SMR System

SMR System - Adaptor Taper Eccentrical 4mm Long

Registry build 21.09.26
6manufacturers in China registered for this device type
31catalogue numbers in this listing

Who Else Makes It

Concentrated in Jiangsu (3), Shanghai (2), Zhejiang (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code KWT
Manufacturer City Province Registered as Device types
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34

Record

Regulatory record for SMR System
Listed by Limacorporate, Italy
FDA product code KWT
Device type Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented
Device class Class 2
Regulation 21 CFR 888.3650
510(k) K100858
Record published 2025-06-10
Record revised 2025-03-06 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for SMR System
Catalogue number Size Status
9013.22.202 In distribution
1330.15.272 Eccentrical 2mm In distribution
1375.15.610 Standard In distribution
1322.09.500 Dia. 50 mm In distribution
1331.15.274 Eccentrical 4mm Long In distribution
1375.15.605 Small-R In distribution
1330.15.270 Neutral In distribution
1306.15.180 Dia. 18 mm L. 80 mm In distribution
1322.09.480 Dia. 48 mm In distribution
1331.15.278 Eccentrical 8mm Long In distribution
1322.09.460 Dia. 46 mm In distribution
1322.09.520 Dia. 52 mm In distribution
1306.15.200 Dia. 20 mm L. 80 mm In distribution
1322.09.400 Dia 40mm In distribution
1331.15.272 Eccentrical 2mm Long In distribution
1322.09.540 Dia. 54 mm In distribution
1306.15.160 Dia. 16 mm L. 80 mm In distribution
1375.15.620 Small In distribution
1306.15.120 Dia. 12 mm L. 80 mm In distribution
1350.15.020 Long In distribution
1350.15.010 Medium In distribution
1322.09.420 Dia. 42 mm In distribution
1330.15.274 Eccentrical 4mm In distribution
1306.15.140 Dia. 14 mm L. 80 mm In distribution
9075.10.135 In distribution
1322.09.440 Dia. 44 mm In distribution
9013.22.201 In distribution
1331.15.270 Long Neutral In distribution
9013.22.200 In distribution
1350.15.030 Short In distribution
1330.15.278 Eccentrical 8mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Equinoxe Exactech, Inc. 336
SMR Shoulder Limacorporate 289
Tornier Perform Humeral System Tornier Inc. 119
Bigliani/Flatow® Zimmer, Inc. 119
Trabecular Metal® Zimmer, Inc. 115
Jarvis Glenoid Rerverse Shoulder Prosthesis Fournitures Hospitalieres Industrie 103
Comprehensive® Shoulder System Biomet Orthopedics 86
Alliance® Zimmer, Inc. 68
Anatomical Shoulder™ Zimmer, Inc. 54
Aetos Shoulder System Smith & Nephew, Inc. 53
Perform™ Humeral System Tornier Inc. 47
Bio-Modular® Shoulder System Biomet Orthopedics 43

Showing 12 of 164. All products under Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented

Recalls Naming This Product

2 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of SMR System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Limacorporate S.p.A. 510(k) number 2015-08-14 Class II Nonconforming Material/Component The dimensions of the mating features of the recalled products are out of specification causing the device to be difficult to assemble. 110 units 2016-02-26
Limacorporate S.p.A. 510(k) number 2015-08-14 Class II Nonconforming Material/Component The dimensions of the mating features of the recalled products are out of specification causing the device to be difficult to assemble. 93 units 2016-02-26

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer