Vanguard® Premier™
Catalogue number 599312, listed by Biomet Orthopedics, United States, under Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer. 21 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (10), Shanghai (4), Beijing (3). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Guangzhou Aquila Precise Tools Limited | Guangzhou | Guangdong | Contract manufacturer | 28 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 10 |
| b-ONE Medical (Beijing) Co., Ltd. | Beijing | Beijing | Contract manufacturer | 7 |
| Changzhou Wastonortho Medical Appliance Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 5 |
Showing 12 of 21. All 21 manufacturers in China registered for Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
Record
| Listed by | Biomet Orthopedics, United States |
|---|---|
| FDA product code | JWH |
| Device type | Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3560 |
| 510(k) | K113550 |
| Record published | 2017-07-28 |
| Record revised | 2025-05-30 (version 13) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Prescription | Prescription only |
| Label carries | lot or batch number, manufacturing date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 599312 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Prophecy® | Microport Orthopedics Inc. | 4,423 |
| Exult Knee Replacement System | Corentec Co., Ltd. | 1,770 |
| Freedom | Maxx Orthopedics Inc. | 1,693 |
| Legion | Smith & Nephew, Inc. | 1,534 |
| MyKnee | Medacta International SA | 1,466 |
| Journey | Smith & Nephew, Inc. | 1,339 |
| Persona® | Zimmer, Inc. | 1,254 |
| DJO Surgical | Encore Medical, L.P. | 1,131 |
| U2 Total Knee System | United Orthopedic Corp. | 1,078 |
| CKS Plus | Shalby Advanced Technologies, Inc. | 1,024 |
| Lospa Modular Knee System | Corentec Co., Ltd. | 1,020 |
| Natural-Knee® | Zimmer, Inc. | 980 |
Showing 12 of 1,175. All products under Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K080528 | 2008-06-17 |
| K022586 | 2002-08-15 |
Recalls Naming This Product
7 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Biomet, Inc. | 510(k) number | 2022-12-29 | Class II | Labeling Change Control | Components Incorrectly labeled as either smaller or larger and incorrect side (right/left). | 157 units | |
| Biomet, Inc. | 510(k) number | 2022-12-29 | Class II | Labeling Change Control | Components Incorrectly labeled as either smaller or larger and incorrect side (right/left). | 91 units | |
| Biomet, Inc. | 510(k) number | 2018-10-22 | Class II | Labeling mix-ups | Label on the outer carton or the patient labels does not match label on the inner sterile packaging | 8 units | 2019-12-11 |
| Biomet, Inc. | 510(k) number | 2018-10-22 | Class II | Labeling mix-ups | Label on the outer carton or the patient labels does not match label on the inner sterile packaging | 8 units | 2019-12-11 |
| Biomet, Inc. | 510(k) number | 2018-05-24 | Class II | Under Investigation by firm | Two lots of tibial bearings were commingled. There is a possibility that a 14mm tibial bearing is packaged in a box labeled as 12 mm tibial bearing and vice versa. This may lead to extension of surgery to find another implant. | 48 | 2020-04-07 |
| Biomet, Inc. | 510(k) number | 2018-05-11 | Class II | Under Investigation by firm | The label master file was errantly set up as a 63/37mm instead of a 63/67mm. There is no 63/37 size offered, and the product is laser marked with the correct size. | 169 | 2019-11-21 |
| Biomet, Inc. | 510(k) number | 2017-10-03 | Class II | Error in labeling | The affected products are labeled as a 62.5mm LEFT Femur; however, the contents are a Vanguard 70mm RIGHT Femur. | 8 | 2018-08-23 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.