Journey II XR

Journey II XR includes separate medial and lateral cross-linked polyethylene articular inserts and left- or right-sided titanium-alloy tibial bases. The inserts form the bearing surfaces…

Registry build 21.09.26

Journey II XR includes separate medial and lateral cross-linked polyethylene articular inserts and left- or right-sided titanium-alloy tibial bases. The inserts form the bearing surfaces that work with the compatible femoral component.

The inserts lock into the tibial baseplate. The system uses existing Journey II CR femoral components and compatible patellar components, with instruments specific to the XR reconstruction.

Listed Item

Journey II XR Articular Insert Xlpe Lateral Size 3-4 Right 10MM -2 Degree

Component Assembly

The tibial baseplates use Ti-6Al-4V titanium alloy. Medial and lateral insert options are selected for the knee and side being reconstructed. The knee components are single-use devices intended for cemented fixation.

21manufacturers in China registered for this device type
514catalogue numbers in this listing
49510(k) clearances naming this product code
40recalls on this code

Who Else Makes It

Concentrated in Jiangsu (10), Shanghai (4), Beijing (3). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JWH
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Changzhou Wastonortho Medical Appliance Co., Ltd. Changzhou Jiangsu Contract manufacturer 5

Showing 12 of 21. All 21 manufacturers in China registered for Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

Record

Regulatory record for Journey II XR
Listed by Smith & Nephew, Inc., United States
FDA product code JWH
Device type Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3560
Establishment Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K152726
Record published 2015-11-25
Record revised 2023-09-07 (version 8)

Specifications

Specifications
MRI safety MR Conditional
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date
Storage Special storage condition: : –

Catalogue Numbers

Catalogue numbers for Journey II XR
Catalogue number Size Per pack Status
74023975 In distribution
74014472 In distribution
74023710 In distribution
74033705 In distribution
74013882 In distribution
74023833 In distribution
74023962 In distribution
74013969 In distribution
74013868 In distribution
74013956 In distribution
74023774 In distribution
74013968 In distribution
74023992 In distribution
74033586 In distribution
74013905 In distribution
74013816 In distribution
74033719 In distribution
74023955 In distribution
74013933 In distribution
74013894 In distribution
74013944 In distribution
74024035 In distribution
74024037 In distribution
74013843 In distribution
74023771 In distribution
74033794 In distribution
74033576 In distribution
74023744 In distribution
74022296 In distribution
74013845 In distribution
74013989 In distribution
74033791 In distribution
74013867 In distribution
74013953 In distribution
74033793 In distribution
74013885 In distribution
74023842 In distribution
74022297 In distribution
74024031 In distribution
74024029 In distribution
74033782 In distribution
74033581 In distribution
74033740 In distribution
74022295 In distribution
74023743 In distribution
74023813 In distribution
74033588 In distribution
74033718 In distribution
74013903 In distribution
74024017 In distribution
74033788 In distribution
74033771 In distribution
74023871 In distribution
74033593 In distribution
E0015507-3 In distribution
74023951 In distribution
74033756 In distribution
74013984 In distribution
74013902 In distribution
74023974 In distribution
74013802 In distribution
74013822 In distribution
74023983 In distribution
74023711 In distribution
74013841 In distribution
74013909 In distribution
74013878 In distribution
74013946 In distribution
74013839 In distribution
74014531 3 In distribution
74023991 In distribution
74023966 In distribution
74033715 In distribution
74023965 In distribution
74023882 In distribution
74023730 In distribution
74022291 Size: 1 right In distribution
74013852 In distribution
74013935 In distribution
74024028 In distribution
74013965 In distribution
74033528 In distribution
74023994 In distribution
E0015507-1 In distribution
74013828 In distribution
74033587 In distribution
74033739 In distribution
74023989 In distribution
74023870 In distribution
74013836 In distribution
74013851 In distribution
74023832 In distribution
74033572 In distribution
74033789 In distribution
74013861 In distribution
74013972 In distribution
74013871 In distribution
74023782 In distribution
74033731 In distribution
74033573 In distribution
74014476 In distribution
74013826 In distribution
74023831 In distribution
74023853 In distribution
74023773 In distribution
74023973 In distribution
74013937 In distribution
74024015 In distribution
74013833 In distribution
74013978 In distribution
74023761 In distribution
74023732 In distribution
74023733 In distribution
74023953 In distribution
74022202 In distribution
74013952 In distribution
74033708 In distribution
74033778 In distribution
74023770 In distribution
74033799 In distribution
74013824 In distribution
74013847 In distribution
74033591 In distribution
74033722 In distribution
74013977 In distribution
74023723 In distribution
74023734 In distribution
74023861 In distribution
74013811 In distribution
74013906 In distribution
74013890 In distribution
74014481 In distribution
74013895 In distribution
74033575 In distribution
74033795 In distribution
74033568 In distribution
74013987 In distribution
74023995 In distribution
74013904 In distribution
74014495 In distribution
74023963 In distribution
74013862 In distribution
74033735 In distribution
74023977 In distribution
74014526 In distribution
74024004 In distribution
74033742 In distribution
E0015507-2 In distribution
74022205 In distribution
74013818 In distribution
74013897 In distribution
74023830 In distribution
74023993 In distribution
74013819 In distribution
74033759 In distribution
74014527 In distribution
74023780 In distribution
74023812 In distribution
74013884 In distribution
74033598 In distribution
74013883 In distribution
74013879 In distribution
74033713 In distribution
74023952 In distribution
74033569 In distribution
74013971 In distribution
74023850 In distribution
74024009 In distribution
74023852 In distribution
74033744 In distribution
74013886 In distribution
74023863 In distribution
74023987 In distribution
74022294 In distribution
74013907 In distribution
74033571 In distribution
74033704 In distribution
74013896 In distribution
74033783 In distribution
74013981 In distribution
74033597 In distribution
74023881 In distribution
74024014 In distribution
74033595 In distribution
74033711 In distribution
74013849 In distribution
74023754 In distribution
74023967 In distribution
74023988 In distribution
74013863 In distribution
74013929 In distribution
74033753 In distribution
74013958 In distribution
74033594 In distribution
74033772 In distribution
74022207 In distribution
74033701 In distribution
74013957 In distribution
74013814 In distribution
74013838 In distribution
74023968 In distribution
74033734 In distribution
74013924 In distribution
74033755 In distribution
74013872 In distribution
74013856 In distribution
74013975 In distribution
74024039 In distribution
74013998 In distribution
74013967 In distribution
74013855 In distribution
74023957 In distribution
74013825 In distribution
74014498 In distribution
74013976 In distribution
74014535 3 In distribution
74013809 In distribution
74023982 In distribution
74013827 In distribution
74013834 In distribution
74013928 In distribution
74013864 In distribution
74023753 In distribution
74033725 In distribution
74014485 In distribution
74014471 In distribution
74033579 In distribution
74013921 In distribution
74033577 In distribution
74033736 In distribution
74033748 In distribution
74013923 In distribution
74013812 In distribution
74013982 In distribution
74023874 In distribution
74013985 In distribution
74013893 In distribution
74023961 In distribution
74033733 In distribution
74033707 In distribution
74022292 Size: 2 right In distribution
74023762 In distribution
74033777 In distribution
74023854 In distribution
74033758 In distribution
74023823 In distribution
74013959 In distribution
74024021 In distribution
74013823 In distribution
74033724 In distribution

Showing 250 of 300 catalogue numbers.

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Prophecy® Microport Orthopedics Inc. 4,423
Exult Knee Replacement System Corentec Co., Ltd. 1,770
Freedom Maxx Orthopedics Inc. 1,693
Legion Smith & Nephew, Inc. 1,534
MyKnee Medacta International SA 1,466
Journey Smith & Nephew, Inc. 1,339
Persona® Zimmer, Inc. 1,254
DJO Surgical Encore Medical, L.P. 1,131
U2 Total Knee System United Orthopedic Corp. 1,078
CKS Plus Shalby Advanced Technologies, Inc. 1,024
Lospa Modular Knee System Corentec Co., Ltd. 1,020
Natural-Knee® Zimmer, Inc. 980

Showing 12 of 1,175. All products under Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K250677 2025-04-02
K230653 2023-05-04
K230555 2023-03-30
K221939 2022-07-26
K220896 2022-04-26
K211671 2021-08-17
K200227 2020-06-04
K200826 2020-04-24
K200407 2020-03-13
K183010 2018-11-28
K180334 2018-03-05
K172336 2018-01-10
K173331 2017-11-16
K170282 2017-05-22
K170648 2017-05-11
K162775 2017-01-13
K150241 2015-10-27
K152726 2015-10-21
K143226 2015-02-12
K142807 2014-12-22
K141471 2014-11-14
K141585 2014-08-21
K140555 2014-05-29
K130708 2013-12-11
K123159 2013-05-03
K121443 2012-08-13
K120698 2012-05-18
K113482 2012-02-27
K112941 2011-12-20
K111711 2011-09-16
K110837 2011-04-22
K101499 2010-08-26
K093746 2010-04-14
K091014 2009-09-29
K082358 2008-11-25
K072531 2007-12-06
K072858 2007-11-20
K071071 2007-09-19
K060742 2006-05-03
K051229 2005-07-20
K042515 2005-03-14
K041825 2005-03-11
K043440 2005-02-18
K041106 2004-07-01
K032295 2003-08-21
K030301 2003-02-25
K022010 2002-08-19
K012778 2002-03-15
K002740 2000-11-30

Recalls Naming This Product

5 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Journey II XR
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Smith & Nephew, Inc. 510(k) number 2023-08-31 Class II Labeling Change Control The firm conducting a recall due to a complaint received indicating that a package contained a LEGION NARROW PS OXIN SZ 4N LT implant instead of a LEGION NARROW PSvOXIN SZ 5N LT as described on the product label. 8 units
Smith & Nephew, Inc. 510(k) number 2018-12-10 Class II Device Design Higher than anticipated occurrence of bone fracture during the use of the XR Tibia Posterior Punch 65 units 2020-11-03
Smith & Nephew, Inc. 510(k) number 2018-12-10 Class II Device Design Higher than anticipated occurrence of bone fracture during the use of the XR Tibia Posterior Punch 65 units 2020-11-03
Smith & Nephew, Inc. 510(k) number 2018-12-10 Class II Device Design Higher than anticipated occurrence of bone fracture during the use of the XR Tibia Posterior Punch 65 units 2020-11-03
Smith & Nephew, Inc. 510(k) number 2018-12-10 Class II Device Design Higher than anticipated occurrence of bone fracture during the use of the XR Tibia Posterior Punch 46 units 2020-11-03

Recalls

35 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2024-10-02 Class II Packaging change control Complaint received indicating that a package contained a LEGION NARROW PS OXIN SZ 5N RIGHT implant instead of a GENESIS II POSTERIOR STABILIZED FEMORAL SIZE 5 LEFT as described on the product label. 5 units
2024-10-02 Class II Packaging change control Complaint received indicating that a package contained a LEGION NARROW PS OXIN SZ 5N RIGHT implant instead of a GENESIS II POSTERIOR STABILIZED FEMORAL SIZE 5 LEFT as described on the product label. 8 units
2024-10-02 Class II Packaging change control Complaint received indicating that a package contained a LGN OX CONSTRAINED FEM 3 LT implant instead of a LGN OX CONSTRAINED FEM 4 LT as described on the product label. 2 units
2024-10-02 Class II Packaging change control Complaint received indicating that a package contained a LGN OX CONSTRAINED FEM 3 LT implant instead of a LGN OX CONSTRAINED FEM 4 LT as described on the product label. 3 units
2023-09-27 Class II Component change control The JRNY II BCS XLPE ART ISRT SZ 5-6 LT 10MM was laser etched, labeled and packaged as a JRNY II BCS CNSTRD ART ISRT 5-6 LT 10MM. And also, a JRNY II BCS CNSTRD ART ISRT 5-6 LT 10MM was laser etched, labeled and packaged as a JRNY II BCS XL 29 units
2023-09-27 Class II Component change control The JRNY II BCS XLPE ART ISRT SZ 5-6 LT 10MM was laser etched, labeled and packaged as a JRNY II BCS CNSTRD ART ISRT 5-6 LT 10MM. And also, a JRNY II BCS CNSTRD ART ISRT 5-6 LT 10MM was laser etched, labeled and packaged as a JRNY II BCS XL 28 units
2022-06-27 Class II Process control The product was mispackaged (swapped). The devices within the inner tray matches the inner tray but does not match the outer box label and the chart sticks. 31 devices 2026-03-25
2022-04-19 Class II Nonconforming Material/Component It was reported that a JOURNEY II BCS Femoral OXIN LT SZ5 was in a box labelled as a LEGION NARROW PS OXIN SZ 6N RT. 16 units 2024-08-16
2021-05-19 Class II Nonconforming Material/Component The device components experienced a manufacturing process error that resulted in surface damage from product handling. 5 units 2023-04-14
2020-09-21 Class II Nonconforming Material/Component The anterior locking detail does not meet its design specifications. 47 devices 2026-05-22
2020-07-16 Class II Nonconforming Material/Component Due to an inconsistency in the raw material process, specific lots may contain units with internal non-homogenous material defects. 1,845 units
2019-12-19 Class II Process control LEGION PS High Flex XLPE Articular Insert was packaged with an incorrect part 29 units 2024-09-04
2018-06-13 Class II Other The data in the National Joint Registry of England, Wales and Northern Ireland (NJREWNI) and Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) indicate that the first generation JOURNEY BCS Knee System has a r 10,792 units
2018-06-13 Class II Other The data in the National Joint Registry of England, Wales and Northern Ireland (NJREWNI) and Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) indicate that the first generation JOURNEY BCS Knee System has a r 42,050 units
2018-06-13 Class II Other The data in the National Joint Registry of England, Wales and Northern Ireland (NJREWNI) and Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) indicate that the first generation JOURNEY BCS Knee System has a r 64642
2018-03-30 Class II Packaging process control The affected products were inadvertently packaged with the inner packaging pouch being sealed together with the outer pouch. 2019-08-21
2018-03-30 Class II Packaging process control The affected products were inadvertently packaged with the inner packaging pouch being sealed together with the outer pouch. 47 units 2019-08-21
2018-03-30 Class II Packaging process control The affected products were inadvertently packaged with the inner packaging pouch being sealed together with the outer pouch. 72 units 2019-08-21
2018-03-30 Class II Packaging process control The affected products were inadvertently packaged with the inner packaging pouch being sealed together with the outer pouch. 16 units 2019-08-21
2018-01-15 Class II Process control The affected products were inadvertently packaged with an incorrect screw component. 12 units
2017-09-14 Class II Mixed-up of materials/components The Legion Screw-on Wedge Size 4 contained 5MM screws instead of the required 10MM screw. 10 units 2020-08-21
2017-08-01 Class II Employee error Two lots of Genesis II Non Porous C/R Femoral Size 6 right packaged were distributed containing Genesis II C/R Femoral Size 4 left. 27 units 2019-02-19
2017-05-30 Class II Process control The incorrect Loctite adhesive was used to assemble the impactor heads. 36 units 2021-12-10
2017-05-30 Class II Process control The incorrect Loctite adhesive was used to assemble the impactor heads. 46 units 2021-12-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
22 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
33 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
15 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
6 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
6 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
34 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
33 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
2 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
1 unit 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
24 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
1 unit 2017-04-10

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer