| 2019-10-10 | Class II | Packaging change control | Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). | 5,459,583 total devices | 2020-05-19 |
| 2019-10-10 | Class II | Packaging change control | Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). | 5,459,583 total devices | 2020-05-19 |
| 2019-10-10 | Class II | Packaging change control | Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). | 5,459,583 total devices | 2020-05-19 |
| 2017-05-22 | Class II | Process control | Various trauma and extremity instruments (drill bits and screw taps) were manufactured from raw material with an anomaly. The anomaly may be on or below the surface and can increase the risk of instrument fracture. | 2825 units | 2019-03-29 |
| 2014-01-10 | Class II | Nonconforming Material/Component | This single manufacturing lot has the potential for the bond strength between the Trabecular Metal material and substrate to be below the minimum required specification. Testing found bond strength approximately 80% of the minimum required | 10 units | 2014-09-11 |
| 2013-12-10 | Class II | Labeling mix-ups | Zimmer is initiating a lot specific recall of the CPT Hip Stem, Versys Build-Up Block, and Trabecular Metal Reverse Glenosphere medical devices due to reports of the products being packaged in the incorrect outer carton. Product labels and | 25 | 2014-09-11 |
| 2013-10-17 | Class II | Device Design | As a result of complaints for disassociation of the TM Reverse Glenosphere from the Baseplate, Zimmer updated the related surgical technique and released a video to provide additional instructions to users on how to properly assemble the Gl | 73,002 units | 2014-09-12 |
| 2013-08-01 | Class II | Device Design | Zimmer is initiating a lot specific recall of the Trabecular Metal” Reverse Glenosphere Distractor due to the potential of the device not functioning properly should it be utilized without proper lubrication. As a result, there is a potenti | 771 | 2015-03-02 |
| 2012-09-04 | Class II | Error in labeling | Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient | 45 USA | 2014-04-16 |
| 2012-05-12 | Class II | Mixed-up of materials/components | Bigliani/Flatow The Complete Shoulder Solution Trabecular Metal Glenoid Instrument Drill with Stop, 6 mm. Catalog number 47-4301-031-00 was actually packaged and labeled as catalog number 47-4307-031-00, lot 62071190. | 87 units | 2013-09-12 |
| 2010-09-10 | Not classified | Device Design | The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela | | 2012-09-14 |
| 2010-09-10 | Not classified | Device Design | The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela | 9,790 total distal pilots in distribution. | 2012-09-14 |
| 2010-09-10 | Not classified | Device Design | The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela | 13,093 total reamers in distribution. | 2012-09-14 |
| 2010-09-10 | Not classified | Device Design | The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela | 13,093 total reamers in distribution. | 2012-09-14 |
| 2010-09-10 | Not classified | Device Design | The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela | | 2012-09-14 |
| 2010-09-10 | Not classified | Device Design | The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela | 9,790 total distal pilots in distribution. | 2012-09-14 |
| 2010-09-10 | Not classified | Device Design | The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela | | 2012-09-14 |
| 2006-07-20 | Not classified | Other | Components may not lock together as intended. | 197 for all three recalls Z-1416-1418-06 | 2007-12-19 |
| 2006-07-20 | Not classified | Other | Components may not lock together as intended. | 197 for all three recalls Z-1416-1418-06 | 2007-12-19 |
| 2006-07-20 | Not classified | Other | Components may not lock together as intended. | 197 for all three recalls Z-1416-1418-06 | 2007-12-19 |