Signature
SIG C/T TKA GDE/MDL SET 04-05
Who Else Makes It
Concentrated in Jiangsu (10), Shanghai (4), Beijing (3). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Guangzhou Aquila Precise Tools Limited | Guangzhou | Guangdong | Contract manufacturer | 28 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 10 |
| b-ONE Medical (Beijing) Co., Ltd. | Beijing | Beijing | Contract manufacturer | 7 |
| Changzhou Wastonortho Medical Appliance Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 5 |
Showing 12 of 21. All 21 manufacturers in China registered for Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
Record
| Listed by | Materialise NV, Belgium |
|---|---|
| FDA product code | JWH |
| Device type | Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3560 |
| 510(k) | K102795 |
| Record published | 2016-09-24 |
| Record revised | 2024-08-20 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization, Hydrogen Peroxide |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Distribution end date | 2019-03-01 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 42-422560 | Withdrawn | |
| 42-422761 | Withdrawn | |
| 42-422556 | Withdrawn | |
| 42-422760 | Withdrawn | |
| 42-422553 | Withdrawn | |
| 42-422566 | Withdrawn | |
| 42-422567 | Withdrawn | |
| 42-422772 | Withdrawn | |
| 42-411563 | Withdrawn | |
| 42-422557 | Withdrawn | |
| 42-422763 | Withdrawn | |
| 42-422565 | Withdrawn | |
| 42-411560 | Withdrawn | |
| 42-422578 | Withdrawn | |
| 42-422552 | Withdrawn | |
| 42-422551 | Withdrawn | |
| 42-422575 | Withdrawn | |
| 42-411570 | Withdrawn | |
| 42-422770 | Withdrawn | |
| 42-422568 | Withdrawn | |
| 42-422753 | Withdrawn | |
| 42-411574 | Withdrawn | |
| 42-411562 | Withdrawn | |
| 42-422410 | Withdrawn | |
| 42-422563 | Withdrawn | |
| 42-422555 | Withdrawn | |
| Signature Planner | Withdrawn | |
| 42-411572 | Withdrawn | |
| 42-422751 | Withdrawn | |
| 42-422571 | Withdrawn | |
| 42-422573 | Withdrawn | |
| 42-433410 | Withdrawn | |
| 42-411564 | Withdrawn | |
| 42-422577 | Withdrawn | |
| 42-422577 | Withdrawn | |
| 42-422762 | Withdrawn | |
| 42-422561 | Withdrawn | |
| 42-422771 | Withdrawn | |
| 42-422562 | Withdrawn | |
| 42-411573 | Withdrawn | |
| 42-422576 | Withdrawn | |
| 42-422572 | Withdrawn | |
| 42-422752 | Withdrawn | |
| 42-411561 | Withdrawn | |
| 42-422750 | Withdrawn | |
| 42-422773 | Withdrawn | |
| 42-422558 | Withdrawn | |
| 42-422550 | Withdrawn | |
| 42-411571 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Prophecy® | Microport Orthopedics Inc. | 4,423 |
| Exult Knee Replacement System | Corentec Co., Ltd. | 1,770 |
| Freedom | Maxx Orthopedics Inc. | 1,693 |
| Legion | Smith & Nephew, Inc. | 1,534 |
| MyKnee | Medacta International SA | 1,466 |
| Journey | Smith & Nephew, Inc. | 1,339 |
| Persona® | Zimmer, Inc. | 1,254 |
| DJO Surgical | Encore Medical, L.P. | 1,131 |
| U2 Total Knee System | United Orthopedic Corp. | 1,078 |
| CKS Plus | Shalby Advanced Technologies, Inc. | 1,024 |
| Lospa Modular Knee System | Corentec Co., Ltd. | 1,020 |
| Natural-Knee® | Zimmer, Inc. | 980 |
Showing 12 of 1,175. All products under Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K253793 | 2026-01-06 |
| K251554 | 2025-07-14 |
| K221337 | 2022-07-05 |
| K173445 | 2018-02-02 |
| K162273 | 2016-11-07 |
| K150928 | 2015-08-10 |
| K140027 | 2014-05-22 |
| K133162 | 2014-02-25 |
| K121640 | 2012-12-05 |
| K113829 | 2012-04-02 |
| K111492 | 2011-10-13 |
| K102795 | 2011-02-02 |
| K091263 | 2009-11-19 |
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Materialise USA, LLC. | 510(k) number | 2016-05-03 | Class II | Process control | A patient specific case of Signature Personalized Patient Care System Knee Guides included a femur guide which does not match the patient associated with the case. If the issue is not identified prior to surgery, the personalized patient sp | 1 | 2016-06-28 |
| Materialise N.V. | 510(k) number | 2015-02-04 | Class II | Employee error | Images belonging to a different patient were used for the production of the patient specific surgical guide. The incorrect guide may cause a delay in surgery to accommodate the preparation and use of traditional instrumentation. | 1 unit | 2015-10-30 |
| Materialise USA, LLC. | 510(k) number | 2013-11-26 | Class II | Nonconforming Material/Component | Shipped femur guide contained a non-conformance which could possibly impact fit of the drill insert. | 1 | 2014-01-14 |
| Biomet, Inc. | 510(k) number | 2011-08-04 | Not classified | Labeling mix-ups | Biomet has initiated this action following investigation that identified two (2) specific lots of part number 42-422561 were incorrectly labeled. One (1) unit (lot 025640) was received back from distributor’s office as a product complaint. | 2 units | 2012-09-06 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.