Echo BI-Metric HIP System
21 catalogue numbers from 192121, listed by Biomet Orthopedics, United States, under Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate. 14 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (8), Shanghai (2), Zhejiang (2). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Lincotek (Wuxi) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 7 |
| b-ONE Medical (Beijing) Co., Ltd. | Beijing | Beijing | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
Record
| Listed by | Biomet Orthopedics, United States |
|---|---|
| FDA product code | MEH |
| Device type | Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3353 |
| 510(k) | K070274 |
| Record published | 2015-10-24 |
| Record revised | 2025-05-30 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 192121 | 21 SIZE 185 MM TYPE I TAPER | In distribution |
| 192511 | 11 Size 135 mm Type I Taper | In distribution |
| 192007 | 7 Size 115 mm Type I Taper | In distribution |
| 192519 | 19 SIZE 175 MM TYPE I TAPER | In distribution |
| 192007 | 7 SIZE 115 MM TYPE I TAPER | In distribution |
| 192111 | 11 Size 135 mm Type I Taper | In distribution |
| 192407 | 7 SIZE 115 MM TYPE I TAPER | In distribution |
| 192011 | 11 Size 135 mm Type I Taper | In distribution |
| 192514 | 14 SIZE 150 MM TYPE I TAPER | In distribution |
| 192013 | 13 SIZE 145 MM TYPE I TAPER | In distribution |
| 192014 | 14 Size 150 mm Type I Taper | In distribution |
| 192012 | 12 Size 140 mm Type I Taper | In distribution |
| 192020 | 20 Size 180 mm Type I Taper | In distribution |
| 192420 | 20 SIZE 180 MM TYPE I TAPER | In distribution |
| 192410 | 10 Size 130 mm Type I Taper | In distribution |
| 192409 | 9 SIZE 125 MM TYPE I TAPER | In distribution |
| 192412 | 12 SIZE 140 MM TYPE I TAPER | In distribution |
| 192018 | 18 SIZE 170 MM TYPE I TAPER | In distribution |
| 192510 | 10 SIZE 130 MM TYPE I TAPER | In distribution |
| 192017 | 17 SIZE 165 MM TYPE I TAPER | In distribution |
| 192512 | 12 SIZE 140 MM TYPE I TAPER | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Alteon | Exactech, Inc. | 326 |
| Novation | Exactech, Inc. | 317 |
| Pinnacle | Depuy Orthopaedics, Inc. | 305 |
| SP-CL Hip Stem | Waldemar Link GmbH & Co. KG | 219 |
| Emperion | Smith & Nephew, Inc. | 201 |
| MobileLink Acetabular Cup System | Waldemar Link GmbH & Co. KG | 154 |
| Instrument | Howmedica Osteonics Corp | 145 |
| Restoration | Howmedica Osteonics Corp | 144 |
| Mfinity Femoral System | Medacta International SA | 138 |
| Echelon | Smith & Nephew, Inc. | 134 |
| Trinity Acetabular Hip System | Corin Limited | 128 |
| Redapt | Smith & Nephew, Inc. | 127 |
Showing 12 of 805. All products under Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K021403 | 2002-05-31 |
| K020963 | 2002-04-16 |
Recalls Naming This Product
3 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Biomet, Inc. | 510(k) number | 2018-06-08 | Class II | Process control | Two lots of the Echo BI-Metric Hip Stem and ARCOS Modular Revision Hip Stem may have been comingled. Potential health consequences include extension of surgery time to find a replacement component. | 12 | 2020-04-14 |
| Biomet, Inc. | 510(k) number | 2017-06-05 | Class II | Labeling False and Misleading | Possibility that the patient label inside the product box was incorrectly labeled. The outer box label and actual product are correctly identified but the internal patient label could be incorrect. | 2018-03-06 | |
| Biomet, Inc. | 510(k) number | 2012-11-06 | Class II | Labeling Change Control | It was reported that the surgeon noticed that the Echo 11mm hip stem had an etching indicating it was 13mm stem. | 4 | 2013-08-28 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.