Comprehensive Modular Hybrid Glenoid

6 catalogue numbers from SSI001961, listed by Biomet Orthopedics, United States, under Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented. 6 manufacturers in China are registered for this product code.

Registry build 21.09.26
6manufacturers in China registered for this device type
6catalogue numbers in this listing
3510(k) clearances naming this product code

Who Else Makes It

Concentrated in Jiangsu (3), Shanghai (2), Zhejiang (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code KWT
Manufacturer City Province Registered as Device types
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34

Record

Regulatory record for Comprehensive Modular Hybrid Glenoid
Listed by Biomet Orthopedics, United States
FDA product code KWT
Device type Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented
Device class Class 2
Regulation 21 CFR 888.3650
510(k) K060694
Record published 2017-06-19
Record revised 2025-05-30 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Comprehensive Modular Hybrid Glenoid
Catalogue number Size Status
SSI001961 Medium In distribution
SSI001912 Large In distribution
SSI002230 Small In distribution
SSI003626 In distribution
SSI002232 Large In distribution
SSI000916 Small In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Equinoxe Exactech, Inc. 336
SMR Shoulder Limacorporate 289
Tornier Perform Humeral System Tornier Inc. 119
Bigliani/Flatow® Zimmer, Inc. 119
Trabecular Metal® Zimmer, Inc. 115
Jarvis Glenoid Rerverse Shoulder Prosthesis Fournitures Hospitalieres Industrie 103
Comprehensive® Shoulder System Biomet Orthopedics 86
Alliance® Zimmer, Inc. 68
Anatomical Shoulder™ Zimmer, Inc. 54
Aetos Shoulder System Smith & Nephew, Inc. 53
Perform™ Humeral System Tornier Inc. 47
Bio-Modular® Shoulder System Biomet Orthopedics 43

Showing 12 of 164. All products under Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K223631 2023-07-12
K023063 2002-12-13
K020045 2002-01-30

Recalls Naming This Product

4 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Comprehensive Modular Hybrid Glenoid
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Biomet, Inc. 510(k) number 2017-04-26 Class II Under Investigation by firm Zimmer Biomet is conducting a voluntary recall for a single lot of the Modular Hybrid Glenoid Base Large for the Comprehensive Shoulder System after it was determined that two pieces from the lot were moved to finished goods and shipped des 16 2018-03-30
Biomet, Inc. 510(k) number 2017-02-17 Class II Process design Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components. 28,253 in total 2018-01-29
Biomet, Inc. 510(k) number 2008-03-13 Not classified Device Design The glenoid implant may not seat fully on the face of the natural glenoid due to inadequate measurement tolerances (tolerance stack-up) in the design of the cutter. Use of the instrument may lead to incomplete seating of the glenoid implan 189 2008-10-15
Biomet, Inc. 510(k) number 0012-12-06 Class II Nonconforming Material/Component Biomet is recalling Part Number PT-113950 PT Hybrid Glenoid Post, following an investigation which identified that the male thread of the post may be oversized. This oversized condition can vary in degree and may lead to the following thre 1050 2013-11-08

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer