Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

Tibial Sleeve Broach 52mm M-L 31mm A-P

Registry build 21.09.26
21manufacturers in China registered for this device type
109catalogue numbers in this listing
15510(k) clearances naming this product code
14recalls on this code

Who Else Makes It

Concentrated in Jiangsu (10), Shanghai (4), Beijing (3). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JWH
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Changzhou Wastonortho Medical Appliance Co., Ltd. Changzhou Jiangsu Contract manufacturer 5

Showing 12 of 21. All 21 manufacturers in China registered for Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

Record

Regulatory record for Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
Listed by Ortho Development Corp., United States
FDA product code JWH
Device type Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3560
Establishment Specification developer, Complaint-file establishment, Manufacturer, Exporter
510(k) K181569
Record published 2023-11-01
Record revised 2022-03-22 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Label carries lot or batch number, manufacturing date
Sizes Height 7 to 20 mm; length 31 to 68 mm; width 28 to 36 mm

Catalogue Numbers

Catalogue numbers for Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
Catalogue number Size Status
266-8616 Height 16 mm In distribution
266-8110 Height 10 mm In distribution
266-8710 Height 10 mm In distribution
661-5252A Length 52 mm In distribution
266-8614 Height 14 mm In distribution
266-8118 Height 18 mm In distribution
662-5252A Width 31 mm In distribution
266-8416 Height 16 mm In distribution
266-8408 Height 8 mm In distribution
C-1-11705-508 Height 8 mm In distribution
266-8409 Height 9 mm In distribution
266-8514 Height 14 mm In distribution
266-8712 Height 12 mm In distribution
266-8516 Height 16 mm In distribution
266-8314 Height 14 mm In distribution
266-8312 Height 12 mm In distribution
266-8613 Height 13 mm In distribution
C-1-11705-209 Height 9 mm In distribution
266-8111 Height 11 mm In distribution
266-8413 Height 13 mm In distribution
266-8114 Height 14 mm In distribution
266-8220 Height 20 mm In distribution
C-1-11705-409 Height 9 mm In distribution
266-8609 Height 9 mm In distribution
661-5234A Length 34 mm In distribution
C-1-11705-208 Height 8 mm In distribution
266-8108 Height 8 mm In distribution
266-8708 Height 8 mm In distribution
266-8718 Height 18 mm In distribution
266-8414 Height 14 mm In distribution
C-1771 In distribution
266-8509 Height 9 mm In distribution
266-8508 Height 8 mm In distribution
266-8520 Height 20 mm In distribution
266-8512 Height 12 mm In distribution
C-1-11705-607 Height 7 mm In distribution
266-8318 Height 18 mm In distribution
C-1-11705-410 Height 10 mm In distribution
266-8207 Height 7 mm In distribution
266-8407 Height 7 mm In distribution
266-8513 Height 13 mm In distribution
266-8112 Height 12 mm In distribution
266-8212 Height 12 mm In distribution
266-8707 Height 7 mm In distribution
266-8612 Height 12 mm In distribution
266-8320 Height 20 mm In distribution
266-8316 Height 16 mm In distribution
C-1-11705-509 Height 9 mm In distribution
266-8307 Height 7 mm In distribution
266-8713 Height 13 mm In distribution
266-8412 Height 12 mm In distribution
662-5260A Length 60 mm In distribution
661-5231A Length 31 mm In distribution
266-8607 Height 7 mm In distribution
C-1-11705-510 Height 10 mm In distribution
266-8618 Height 18 mm In distribution
266-8420 Height 20 mm In distribution
266-8211 Height 11 mm In distribution
266-8308 Height 8 mm In distribution
C-1-11705-407 Height 7 mm In distribution
662-5240A Length 40 mm In distribution
266-8510 Height 10 mm In distribution
266-8610 Height 10 mm In distribution
C-1-11705-608 Height 8 mm In distribution
662-5245A Length 45 mm In distribution
266-8208 Height 8 mm In distribution
266-8214 Height 14 mm In distribution
266-8309 Height 9 mm In distribution
266-8714 Height 14 mm In distribution
266-8611 Height 11 mm In distribution
266-8120 Height 20 mm In distribution
266-8711 Height 11 mm In distribution
C-1-11705-507 Height 7 mm In distribution
266-8210 Height 10 mm In distribution
C-1-11705-207 Height 7 mm In distribution
C-1-11705-210 Height 10 mm In distribution
661-5246A Length 46 mm In distribution
266-8311 Height 11 mm In distribution
266-8518 Height 18 mm In distribution
266-8213 Height 13 mm In distribution
C-1-11705-610 Height 10 mm In distribution
662-5268A Length 68 mm In distribution
266-8411 Height 11 mm In distribution
266-8109 Height 9 mm In distribution
266-8720 Height 20 mm In distribution
266-8310 Height 10 mm In distribution
266-8410 Height 10 mm In distribution
266-8313 Height 13 mm In distribution
266-8209 Height 9 mm In distribution
C-1-11705-408 Height 8 mm In distribution
266-8113 Height 13 mm In distribution
266-8511 Height 11 mm In distribution
C-1-11705-309 Height 9 mm In distribution
266-8116 Height 16 mm In distribution
266-8716 Height 16 mm In distribution
266-8216 Height 16 mm In distribution
266-8507 Height 7 mm In distribution
C-1-11705-609 Height 9 mm In distribution
C-1-11705-307 Height 7 mm In distribution
266-8218 Height 18 mm In distribution
266-8620 Height 20 mm In distribution
266-8107 Height 7 mm In distribution
661-5240A Length 40 mm In distribution
266-8608 Height 8 mm In distribution
266-8418 Height 18 mm In distribution
266-8709 Height 9 mm In distribution
C-1-11705-308 Height 8 mm In distribution
661-5258A Length 58 mm In distribution
C-1-11705-310 Height 10 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Prophecy® Microport Orthopedics Inc. 4,423
Exult Knee Replacement System Corentec Co., Ltd. 1,770
Freedom Maxx Orthopedics Inc. 1,693
Legion Smith & Nephew, Inc. 1,534
MyKnee Medacta International SA 1,466
Journey Smith & Nephew, Inc. 1,339
Persona® Zimmer, Inc. 1,254
DJO Surgical Encore Medical, L.P. 1,131
U2 Total Knee System United Orthopedic Corp. 1,078
CKS Plus Shalby Advanced Technologies, Inc. 1,024
Lospa Modular Knee System Corentec Co., Ltd. 1,020
Natural-Knee® Zimmer, Inc. 980

Showing 12 of 1,175. All products under Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K242984 2024-10-25
K233093 2023-10-25
K182085 2018-10-31
K181569 2018-10-12
K180743 2018-06-20
K152169 2015-10-27
K133449 2014-02-18
K131337 2013-10-11
K123457 2013-03-22
K103837 2011-03-24
K090705 2009-10-09
K060569 2006-07-06
K031201 2003-07-15
K020383 2002-05-06
K994370 2000-03-24

Recalls

7 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2019-05-30 Class II Nonconforming Material/Component The locking mechanism of the tibial tray exhibited a
manufacturing defect in which a uniform ridge was cut along the inner wall of the “T” and “Y” junctions, which may cause resistance when the Tibial Insert was being assembled.
29
2019-05-30 Class II Nonconforming Material/Component The locking mechanism of the tibial tray exhibited a
manufacturing defect in which a uniform ridge was cut along the inner wall of the “T” and “Y” junctions, which may cause resistance when the Tibial Insert was being assembled.
27
2014-07-11 Class II Packaging process control Ortho Development is recalling various Pivot Bipolar Cup, Patella, PS Tibial Insert, UC Tibila Insert, and CK Tibil Insert because the foil pouches did not properly seal, allowing air to seep back into the pouch after sealing which increase 13 2014-10-06
2014-07-11 Class II Packaging process control Ortho Development is recalling various Pivot Bipolar Cup, Patella, PS Tibial Insert, UC Tibila Insert, and CK Tibil Insert because the foil pouches did not properly seal, allowing air to seep back into the pouch after sealing which increase 14 2014-10-06
2014-07-11 Class II Packaging process control Ortho Development is recalling various Pivot Bipolar Cup, Patella, PS Tibial Insert, UC Tibila Insert, and CK Tibil Insert because the foil pouches did not properly seal, allowing air to seep back into the pouch after sealing which increase 1 2014-10-06
2014-07-11 Class II Packaging process control Ortho Development is recalling various Pivot Bipolar Cup, Patella, PS Tibial Insert, UC Tibila Insert, and CK Tibil Insert because the foil pouches did not properly seal, allowing air to seep back into the pouch after sealing which increase 11 2014-10-06
2014-04-01 Class II Process control A femoral component containing pegs was found in a box for the pegless version. 5 2014-07-14
2011-01-07 Not classified Error in labeling Components of a replacement knee system could be mislabeled. 14 units (US), 2 (Intnl) 2011-12-27
2011-01-07 Not classified Error in labeling Components of a replacement knee system could be mislabeled. 25 units 2011-12-27
2011-01-07 Not classified Error in labeling Components of a replacement knee system could be mislabeled. 33 units (US) 2011-12-27
2009-05-29 Not classified Mixed-up of materials/components Erroneous lot number on 3 of 28 units of Balanced Knee System. Three units from Lot Number 0055245 were mixed in with the recalled lot (0054891). 13 units 2010-05-11
2009-03-19 Not classified Device Design A component of knee prosthesis was assembled incorrectly. 368 units 2010-06-30
2009-03-19 Not classified Device Design A component of knee prosthesis was assembled incorrectly. 422 units 2010-06-30
2003-09-15 Not classified Other The guide pin which rotationally constrains the tibial punch within the punch guide, may fall out. 27 2003-12-11

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer