Anatomic Shoulder TM Combined System

The Anatomical Shoulder Combined System brings together humeral stems, Bigliani/Flatow heads and glenoid components for conventional hemi or total shoulder arthroplasty. The range includes…

Registry build 21.09.26

The Anatomical Shoulder Combined System brings together humeral stems, Bigliani/Flatow heads and glenoid components for conventional hemi or total shoulder arthroplasty. The range includes cemented, uncemented and fracture stems, polyethylene glenoids and Trabecular Metal glenoids.

An AS Bigliani/Flatow adaptor connects the Anatomical Shoulder stem to a Bigliani/Flatow humeral head. Its two taper interfaces match the stem and head systems, allowing those components to form the humeral assembly.

Materials and Fixation

Cemented humeral stems and heads are cobalt-chromium-molybdenum alloys. Uncemented and fracture stems and the adaptor are titanium alloy. Bigliani/Flatow glenoids are UHMWPE; Trabecular Metal glenoids combine that polymer with Trabecular Metal.

Standard cemented and revision stems use cement, standard uncemented stems use cementless fixation, and fracture stems permit either. The specified glenoid components are intended for cemented use.

6manufacturers in China registered for this device type
3catalogue numbers in this listing
8510(k) clearances naming this product code
20recalls on this code

Who Else Makes It

Concentrated in Jiangsu (3), Shanghai (2), Zhejiang (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code KWT
Manufacturer City Province Registered as Device types
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34

Record

Regulatory record for Anatomic Shoulder TM Combined System
Listed by Zimmer, Inc., United States
FDA product code KWT
Device type Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented
Device class Class 2
Regulation 21 CFR 888.3650
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K103404
Record published 2018-03-26
Record revised 2019-04-08 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries serial number
Sizes Width 46 mm

Catalogue Numbers

Catalogue numbers for Anatomic Shoulder TM Combined System
Catalogue number Size Status
SSI004358 Sz 40 In distribution
SSI004361 Sz 52 In distribution
82-0180-119-46 Width 46 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Equinoxe Exactech, Inc. 336
SMR Shoulder Limacorporate 289
Tornier Perform Humeral System Tornier Inc. 119
Bigliani/Flatow® Zimmer, Inc. 119
Trabecular Metal® Zimmer, Inc. 115
Jarvis Glenoid Rerverse Shoulder Prosthesis Fournitures Hospitalieres Industrie 103
Comprehensive® Shoulder System Biomet Orthopedics 86
Alliance® Zimmer, Inc. 68
Anatomical Shoulder™ Zimmer, Inc. 54
Aetos Shoulder System Smith & Nephew, Inc. 53
Perform™ Humeral System Tornier Inc. 47
Bio-Modular® Shoulder System Biomet Orthopedics 43

Showing 12 of 164. All products under Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K150730 2015-06-16
K121543 2012-10-11
K110791 2011-09-02
K103404 2011-03-15
K050761 2005-04-11
K041549 2004-09-01
K982981 1998-12-17
K790987 1979-06-22

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Anatomic Shoulder TM Combined System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Zimmer, Inc. 510(k) number 2012-05-12 Class II Mixed-up of materials/components Bigliani/Flatow The Complete Shoulder Solution Trabecular Metal Glenoid Instrument Drill with Stop, 6 mm. Catalog number 47-4301-031-00 was actually packaged and labeled as catalog number 47-4307-031-00, lot 62071190. 87 units 2013-09-12

Recalls

9 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2019-10-10 Class II Packaging change control Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). 5,459,583 total devices 2020-05-19
2019-10-10 Class II Packaging change control Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). 5,459,583 total devices 2020-05-19
2019-10-10 Class II Packaging change control Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). 5,459,583 total devices 2020-05-19
2017-05-22 Class II Process control Various trauma and extremity instruments (drill bits and screw taps) were manufactured from raw material with an anomaly. The anomaly may be on or below the surface and can increase the risk of instrument fracture. 2825 units 2019-03-29
2014-01-10 Class II Nonconforming Material/Component This single manufacturing lot has the potential for the bond strength between the Trabecular Metal material and substrate to be below the minimum required specification. Testing found bond strength approximately 80% of the minimum required 10 units 2014-09-11
2013-12-10 Class II Labeling mix-ups Zimmer is initiating a lot specific recall of the CPT Hip Stem, Versys Build-Up Block, and Trabecular Metal Reverse Glenosphere medical devices due to reports of the products being packaged in the incorrect outer carton. Product labels and 25 2014-09-11
2013-10-17 Class II Device Design As a result of complaints for disassociation of the TM Reverse Glenosphere from the Baseplate, Zimmer updated the related surgical technique and released a video to provide additional instructions to users on how to properly assemble the Gl 73,002 units 2014-09-12
2013-08-01 Class II Device Design Zimmer is initiating a lot specific recall of the Trabecular Metal” Reverse Glenosphere Distractor due to the potential of the device not functioning properly should it be utilized without proper lubrication. As a result, there is a potenti 771 2015-03-02
2012-09-04 Class II Error in labeling Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient 45 USA 2014-04-16
2010-09-10 Not classified Device Design The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela 2012-09-14
2010-09-10 Not classified Device Design The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela 9,790 total distal pilots in distribution. 2012-09-14
2010-09-10 Not classified Device Design The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela 13,093 total reamers in distribution. 2012-09-14
2010-09-10 Not classified Device Design The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela 13,093 total reamers in distribution. 2012-09-14
2010-09-10 Not classified Device Design The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela 2012-09-14
2010-09-10 Not classified Device Design The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela 9,790 total distal pilots in distribution. 2012-09-14
2010-09-10 Not classified Device Design The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela 2012-09-14
2006-07-20 Not classified Other Components may not lock together as intended. 197 for all three recalls Z-1416-1418-06 2007-12-19
2006-07-20 Not classified Other Components may not lock together as intended. 197 for all three recalls Z-1416-1418-06 2007-12-19
2006-07-20 Not classified Other Components may not lock together as intended. 197 for all three recalls Z-1416-1418-06 2007-12-19

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer