Femoral Component, CR, Cemented

Femoral component, CR, cemented, #4.5, right

Registry build 21.09.26
21manufacturers in China registered for this device type
12catalogue numbers in this listing
20510(k) clearances naming this product code
3recalls on this code

Who Else Makes It

Concentrated in Jiangsu (10), Shanghai (4), Beijing (3). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JWH
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Changzhou Wastonortho Medical Appliance Co., Ltd. Changzhou Jiangsu Contract manufacturer 5

Showing 12 of 21. All 21 manufacturers in China registered for Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

Record

Regulatory record for Femoral component, CR, cemented
Listed by United Orthopedic Corp., Taiwan
FDA product code JWH
Device type Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3560
Establishment Contract manufacturer, Manufacturer, Exporter
510(k) K150829
Record published 2015-12-04
Record revised 2018-07-25 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for Femoral component, CR, cemented
Catalogue number Size Status
2103-1445 #4.5 In distribution
2103-1335 #3.5 In distribution
2103-1415 #1.5 In distribution
2103-1425 #2.5 In distribution
2103-1455 #5.5 In distribution
2103-1315 #1.5 In distribution
2103-1345 #4.5 In distribution
2103-1365 #6.5 In distribution
2103-1355 #5.5 In distribution
2103-1325 #2.5 In distribution
2103-1435 #3.5 In distribution
2103-1465 #6.5 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Prophecy® Microport Orthopedics Inc. 4,423
Exult Knee Replacement System Corentec Co., Ltd. 1,770
Freedom Maxx Orthopedics Inc. 1,693
Legion Smith & Nephew, Inc. 1,534
MyKnee Medacta International SA 1,466
Journey Smith & Nephew, Inc. 1,339
Persona® Zimmer, Inc. 1,254
DJO Surgical Encore Medical, L.P. 1,131
U2 Total Knee System United Orthopedic Corp. 1,078
CKS Plus Shalby Advanced Technologies, Inc. 1,024
Lospa Modular Knee System Corentec Co., Ltd. 1,020
Natural-Knee® Zimmer, Inc. 980

Showing 12 of 1,175. All products under Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K252725 2025-09-25
K243024 2024-12-20
K222700 2022-10-06
K210961 2021-04-21
K161705 2017-03-16
K161360 2017-02-01
K152430 2016-04-12
K150829 2015-09-25
K140073 2014-06-16
K132752 2014-03-13
K131864 2014-01-15
K131116 2013-10-30
K122183 2013-02-05
K120507 2012-05-04
K103733 2011-08-02
K100981 2010-06-14
K082424 2008-12-16
K082469 2008-09-26
K051640 2006-03-01
K021657 2002-08-12

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-05-20 Class II Process design Due to an incomplete process of the component screw by a subcontractor which prevents the properly assembling of stem trail. 2
2017-11-24 Class II Labeling mix-ups UOC received a customer compliant report from our distributor on October 31, 2017
which stated that contents of the package do not match the product labeling.
14 pieces 2018-10-09
2017-11-24 Class II Labeling mix-ups UOC received a customer compliant report from our distributor on October 31, 2017
which stated that contents of the package do not match the product labeling.
69 pieces 2018-10-09

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer