Comprehensive® SRS / Discovery®
Catalogue number 211254, listed by Biomet Orthopedics, United States, under Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented. 6 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (3), Shanghai (2), Zhejiang (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
Record
| Listed by | Biomet Orthopedics, United States |
|---|---|
| FDA product code | KWT |
| Device type | Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3650 |
| 510(k) | K111746 |
| Record published | 2017-03-20 |
| Record revised | 2025-05-30 (version 5) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 211254 | 60 MM | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Equinoxe | Exactech, Inc. | 336 |
| SMR Shoulder | Limacorporate | 289 |
| Tornier Perform Humeral System | Tornier Inc. | 119 |
| Bigliani/Flatow® | Zimmer, Inc. | 119 |
| Trabecular Metal® | Zimmer, Inc. | 115 |
| Jarvis Glenoid Rerverse Shoulder Prosthesis | Fournitures Hospitalieres Industrie | 103 |
| Comprehensive® Shoulder System | Biomet Orthopedics | 86 |
| Alliance® | Zimmer, Inc. | 68 |
| Anatomical Shoulder™ | Zimmer, Inc. | 54 |
| Aetos Shoulder System | Smith & Nephew, Inc. | 53 |
| Perform™ Humeral System | Tornier Inc. | 47 |
| Bio-Modular® Shoulder System | Biomet Orthopedics | 43 |
Showing 12 of 164. All products under Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K223631 | 2023-07-12 |
| K023063 | 2002-12-13 |
| K020045 | 2002-01-30 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Biomet, Inc. | 510(k) number | 2018-02-28 | Class II | Under Investigation by firm | During assembly, an SRS Humeral Distal Body implant failed to engage correctly at the point of reduction with a Discovery Elbow System Humeral Condyle. A mismatch between the screw holes in the Humeral Body & Elbow Condyle affects assembly | 634 | 2020-08-11 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.