Legion Revision

Tibial Cutting Block - Right

Registry build 21.09.26
21manufacturers in China registered for this device type
5catalogue numbers in this listing
49510(k) clearances naming this product code
40recalls on this code

Who Else Makes It

Concentrated in Jiangsu (10), Shanghai (4), Beijing (3). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JWH
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Changzhou Wastonortho Medical Appliance Co., Ltd. Changzhou Jiangsu Contract manufacturer 5

Showing 12 of 21. All 21 manufacturers in China registered for Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

Record

Regulatory record for Legion Revision
Listed by Smith & Nephew, Inc., United States
FDA product code JWH
Device type Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3560
Establishment Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K121393
Record published 2016-10-20
Record revised 2023-09-07 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Legion Revision
Catalogue number Size Status
E0015235-3 In distribution
E0015235-1 In distribution
E0015368-1 In distribution
E0015336-1 In distribution
E0015235-2 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Prophecy® Microport Orthopedics Inc. 4,423
Exult Knee Replacement System Corentec Co., Ltd. 1,770
Freedom Maxx Orthopedics Inc. 1,693
Legion Smith & Nephew, Inc. 1,534
MyKnee Medacta International SA 1,466
Journey Smith & Nephew, Inc. 1,339
Persona® Zimmer, Inc. 1,254
DJO Surgical Encore Medical, L.P. 1,131
U2 Total Knee System United Orthopedic Corp. 1,078
CKS Plus Shalby Advanced Technologies, Inc. 1,024
Lospa Modular Knee System Corentec Co., Ltd. 1,020
Natural-Knee® Zimmer, Inc. 980

Showing 12 of 1,175. All products under Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K250677 2025-04-02
K230653 2023-05-04
K230555 2023-03-30
K221939 2022-07-26
K220896 2022-04-26
K211671 2021-08-17
K200227 2020-06-04
K200826 2020-04-24
K200407 2020-03-13
K183010 2018-11-28
K180334 2018-03-05
K172336 2018-01-10
K173331 2017-11-16
K170282 2017-05-22
K170648 2017-05-11
K162775 2017-01-13
K150241 2015-10-27
K152726 2015-10-21
K143226 2015-02-12
K142807 2014-12-22
K141471 2014-11-14
K141585 2014-08-21
K140555 2014-05-29
K130708 2013-12-11
K123159 2013-05-03
K121443 2012-08-13
K120698 2012-05-18
K113482 2012-02-27
K112941 2011-12-20
K111711 2011-09-16
K110837 2011-04-22
K101499 2010-08-26
K093746 2010-04-14
K091014 2009-09-29
K082358 2008-11-25
K072531 2007-12-06
K072858 2007-11-20
K071071 2007-09-19
K060742 2006-05-03
K051229 2005-07-20
K042515 2005-03-14
K041825 2005-03-11
K043440 2005-02-18
K041106 2004-07-01
K032295 2003-08-21
K030301 2003-02-25
K022010 2002-08-19
K012778 2002-03-15
K002740 2000-11-30

Recalls

40 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2024-10-02 Class II Packaging change control Complaint received indicating that a package contained a LEGION NARROW PS OXIN SZ 5N RIGHT implant instead of a GENESIS II POSTERIOR STABILIZED FEMORAL SIZE 5 LEFT as described on the product label. 5 units
2024-10-02 Class II Packaging change control Complaint received indicating that a package contained a LEGION NARROW PS OXIN SZ 5N RIGHT implant instead of a GENESIS II POSTERIOR STABILIZED FEMORAL SIZE 5 LEFT as described on the product label. 8 units
2024-10-02 Class II Packaging change control Complaint received indicating that a package contained a LGN OX CONSTRAINED FEM 3 LT implant instead of a LGN OX CONSTRAINED FEM 4 LT as described on the product label. 2 units
2024-10-02 Class II Packaging change control Complaint received indicating that a package contained a LGN OX CONSTRAINED FEM 3 LT implant instead of a LGN OX CONSTRAINED FEM 4 LT as described on the product label. 3 units
2023-09-27 Class II Component change control The JRNY II BCS XLPE ART ISRT SZ 5-6 LT 10MM was laser etched, labeled and packaged as a JRNY II BCS CNSTRD ART ISRT 5-6 LT 10MM. And also, a JRNY II BCS CNSTRD ART ISRT 5-6 LT 10MM was laser etched, labeled and packaged as a JRNY II BCS XL 29 units
2023-09-27 Class II Component change control The JRNY II BCS XLPE ART ISRT SZ 5-6 LT 10MM was laser etched, labeled and packaged as a JRNY II BCS CNSTRD ART ISRT 5-6 LT 10MM. And also, a JRNY II BCS CNSTRD ART ISRT 5-6 LT 10MM was laser etched, labeled and packaged as a JRNY II BCS XL 28 units
2023-08-31 Class II Labeling Change Control The firm conducting a recall due to a complaint received indicating that a package contained a LEGION NARROW PS OXIN SZ 4N LT implant instead of a LEGION NARROW PSvOXIN SZ 5N LT as described on the product label. 8 units
2022-06-27 Class II Process control The product was mispackaged (swapped). The devices within the inner tray matches the inner tray but does not match the outer box label and the chart sticks. 31 devices 2026-03-25
2022-04-19 Class II Nonconforming Material/Component It was reported that a JOURNEY II BCS Femoral OXIN LT SZ5 was in a box labelled as a LEGION NARROW PS OXIN SZ 6N RT. 16 units 2024-08-16
2021-05-19 Class II Nonconforming Material/Component The device components experienced a manufacturing process error that resulted in surface damage from product handling. 5 units 2023-04-14
2020-09-21 Class II Nonconforming Material/Component The anterior locking detail does not meet its design specifications. 47 devices 2026-05-22
2020-07-16 Class II Nonconforming Material/Component Due to an inconsistency in the raw material process, specific lots may contain units with internal non-homogenous material defects. 1,845 units
2019-12-19 Class II Process control LEGION PS High Flex XLPE Articular Insert was packaged with an incorrect part 29 units 2024-09-04
2018-12-10 Class II Device Design Higher than anticipated occurrence of bone fracture during the use of the XR Tibia Posterior Punch 46 units 2020-11-03
2018-12-10 Class II Device Design Higher than anticipated occurrence of bone fracture during the use of the XR Tibia Posterior Punch 65 units 2020-11-03
2018-12-10 Class II Device Design Higher than anticipated occurrence of bone fracture during the use of the XR Tibia Posterior Punch 65 units 2020-11-03
2018-12-10 Class II Device Design Higher than anticipated occurrence of bone fracture during the use of the XR Tibia Posterior Punch 65 units 2020-11-03
2018-06-13 Class II Other The data in the National Joint Registry of England, Wales and Northern Ireland (NJREWNI) and Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) indicate that the first generation JOURNEY BCS Knee System has a r 10,792 units
2018-06-13 Class II Other The data in the National Joint Registry of England, Wales and Northern Ireland (NJREWNI) and Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) indicate that the first generation JOURNEY BCS Knee System has a r 42,050 units
2018-06-13 Class II Other The data in the National Joint Registry of England, Wales and Northern Ireland (NJREWNI) and Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) indicate that the first generation JOURNEY BCS Knee System has a r 64642
2018-03-30 Class II Packaging process control The affected products were inadvertently packaged with the inner packaging pouch being sealed together with the outer pouch. 2019-08-21
2018-03-30 Class II Packaging process control The affected products were inadvertently packaged with the inner packaging pouch being sealed together with the outer pouch. 47 units 2019-08-21
2018-03-30 Class II Packaging process control The affected products were inadvertently packaged with the inner packaging pouch being sealed together with the outer pouch. 72 units 2019-08-21
2018-03-30 Class II Packaging process control The affected products were inadvertently packaged with the inner packaging pouch being sealed together with the outer pouch. 16 units 2019-08-21
2018-01-15 Class II Process control The affected products were inadvertently packaged with an incorrect screw component. 12 units
2017-09-14 Class II Mixed-up of materials/components The Legion Screw-on Wedge Size 4 contained 5MM screws instead of the required 10MM screw. 10 units 2020-08-21
2017-08-01 Class II Employee error Two lots of Genesis II Non Porous C/R Femoral Size 6 right packaged were distributed containing Genesis II C/R Femoral Size 4 left. 27 units 2019-02-19
2017-05-30 Class II Process control The incorrect Loctite adhesive was used to assemble the impactor heads. 36 units 2021-12-10
2017-05-30 Class II Process control The incorrect Loctite adhesive was used to assemble the impactor heads. 46 units 2021-12-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
22 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
33 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
15 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
6 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
6 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
34 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
33 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
2 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
1 unit 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
24 units 2017-04-10
2016-03-11 Class II Process control The Affected Devices may contain a dimensional deviation that could potentially result in the
surgeon being unable to seat the polyethylene (PE) Insert on the affected VKS tibial base
plate during surgery.
1 unit 2017-04-10

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer