Itotal Identity Posterior Stabilized Knee Replacement System

The iTotal Identity Posterior Stabilized knee system includes a patient-specific titanium alloy tibial tray that supports polyethylene bearing inserts. It forms the lower part of a total…

Registry build 21.09.26

The iTotal Identity Posterior Stabilized knee system includes a patient-specific titanium alloy tibial tray that supports polyethylene bearing inserts. It forms the lower part of a total knee replacement, paired with a cobalt-chromium-molybdenum femoral component and, when used, a polyethylene patellar component.

Patient CT or MR images are used to design the implant geometry for the individual’s anatomy. The system replaces the joint surfaces across the knee rather than treating only one or two compartments.

Listed Item

Itotal Identity PS Replacement Tibial Tray (Titanium, Cemented)

Surgical Planning and Placement

Patient-specific, single-use manual instruments help position the components and guide bone cuts during surgery. Reusable instruments are provided separately. The implants are intended for cemented fixation, including procedures where damaged knee surfaces cause pain and disability and appropriate anatomical landmarks can be identified on the patient’s scans.

21manufacturers in China registered for this device type
88catalogue numbers in this listing
40510(k) clearances naming this product code
19recalls on this code

Who Else Makes It

Concentrated in Jiangsu (10), Shanghai (4), Beijing (3). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JWH
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Changzhou Wastonortho Medical Appliance Co., Ltd. Changzhou Jiangsu Contract manufacturer 5

Showing 12 of 21. All 21 manufacturers in China registered for Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

Record

Regulatory record for iTotal Identity Posterior Stabilized Knee Replacement System
Listed by ConforMIS, Inc., United States
FDA product code JWH
Device type Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3560
Establishment Remanufacturer, Reprocessor, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K201023
Record published 2020-07-13
Record revised 2020-07-15 (version 2)

Specifications

Specifications
MRI safety MR Conditional
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries expiry date, serial number
Sizes Height 6 to 22 mm

Catalogue Numbers

Catalogue numbers for iTotal Identity Posterior Stabilized Knee Replacement System
Catalogue number Size Status
TPS010100001 Height 10 mm In distribution
RPS020110003 Height 11 mm In distribution
RPS020140013 Height 14 mm In distribution
RPS020190003 Height 19 mm In distribution
RPS020170003 Height 17 mm In distribution
RPS010120013 Height 12 mm In distribution
RPS010190003 Height 19 mm In distribution
RPS301111301 In distribution
RPS010090003 Height 9 mm In distribution
RPS020210013 Height 21 mm In distribution
TPS010060001 Height 6 mm In distribution
RPS010130003 Height 13 mm In distribution
RPS020120013 Height 12 mm In distribution
RPS020140003 Height 14 mm In distribution
RPS020080003 Height 8 mm In distribution
RPS020190013 Height 19 mm In distribution
RPS010200003 Height 20 mm In distribution
RPS020130003 Height 13 mm In distribution
RPS020200013 Height 20 mm In distribution
RPS020200003 Height 20 mm In distribution
RPS010060003 Height 6 mm In distribution
TPS020080001 Height 8 mm In distribution
RPS010070013 Height 7 mm In distribution
TPS020060001 Height 6 mm In distribution
RPS020180013 Height 18 mm In distribution
RPS010100013 Height 10 mm In distribution
RPS020150013 Height 15 mm In distribution
RPS010090013 Height 9 mm In distribution
RPS020070003 Height 7 mm In distribution
RPS010160013 Height 16 mm In distribution
RPS020090003 Height 9 mm In distribution
TPS020140001 Height 14 mm In distribution
RPS010220013 Height 22 mm In distribution
RPS020100003 Height 10 mm In distribution
TPS010090001 Height 9 mm In distribution
RPS010130013 Height 13 mm In distribution
RPS010100003 Height 10 mm In distribution
RPS010220003 Height 22 mm In distribution
TPS020130001 Height 13 mm In distribution
TPS010080001 Height 8 mm In distribution
TPS101111201 In distribution
TPS020090001 Height 9 mm In distribution
RPS020130013 Height 13 mm In distribution
TPS301111301 In distribution
RPS020120003 Height 12 mm In distribution
RPS020210003 Height 21 mm In distribution
RPS020160003 Height 16 mm In distribution
RPS010110003 Height 11 mm In distribution
RPS020110013 Height 11 mm In distribution
TPS010070001 Height 7 mm In distribution
TPS000D00101 In distribution
TPS020110001 Height 11 mm In distribution
RPS020220003 Height 22 mm In distribution
TPS010130001 Height 13 mm In distribution
RPS020090013 Height 9 mm In distribution
RPS020160013 Height 16 mm In distribution
TPS020100001 Height 10 mm In distribution
RPS010070003 Height 7 mm In distribution
RPS010080013 Height 8 mm In distribution
RPS010150003 Height 15 mm In distribution
RPS010210003 Height 21 mm In distribution
RPS010120003 Height 12 mm In distribution
RPS020100013 Height 10 mm In distribution
RPS020180003 Height 18 mm In distribution
RPS010210013 Height 21 mm In distribution
RPS020060003 Height 6 mm In distribution
TPS020120001 Height 12 mm In distribution
TPS010120001 Height 12 mm In distribution
TPS010110001 Height 11 mm In distribution
RPS010170003 Height 17 mm In distribution
RPS010180013 Height 18 mm In distribution
RPS010140013 Height 14 mm In distribution
TPS020070001 Height 7 mm In distribution
RPS020080013 Height 8 mm In distribution
RPS010080003 Height 8 mm In distribution
RPS010200013 Height 20 mm In distribution
RPS010180003 Height 18 mm In distribution
RPS010110013 Height 11 mm In distribution
RPS020060013 Height 6 mm In distribution
RPS010140003 Height 14 mm In distribution
RPS010190013 Height 19 mm In distribution
RPS010170013 Height 17 mm In distribution
RPS010150013 Height 15 mm In distribution
RPS010160003 Height 16 mm In distribution
RPS020150003 Height 15 mm In distribution
RPS010060013 Height 6 mm In distribution
RPS020070013 Height 7 mm In distribution
RPS020220013 Height 22 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Prophecy® Microport Orthopedics Inc. 4,423
Exult Knee Replacement System Corentec Co., Ltd. 1,770
Freedom Maxx Orthopedics Inc. 1,693
Legion Smith & Nephew, Inc. 1,534
MyKnee Medacta International SA 1,466
Journey Smith & Nephew, Inc. 1,339
Persona® Zimmer, Inc. 1,254
DJO Surgical Encore Medical, L.P. 1,131
U2 Total Knee System United Orthopedic Corp. 1,078
CKS Plus Shalby Advanced Technologies, Inc. 1,024
Lospa Modular Knee System Corentec Co., Ltd. 1,020
Natural-Knee® Zimmer, Inc. 980

Showing 12 of 1,175. All products under Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K230846 2023-07-17
K231233 2023-05-26
K230844 2023-04-27
K221404 2022-07-26
K221059 2022-05-10
K213389 2021-11-10
K212411 2021-09-23
K210809 2021-05-12
K210191 2021-05-06
K210252 2021-02-17
K203447 2020-12-22
K201023 2020-06-16
K193105 2020-03-13
K190562 2019-08-08
K180906 2018-05-16
K161668 2016-07-15
K161366 2016-06-14
K153721 2016-03-25
K160025 2016-03-07
K153217 2016-01-07
K152704 2015-10-21
K142404 2014-12-11
K142161 2014-11-14
K140833 2014-06-30
K140423 2014-05-27
K133560 2014-03-28
K133256 2014-01-09
K131467 2013-07-18
K131019 2013-05-24
K122870 2013-01-14
K122991 2012-12-20
K122033 2012-09-27
K120316 2012-04-19
K113378 2012-02-15
K120068 2012-02-03
K112780 2011-12-15
K103117 2011-01-07
K094050 2010-09-16
K080936 2008-05-12
K052687 2006-08-31

Recalls Naming This Product

1 recall names this product by its own identifier, the UDI on its label.

Recalls naming the identifiers of iTotal Identity Posterior Stabilized Knee Replacement System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
ConforMIS, Inc. UDI-DI 2022-02-22 Class II Nonconforming Material/Component Incorrect tibial base plate implant packaged in kit 1 unit

Recalls

18 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2024-03-11 Class II Process design Size 5 Tibial Tray from Lot 508287 was packaged in a Size 4 box from Lot 540287. It was confirmed that Lot 540287 and Lot 508287 were swapped between the pouching and final pack. 3 units
2020-07-20 Class II Packaging process control Outer box labels for kit 0469247 correct, however the boxes contained the implants and jigs for 0468920 1 kit 2021-06-21
2020-02-03 Class II Mixed-up of materials/components A limited number of tibial trays were labeled with an incorrect serial number and were delivered to the wrong customer accounts. 4 2020-12-02
2020-02-03 Class II Mixed-up of materials/components A limited number of tibial trays were labeled with an incorrect serial number and were delivered to the wrong customer accounts. 2 2020-12-02
2019-10-25 Class II Under Investigation by firm Medial and lateral polyethylene inserts did not securely fit into the cobalt chrome tray implant. 1 unit 2020-05-20
2019-01-04 Class II Employee error The labeling of the boxes and sterile pouches did not match the contents. 2 2020-06-29
2018-12-03 Class II Labeling mix-ups The kits were prepared with incorrect patient ID labels and may contain incorrect components. 2 2020-06-26
2017-07-24 Class II Employee error Implant kit mislabeled 2 units 2019-02-01
2016-10-31 Class II Software Design Change iView report displayed femoral cut measurements in the incorrect unit of measure (inches vs. mm). 1 unit 2017-01-11
2016-10-18 Class II Labeling Change Control Mislabeled: incorrect serial number on the F4 A/P cut guide iJig. 2 units 2016-12-07
2016-01-28 Class II Packaging process control Incorrect femoral component distributed 1 unit 2016-03-09
2015-08-31 Class II Process design May contain small amounts of ethylene glycol residue 313 units 2016-03-02
2015-08-31 Class II Process design May contain small amounts of ethylene glycol residue 3 units 2016-03-02
2015-08-31 Class II Process design May contain small amounts of ethylene glycol residue 110 units 2016-03-02
2015-08-31 Class II Process design May contain small amounts of ethylene glycol residue 68 units 2016-03-02
2015-08-31 Class II Process design May contain small amounts of ethylene glycol residue 348 units 2016-03-02
2014-11-19 Class II Labeling mix-ups Incorrect serial number of tibial inserts packaged in tray may result in inserts not fitting 1 unit 2015-10-08
2012-07-17 Class II Device Design Addendum Labeling iTotal CR Surgical Technique with Detailed Instructions of Total CR Poly Insertion Technique 1427 units 2013-02-27

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer