Itotal® PS Tibial Tray Impactor Tip
iTotal® PS Tibial Tray Impactor Tip Reusable Instrument
Who Else Makes It
Concentrated in Jiangsu (10), Shanghai (4), Beijing (3). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Guangzhou Aquila Precise Tools Limited | Guangzhou | Guangdong | Contract manufacturer | 28 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 10 |
| b-ONE Medical (Beijing) Co., Ltd. | Beijing | Beijing | Contract manufacturer | 7 |
| Changzhou Wastonortho Medical Appliance Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 5 |
Showing 12 of 21. All 21 manufacturers in China registered for Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
Record
| Listed by | ConforMIS, Inc., United States |
|---|---|
| FDA product code | JWH |
| Device type | Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3560 |
| Establishment | Remanufacturer, Reprocessor, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K160025 |
| Record published | 2016-10-24 |
| Record revised | 2026-02-09 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Prescription | Prescription only |
| Label carries | lot or batch number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 1080-542 | one size | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Prophecy® | Microport Orthopedics Inc. | 4,423 |
| Exult Knee Replacement System | Corentec Co., Ltd. | 1,770 |
| Freedom | Maxx Orthopedics Inc. | 1,693 |
| Legion | Smith & Nephew, Inc. | 1,534 |
| MyKnee | Medacta International SA | 1,466 |
| Journey | Smith & Nephew, Inc. | 1,339 |
| Persona® | Zimmer, Inc. | 1,254 |
| DJO Surgical | Encore Medical, L.P. | 1,131 |
| U2 Total Knee System | United Orthopedic Corp. | 1,078 |
| CKS Plus | Shalby Advanced Technologies, Inc. | 1,024 |
| Lospa Modular Knee System | Corentec Co., Ltd. | 1,020 |
| Natural-Knee® | Zimmer, Inc. | 980 |
Showing 12 of 1,175. All products under Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K230846 | 2023-07-17 |
| K231233 | 2023-05-26 |
| K230844 | 2023-04-27 |
| K221404 | 2022-07-26 |
| K221059 | 2022-05-10 |
| K213389 | 2021-11-10 |
| K212411 | 2021-09-23 |
| K210809 | 2021-05-12 |
| K210191 | 2021-05-06 |
| K210252 | 2021-02-17 |
| K203447 | 2020-12-22 |
| K201023 | 2020-06-16 |
| K193105 | 2020-03-13 |
| K190562 | 2019-08-08 |
| K180906 | 2018-05-16 |
| K161668 | 2016-07-15 |
| K161366 | 2016-06-14 |
| K153721 | 2016-03-25 |
| K160025 | 2016-03-07 |
| K153217 | 2016-01-07 |
| K152704 | 2015-10-21 |
| K142404 | 2014-12-11 |
| K142161 | 2014-11-14 |
| K140833 | 2014-06-30 |
| K140423 | 2014-05-27 |
| K133560 | 2014-03-28 |
| K133256 | 2014-01-09 |
| K131467 | 2013-07-18 |
| K131019 | 2013-05-24 |
| K122870 | 2013-01-14 |
| K122991 | 2012-12-20 |
| K122033 | 2012-09-27 |
| K120316 | 2012-04-19 |
| K113378 | 2012-02-15 |
| K120068 | 2012-02-03 |
| K112780 | 2011-12-15 |
| K103117 | 2011-01-07 |
| K094050 | 2010-09-16 |
| K080936 | 2008-05-12 |
| K052687 | 2006-08-31 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| ConforMIS, Inc. | 510(k) number | 2016-10-18 | Class II | Labeling Change Control | Mislabeled: incorrect serial number on the F4 A/P cut guide iJig. | 2 units | 2016-12-07 |
Recalls
18 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2024-03-11 | Class II | Process design | Size 5 Tibial Tray from Lot 508287 was packaged in a Size 4 box from Lot 540287. It was confirmed that Lot 540287 and Lot 508287 were swapped between the pouching and final pack. | 3 units | |
| 2022-02-22 | Class II | Nonconforming Material/Component | Incorrect tibial base plate implant packaged in kit | 1 unit | |
| 2020-07-20 | Class II | Packaging process control | Outer box labels for kit 0469247 correct, however the boxes contained the implants and jigs for 0468920 | 1 kit | 2021-06-21 |
| 2020-02-03 | Class II | Mixed-up of materials/components | A limited number of tibial trays were labeled with an incorrect serial number and were delivered to the wrong customer accounts. | 4 | 2020-12-02 |
| 2020-02-03 | Class II | Mixed-up of materials/components | A limited number of tibial trays were labeled with an incorrect serial number and were delivered to the wrong customer accounts. | 2 | 2020-12-02 |
| 2019-10-25 | Class II | Under Investigation by firm | Medial and lateral polyethylene inserts did not securely fit into the cobalt chrome tray implant. | 1 unit | 2020-05-20 |
| 2019-01-04 | Class II | Employee error | The labeling of the boxes and sterile pouches did not match the contents. | 2 | 2020-06-29 |
| 2018-12-03 | Class II | Labeling mix-ups | The kits were prepared with incorrect patient ID labels and may contain incorrect components. | 2 | 2020-06-26 |
| 2017-07-24 | Class II | Employee error | Implant kit mislabeled | 2 units | 2019-02-01 |
| 2016-10-31 | Class II | Software Design Change | iView report displayed femoral cut measurements in the incorrect unit of measure (inches vs. mm). | 1 unit | 2017-01-11 |
| 2016-01-28 | Class II | Packaging process control | Incorrect femoral component distributed | 1 unit | 2016-03-09 |
| 2015-08-31 | Class II | Process design | May contain small amounts of ethylene glycol residue | 313 units | 2016-03-02 |
| 2015-08-31 | Class II | Process design | May contain small amounts of ethylene glycol residue | 3 units | 2016-03-02 |
| 2015-08-31 | Class II | Process design | May contain small amounts of ethylene glycol residue | 110 units | 2016-03-02 |
| 2015-08-31 | Class II | Process design | May contain small amounts of ethylene glycol residue | 68 units | 2016-03-02 |
| 2015-08-31 | Class II | Process design | May contain small amounts of ethylene glycol residue | 348 units | 2016-03-02 |
| 2014-11-19 | Class II | Labeling mix-ups | Incorrect serial number of tibial inserts packaged in tray may result in inserts not fitting | 1 unit | 2015-10-08 |
| 2012-07-17 | Class II | Device Design | Addendum Labeling iTotal CR Surgical Technique with Detailed Instructions of Total CR Poly Insertion Technique | 1427 units | 2013-02-27 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.