Genesis II

Genesis II Cruciate Retaining ALL Polyethylene Tibial Baseplate Size 6 13MM Right

Registry build 21.09.26
21manufacturers in China registered for this device type
851catalogue numbers in this listing
49510(k) clearances naming this product code
40recalls on this code

Who Else Makes It

Concentrated in Jiangsu (10), Shanghai (4), Beijing (3). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JWH
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Changzhou Wastonortho Medical Appliance Co., Ltd. Changzhou Jiangsu Contract manufacturer 5

Showing 12 of 21. All 21 manufacturers in China registered for Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

Record

Regulatory record for Genesis II
Listed by Smith & Nephew, Inc., United States
FDA product code JWH
Device type Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3560
Establishment Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K951987
Record published 2015-09-28
Record revised 2025-12-11 (version 10)

Specifications

Specifications
MRI safety MR Conditional
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date
Storage Special storage condition: : –
Sizes Length 15 to 50 mm; height 9 to 18 mm
Distribution end date 2022-03-17
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Genesis II
Catalogue number Size Per pack Status
71420488 In distribution
71420834 In distribution
71422004 In distribution
71930007 In distribution
71420108 In distribution
71420396 In distribution
71930978 In distribution
71925049 In distribution
71420840 In distribution
71420080 In distribution
71934436 In distribution
71925054 In distribution
71933734 In distribution
71420492 In distribution
71420428 In distribution
71420368 In distribution
71420470 In distribution
71420356 In distribution
71421517 In distribution
71930003 In distribution
71421545 In distribution
71420800 In distribution
71420004 In distribution
71420232 In distribution
71420410 In distribution
71934584 In distribution
71420504 In distribution
71935015 In distribution
71420640 In distribution
71421542 In distribution
71420550 In distribution
71421117 In distribution
71420850 In distribution
71421118 In distribution
71420042 In distribution
71420220 In distribution
71420578 In distribution
71420874 In distribution
71421549 In distribution
71421338 In distribution
71420248 In distribution
71420794 In distribution
71420384 In distribution
71421032 In distribution
71935019 In distribution
71420112 In distribution
71420878 In distribution
71422002 In distribution
71925052 In distribution
71934585 In distribution
71420964 In distribution
71420584 In distribution
71420394 In distribution
71420130 In distribution
71420212 In distribution
71930197 In distribution
71420647 In distribution
71420576 In distribution
71421516 In distribution
71421544 In distribution
71420460 In distribution
71420382 In distribution
71420562 In distribution
71420016 In distribution
71934380 In distribution
71420006 In distribution
71421115 In distribution
71935017 In distribution
71420252 In distribution
71420886 In distribution
71933789 In distribution
71420560 In distribution
71420236 In distribution
71421015 In distribution
71420166 In distribution
71420542 In distribution
71420999 2 In distribution
71421029 In distribution
71420960 In distribution
71420422 In distribution
71420444 In distribution
71420788 In distribution
71420534 In distribution
71934431 In distribution
71420222 In distribution
71933717 In distribution
71420742 In distribution
71420000 In distribution
71421506 In distribution
71420568 In distribution
71421038 In distribution
71420730 In distribution
71420406 In distribution
71420586 In distribution
71420824 In distribution
71420514 Size: Size 7-8 In distribution
71420580 In distribution
71930976 In distribution
71420582 In distribution
71420254 In distribution
71436392 In distribution
71436385 In distribution
71421328 In distribution
71420798 In distribution
71421112 In distribution
71930977 In distribution
71436386 In distribution
71420770 In distribution
71421510 In distribution
71420976 Diameter: 6.5 mm In distribution
71436396 In distribution
XK000557-1 In distribution
71420450 In distribution
71420034 In distribution
71420088 In distribution
71420224 In distribution
71933742 In distribution
71420296 In distribution
71924905 In distribution
71420518 Size: Size 7-8 In distribution
71436395 In distribution
71927686 In distribution
71420240 In distribution
71420140 In distribution
71933710 In distribution
71420170 In distribution
71420474 In distribution
71925053 In distribution
71420870 In distribution
71420564 In distribution
71925047 In distribution
71420412 In distribution
71933733 In distribution
71421322 In distribution
71932634 In distribution
71420008 In distribution
71420360 In distribution
71420064 In distribution
71420244 In distribution
71420494 In distribution
71933741 In distribution
71421551 In distribution
71933708 In distribution
71421546 In distribution
71421535 In distribution
71420194 In distribution
71420070 In distribution
71420250 In distribution
71420234 In distribution
71420332 In distribution
71420434 In distribution
71933739 In distribution
71420836 In distribution
71421507 In distribution
71420246 In distribution
71421016 In distribution
71420962 In distribution
71420768 In distribution
71420374 In distribution
71933716 In distribution
71926239 In distribution
71420126 In distribution
71421523 In distribution
71420148 In distribution
71420792 In distribution
71420776 In distribution
71421332 In distribution
71420970 In distribution
71420774 In distribution
71420354 In distribution
71930194 In distribution
71934389 In distribution
71420188 In distribution
71420826 In distribution
71420302 In distribution
71421035 In distribution
E0015302-1 In distribution
71420060 In distribution
71420732 In distribution
71436398 In distribution
71935013 In distribution
71420062 In distribution
71421509 In distribution
71420734 In distribution
71420330 In distribution
71436381 In distribution
XK000734-2 In distribution
71926238 In distribution
71436394 In distribution
71421522 In distribution
71430438 In distribution
71421518 In distribution
71420638 In distribution
71421536 In distribution
71926224 In distribution
71420574 In distribution
71934382 In distribution
71420390 In distribution
71420778 In distribution
71420634 In distribution
71934386 In distribution
71420994 In distribution
71421312 In distribution
71935011 In distribution
71420258 In distribution
71420086 In distribution
71420758 In distribution
71934379 In distribution
71420018 In distribution
71421533 In distribution
71420498 In distribution
71420362 In distribution
71421504 In distribution
71421013 In distribution
71925055 In distribution
71420818 In distribution
71420358 In distribution
71420094 In distribution
71420202 In distribution
71420380 In distribution
71420318 In distribution
71420816 In distribution
71933280 In distribution
71420812 In distribution
71421501 In distribution
71420218 In distribution
71933715 In distribution
71420388 In distribution
71421316 In distribution
71933713 In distribution
71420524 In distribution
71420418 In distribution
71420852 In distribution
71420466 In distribution
71420526 In distribution
71420740 In distribution
71420426 In distribution
71931716 In distribution
71420350 In distribution
71420530 In distribution
71421543 In distribution
71420120 In distribution
71926221 In distribution
71420026 In distribution
71420204 In distribution
71933738 In distribution
71420020 In distribution
71421521 In distribution
71420160 In distribution
71436387 In distribution

Showing 250 of 300 catalogue numbers.

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Prophecy® Microport Orthopedics Inc. 4,423
Exult Knee Replacement System Corentec Co., Ltd. 1,770
Freedom Maxx Orthopedics Inc. 1,693
Legion Smith & Nephew, Inc. 1,534
MyKnee Medacta International SA 1,466
Journey Smith & Nephew, Inc. 1,339
Persona® Zimmer, Inc. 1,254
DJO Surgical Encore Medical, L.P. 1,131
U2 Total Knee System United Orthopedic Corp. 1,078
CKS Plus Shalby Advanced Technologies, Inc. 1,024
Lospa Modular Knee System Corentec Co., Ltd. 1,020
Natural-Knee® Zimmer, Inc. 980

Showing 12 of 1,175. All products under Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K250677 2025-04-02
K230653 2023-05-04
K230555 2023-03-30
K221939 2022-07-26
K220896 2022-04-26
K211671 2021-08-17
K200227 2020-06-04
K200826 2020-04-24
K200407 2020-03-13
K183010 2018-11-28
K180334 2018-03-05
K172336 2018-01-10
K173331 2017-11-16
K170282 2017-05-22
K170648 2017-05-11
K162775 2017-01-13
K150241 2015-10-27
K152726 2015-10-21
K143226 2015-02-12
K142807 2014-12-22
K141471 2014-11-14
K141585 2014-08-21
K140555 2014-05-29
K130708 2013-12-11
K123159 2013-05-03
K121443 2012-08-13
K120698 2012-05-18
K113482 2012-02-27
K112941 2011-12-20
K111711 2011-09-16
K110837 2011-04-22
K101499 2010-08-26
K093746 2010-04-14
K091014 2009-09-29
K082358 2008-11-25
K072531 2007-12-06
K072858 2007-11-20
K071071 2007-09-19
K060742 2006-05-03
K051229 2005-07-20
K042515 2005-03-14
K041825 2005-03-11
K043440 2005-02-18
K041106 2004-07-01
K032295 2003-08-21
K030301 2003-02-25
K022010 2002-08-19
K012778 2002-03-15
K002740 2000-11-30

Recalls Naming This Product

15 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Genesis II
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Smith & Nephew, Inc. 510(k) number 2024-10-02 Class II Packaging change control Complaint received indicating that a package contained a LEGION NARROW PS OXIN SZ 5N RIGHT implant instead of a GENESIS II POSTERIOR STABILIZED FEMORAL SIZE 5 LEFT as described on the product label. 5 units
Smith & Nephew, Inc. 510(k) number 2022-06-27 Class II Process control The product was mispackaged (swapped). The devices within the inner tray matches the inner tray but does not match the outer box label and the chart sticks. 31 devices 2026-03-25
Smith & Nephew, Inc. 510(k) number 2020-09-21 Class II Nonconforming Material/Component The anterior locking detail does not meet its design specifications. 47 devices 2026-05-22
Smith & Nephew, Inc. 510(k) number 2020-07-16 Class II Nonconforming Material/Component Due to an inconsistency in the raw material process, specific lots may contain units with internal non-homogenous material defects. 1,845 units
Smith & Nephew, Inc. 510(k) number 2017-09-14 Class II Mixed-up of materials/components The Legion Screw-on Wedge Size 4 contained 5MM screws instead of the required 10MM screw. 10 units 2020-08-21
Smith & Nephew, Inc. 510(k) number 2017-08-01 Class II Employee error Two lots of Genesis II Non Porous C/R Femoral Size 6 right packaged were distributed containing Genesis II C/R Femoral Size 4 left. 27 units 2019-02-19
Smith & Nephew, Inc. 510(k) number 2015-11-09 Class II Process design One lot of 35 mm patella implants is labeled as 32 mm. These implants have pegs which are spaced proportionally; therefore the mismatch prevents the pegs from properly aligning with pre-drilled holes during implantation. 20 units 2016-03-17
Smith & Nephew, Inc. 510(k) number 2013-10-07 Class II Process control Swapped product. Non-porous tibial base size 5 L was mis-packaged as size 6 R and vice versa. 4 units 2016-08-23
Smith & Nephew, Inc. 510(k) number 2013-10-07 Class II Process control Swapped product. Non-porous tibial base size 5 L was mis-packaged as size 6 R and vice versa. 4 units 2016-08-23
Smith & Nephew, Inc. 510(k) number 2013-08-27 Class II Package design/selection The Tyvek(TM) lid on one, or both, of the two trays that form a
double barrier around the insert may not have been adequately sealed.
16 pieces 2019-08-20
Smith & Nephew, Inc. 510(k) number 2013-08-27 Class II Package design/selection The Tyvek(TM) lid on one, or both, of the two trays that form a
double barrier around the insert may not have been adequately sealed.
45 pieces 2019-08-20
Smith & Nephew, Inc. 510(k) number 2013-08-27 Class II Package design/selection The Tyvek(TM) lid on one, or both, of the two trays that form a
double barrier around the insert may not have been adequately sealed.
80 pieces 2019-08-20
Smith & Nephew, Inc. 510(k) number 2013-08-27 Class II Package design/selection The Tyvek(TM) lid on one, or both, of the two trays that form a
double barrier around the insert may not have been adequately sealed.
32 pieces 2019-08-20
Smith & Nephew, Inc. 510(k) number 2013-08-27 Class II Package design/selection The Tyvek(TM) lid on one, or both, of the two trays that form a
double barrier around the insert may not have been adequately sealed.
46 pieces 2019-08-20
Smith & Nephew, Inc. 510(k) number 2013-08-27 Class II Package design/selection The Tyvek(TM) lid on one, or both, of the two trays that form a
double barrier around the insert may not have been adequately sealed.
8 pieces 2019-08-20

Recalls

34 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2024-10-02 Class II Packaging change control Complaint received indicating that a package contained a LEGION NARROW PS OXIN SZ 5N RIGHT implant instead of a GENESIS II POSTERIOR STABILIZED FEMORAL SIZE 5 LEFT as described on the product label. 8 units
2024-10-02 Class II Packaging change control Complaint received indicating that a package contained a LGN OX CONSTRAINED FEM 3 LT implant instead of a LGN OX CONSTRAINED FEM 4 LT as described on the product label. 2 units
2024-10-02 Class II Packaging change control Complaint received indicating that a package contained a LGN OX CONSTRAINED FEM 3 LT implant instead of a LGN OX CONSTRAINED FEM 4 LT as described on the product label. 3 units
2023-09-27 Class II Component change control The JRNY II BCS XLPE ART ISRT SZ 5-6 LT 10MM was laser etched, labeled and packaged as a JRNY II BCS CNSTRD ART ISRT 5-6 LT 10MM. And also, a JRNY II BCS CNSTRD ART ISRT 5-6 LT 10MM was laser etched, labeled and packaged as a JRNY II BCS XL 29 units
2023-09-27 Class II Component change control The JRNY II BCS XLPE ART ISRT SZ 5-6 LT 10MM was laser etched, labeled and packaged as a JRNY II BCS CNSTRD ART ISRT 5-6 LT 10MM. And also, a JRNY II BCS CNSTRD ART ISRT 5-6 LT 10MM was laser etched, labeled and packaged as a JRNY II BCS XL 28 units
2023-08-31 Class II Labeling Change Control The firm conducting a recall due to a complaint received indicating that a package contained a LEGION NARROW PS OXIN SZ 4N LT implant instead of a LEGION NARROW PSvOXIN SZ 5N LT as described on the product label. 8 units
2022-04-19 Class II Nonconforming Material/Component It was reported that a JOURNEY II BCS Femoral OXIN LT SZ5 was in a box labelled as a LEGION NARROW PS OXIN SZ 6N RT. 16 units 2024-08-16
2021-05-19 Class II Nonconforming Material/Component The device components experienced a manufacturing process error that resulted in surface damage from product handling. 5 units 2023-04-14
2019-12-19 Class II Process control LEGION PS High Flex XLPE Articular Insert was packaged with an incorrect part 29 units 2024-09-04
2018-12-10 Class II Device Design Higher than anticipated occurrence of bone fracture during the use of the XR Tibia Posterior Punch 46 units 2020-11-03
2018-12-10 Class II Device Design Higher than anticipated occurrence of bone fracture during the use of the XR Tibia Posterior Punch 65 units 2020-11-03
2018-12-10 Class II Device Design Higher than anticipated occurrence of bone fracture during the use of the XR Tibia Posterior Punch 65 units 2020-11-03
2018-12-10 Class II Device Design Higher than anticipated occurrence of bone fracture during the use of the XR Tibia Posterior Punch 65 units 2020-11-03
2018-06-13 Class II Other The data in the National Joint Registry of England, Wales and Northern Ireland (NJREWNI) and Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) indicate that the first generation JOURNEY BCS Knee System has a r 10,792 units
2018-06-13 Class II Other The data in the National Joint Registry of England, Wales and Northern Ireland (NJREWNI) and Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) indicate that the first generation JOURNEY BCS Knee System has a r 42,050 units
2018-06-13 Class II Other The data in the National Joint Registry of England, Wales and Northern Ireland (NJREWNI) and Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) indicate that the first generation JOURNEY BCS Knee System has a r 64642
2018-03-30 Class II Packaging process control The affected products were inadvertently packaged with the inner packaging pouch being sealed together with the outer pouch. 2019-08-21
2018-03-30 Class II Packaging process control The affected products were inadvertently packaged with the inner packaging pouch being sealed together with the outer pouch. 47 units 2019-08-21
2018-03-30 Class II Packaging process control The affected products were inadvertently packaged with the inner packaging pouch being sealed together with the outer pouch. 72 units 2019-08-21
2018-03-30 Class II Packaging process control The affected products were inadvertently packaged with the inner packaging pouch being sealed together with the outer pouch. 16 units 2019-08-21
2018-01-15 Class II Process control The affected products were inadvertently packaged with an incorrect screw component. 12 units
2017-05-30 Class II Process control The incorrect Loctite adhesive was used to assemble the impactor heads. 36 units 2021-12-10
2017-05-30 Class II Process control The incorrect Loctite adhesive was used to assemble the impactor heads. 46 units 2021-12-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
22 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
33 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
15 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
6 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
6 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
34 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
33 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
2 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
1 unit 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
24 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
1 unit 2017-04-10

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer