Vanguard XP® Complete Knee System

13 catalogue numbers from 195269, listed by Biomet Orthopedics, United States, under Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer. 21 manufacturers in China are registered for this product code.

Registry build 21.09.26
21manufacturers in China registered for this device type
13catalogue numbers in this listing
2510(k) clearances naming this product code

Who Else Makes It

Concentrated in Jiangsu (10), Shanghai (4), Beijing (3). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JWH
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Changzhou Wastonortho Medical Appliance Co., Ltd. Changzhou Jiangsu Contract manufacturer 5

Showing 12 of 21. All 21 manufacturers in China registered for Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

Record

Regulatory record for Vanguard XP® Complete Knee System
Listed by Biomet Orthopedics, United States
FDA product code JWH
Device type Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3560
510(k) K132873
Record published 2025-12-23

Specifications

Specifications
MRI safety MR Conditional
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for Vanguard XP® Complete Knee System
Catalogue number Size Status
195269 63 MM In distribution
195270 65 MM In distribution
195758 79 MM In distribution
195913 72.5 MM In distribution
195916 80 MM In distribution
195915 77.5 MM In distribution
195926 75 MM In distribution
195756 73 MM In distribution
195928 80 MM In distribution
195925 72.5 MM In distribution
195911 67.5 MM In distribution
195272 69 MM In distribution
195923 67.5 MM In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Prophecy® Microport Orthopedics Inc. 4,423
Exult Knee Replacement System Corentec Co., Ltd. 1,770
Freedom Maxx Orthopedics Inc. 1,693
Legion Smith & Nephew, Inc. 1,534
MyKnee Medacta International SA 1,466
Journey Smith & Nephew, Inc. 1,339
Persona® Zimmer, Inc. 1,254
DJO Surgical Encore Medical, L.P. 1,131
U2 Total Knee System United Orthopedic Corp. 1,078
CKS Plus Shalby Advanced Technologies, Inc. 1,024
Lospa Modular Knee System Corentec Co., Ltd. 1,020
Natural-Knee® Zimmer, Inc. 980

Showing 12 of 1,175. All products under Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K080528 2008-06-17
K022586 2002-08-15

Recalls Naming This Product

23 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Vanguard XP® Complete Knee System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 322 unit 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 375 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 567 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 498 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 454 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 327 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 369 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 319 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 180 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 78 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 82 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 86 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 90 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 384 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 973 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 906 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 1221 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 1282 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 1210 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 857 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 480 units 2021-04-16
Biomet, Inc. 510(k) number 2016-02-05 Class II Device Design The anterior/posterior (AP) dimension may be oversized by 0.016.
If the femoral component does not fit as tightly as intended, bony ingrowth may not occur causing loosening of the femoral component. A revision surgery may be necessary.
890 2017-03-28

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer