
Record published 2022-06-22
Record revised 2025-05-30 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number, manufacturing date

Catalogue Numbers

Catalogue numbers for Biomet®
Catalogue number Size Status
32-341641 21 mm X 200 mm In distribution
32-341634 14 mm X 200 mm In distribution
32-341664 24 mm X 120 mm In distribution
32-341692 12 mm X 160 mm In distribution
32-148149 19 mm X 40 mm In distribution
32-341659 19 mm X 120 mm In distribution
32-341692 12 mm X 160 mm In distribution
32-341694 14 mm X 160 mm In distribution
32-341639 19 mm X 200 mm In distribution
32-341657 17 mm X 120 mm In distribution
32-341623 23 mm X 80 mm In distribution
32-148153 23 mm X 40 mm In distribution
32-148151 21 mm X 40 mm In distribution
32-341614 14 mm X 80 mm In distribution
32-341638 18 mm X 200 mm In distribution
32-341637 17 mm X 200 mm In distribution
32-341632 12 mm X 200 mm In distribution
32-341642 22 mm X 200 mm In distribution
32-148140 10 mm X 40 mm In distribution
32-341618 18 mm X 80 mm In distribution
32-341616 16 mm X 80 mm In distribution
32-148149 19 mm X 40 mm In distribution
32-341610 10 mm X 80 mm In distribution
32-341620 20 mm X 80 mm In distribution
32-148148 18 mm X 40 mm In distribution
32-341624 24 mm X 80 mm In distribution
32-341658 18 mm X 120 mm In distribution
32-341701 21 mm X 160 mm In distribution
32-341652 12 mm X 120 mm In distribution
32-341617 17 mm X 80 mm In distribution
32-341697 17 mm X 160 mm In distribution
32-341700 20 mm X 160 mm In distribution
32-341699 19 mm X 160 mm In distribution
32-341663 23 mm X 120 mm In distribution
32-341702 22 mm X 160 mm In distribution
32-467355 28 mm X-Small In distribution
32-148147 17 mm X 40 mm In distribution
32-341636 16 mm X 200 mm In distribution
32-148151 21 mm X 40 mm In distribution
32-341654 14 mm X 120 mm In distribution
32-341612 12 mm X 80 mm In distribution
32-341656 16 mm X 120 mm In distribution
32-148153 23 mm X 40 mm In distribution
32-341621 21 mm X 80 mm In distribution
32-341314 10 mm X 40 mm In distribution
32-148152 22 mm X 40 mm In distribution
32-341619 19 mm X 80 mm In distribution
32-341696 16 mm X 160 mm In distribution
32-341661 21 mm X 120 mm In distribution
32-341697 17 mm X 160 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Prophecy® Microport Orthopedics Inc. 4,423
Exult Knee Replacement System Corentec Co., Ltd. 1,770
Freedom Maxx Orthopedics Inc. 1,693
Legion Smith & Nephew, Inc. 1,534
MyKnee Medacta International SA 1,466
Journey Smith & Nephew, Inc. 1,339
Persona® Zimmer, Inc. 1,254
DJO Surgical Encore Medical, L.P. 1,131
U2 Total Knee System United Orthopedic Corp. 1,078
CKS Plus Shalby Advanced Technologies, Inc. 1,024
Lospa Modular Knee System Corentec Co., Ltd. 1,020
Natural-Knee® Zimmer, Inc. 980

Showing 12 of 1,175. All products under Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K080528 2008-06-17
K022586 2002-08-15

Recalls Naming This Product

12 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Biomet®
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Biomet, Inc. 510(k) number 2022-12-29 Class II Labeling Change Control Components Incorrectly labeled as either smaller or larger and incorrect side (right/left). 157 units
Biomet, Inc. 510(k) number 2022-12-29 Class II Labeling Change Control Components Incorrectly labeled as either smaller or larger and incorrect side (right/left). 91 units
Biomet, Inc. 510(k) number 2020-12-01 Class II Process control Incorrect bolt -tibial bolts in package instead of femoral bolts may delay procedure 21 units 2022-07-08
Biomet, Inc. 510(k) number 2018-10-22 Class II Labeling mix-ups Label on the outer carton or the patient labels does not match label on the inner sterile packaging 8 units 2019-12-11
Biomet, Inc. 510(k) number 2018-10-22 Class II Labeling mix-ups Label on the outer carton or the patient labels does not match label on the inner sterile packaging 8 units 2019-12-11
Biomet, Inc. 510(k) number 2018-08-02 Class II Under Investigation by firm The implant only has one bolt in the sterile package but it should have had two. 16 2019-04-25
Biomet, Inc. 510(k) number 2018-08-02 Class II Under Investigation by firm The implant only has one bolt in the sterile package but it should have had two. 16 2019-04-25
Biomet, Inc. 510(k) number 2018-05-24 Class II Under Investigation by firm Two lots of tibial bearings were commingled. There is a possibility that a 14mm tibial bearing is packaged in a box labeled as 12 mm tibial bearing and vice versa. This may lead to extension of surgery to find another implant. 48 2020-04-07
Biomet, Inc. 510(k) number 2018-05-11 Class II Under Investigation by firm The label master file was errantly set up as a 63/37mm instead of a 63/67mm. There is no 63/37 size offered, and the product is laser marked with the correct size. 169 2019-11-21
Biomet, Inc. 510(k) number 2017-10-03 Class II Error in labeling The affected products are labeled as a 62.5mm LEFT Femur; however, the contents are a Vanguard 70mm RIGHT Femur. 8 2018-08-23
Biomet, Inc. 510(k) number 2016-08-08 Class II Process control The drill bit used to drill the hex pre-drilled hole in the screw head of the Tibial Augment Bolts included in the Vanguard 360 Revision Knee System was larger than allowable per the process specification. As a result, the hex geometry can 454 2017-06-05
Biomet, Inc. 510(k) number 2014-07-01 Class II Process change control The Vanguard 360 Femoral Boss Reamers were manufactured oversized to the print. The instrument may not fit into the mating component. 461 2015-10-30

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer