MCS
12 catalogue numbers from 104-32-45, listed by Exactech, Inc., United States, under Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate. 14 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (8), Shanghai (2), Zhejiang (2). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Lincotek (Wuxi) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 7 |
| b-ONE Medical (Beijing) Co., Ltd. | Beijing | Beijing | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
Record
| Listed by | Exactech, Inc., United States |
|---|---|
| FDA product code | MEH |
| Device type | Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3353 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K051556 |
| Record published | 2015-10-30 |
| Record revised | 2025-08-27 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | expiry date, serial number |
| Sizes | Lumen/inner diameter 28 to 36 mm |
| Distribution end date | 2023-06-07 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 104-32-45 | 54mm/58mm Outer Diameter | Withdrawn |
| 104-28-47 | 66mm/70mm Outer Diameter | Withdrawn |
| 104-32-54 | 50mm/52mm Outer Diameter | Withdrawn |
| 104-36-46 | 60mm/64mm Outer Diameter | Withdrawn |
| 104-32-56 | 60mm/64mm Outer Diameter | Withdrawn |
| 104-36-55 | +5mm Lateralized | Withdrawn |
| 104-28-56 | 60mm/64mm Outer Diameter | Withdrawn |
| 104-32-47 | 66mm/70mm Outer Diameter | Withdrawn |
| 104-36-57 | +5mm Lateralized | Withdrawn |
| 104-28-54 | 50mm/52mm Outer Diameter | Withdrawn |
| 104-28-43 | 44mm/48mm Outer Diameter | Withdrawn |
| 104-28-45 | 54mm/58mm Outer Diameter | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Alteon | Exactech, Inc. | 326 |
| Novation | Exactech, Inc. | 317 |
| Pinnacle | Depuy Orthopaedics, Inc. | 305 |
| SP-CL Hip Stem | Waldemar Link GmbH & Co. KG | 219 |
| Emperion | Smith & Nephew, Inc. | 201 |
| MobileLink Acetabular Cup System | Waldemar Link GmbH & Co. KG | 154 |
| Instrument | Howmedica Osteonics Corp | 145 |
| Restoration | Howmedica Osteonics Corp | 144 |
| Mfinity Femoral System | Medacta International SA | 138 |
| Echelon | Smith & Nephew, Inc. | 134 |
| Trinity Acetabular Hip System | Corin Limited | 128 |
| Redapt | Smith & Nephew, Inc. | 127 |
Showing 12 of 805. All products under Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K243839 | 2025-03-10 |
| K162732 | 2017-04-26 |
| K153649 | 2016-08-31 |
| K113320 | 2012-03-16 |
| K080980 | 2008-05-06 |
| K040613 | 2004-06-04 |
| K000242 | 2000-02-16 |
| K990197 | 1999-02-04 |
Recalls Naming This Product
12 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Exactech, Inc. | 510(k) number | 2022-08-11 | Class II | Process control | Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear. | 11143 DEVICES |
| Exactech, Inc. | 510(k) number | 2021-06-29 | Class II | Unknown/Undetermined by firm | Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. | 89,050 total |
| Exactech, Inc. | 510(k) number | 2021-06-29 | Class II | Unknown/Undetermined by firm | Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. | 89,050 total |
| Exactech, Inc. | 510(k) number | 2021-06-29 | Class II | Unknown/Undetermined by firm | Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. | 89,050 total |
| Exactech, Inc. | 510(k) number | 2021-06-29 | Class II | Unknown/Undetermined by firm | Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. | 89,050 total |
| Exactech, Inc. | 510(k) number | 2021-06-29 | Class II | Unknown/Undetermined by firm | Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. | 89,050 total |
| Exactech, Inc. | 510(k) number | 2021-06-29 | Class II | Unknown/Undetermined by firm | Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. | 89,050 total |
| Exactech, Inc. | 510(k) number | 2021-06-29 | Class II | Unknown/Undetermined by firm | Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. | 89,050 total |
| Exactech, Inc. | 510(k) number | 2021-06-29 | Class II | Unknown/Undetermined by firm | Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. | 89,050 total |
| Exactech, Inc. | 510(k) number | 2021-06-29 | Class II | Unknown/Undetermined by firm | Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. | 89,050 total |
| Exactech, Inc. | 510(k) number | 2021-06-29 | Class II | Unknown/Undetermined by firm | Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. | 89,050 total |
| Exactech, Inc. | 510(k) number | 2021-06-29 | Class II | Unknown/Undetermined by firm | Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. | 89,050 total |
Recalls
3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2022-08-11 | Class II | Process control | Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear. | 136 devices | |
| 2017-10-09 | Class II | Error in labeling | Wrong device description of the label identifying the implant | 34 | 2019-08-06 |
| 2015-09-23 | Class II | Under Investigation by firm | Eight (8) pieces did not receive the specified Hydroxyapatite (HA) coating. | 8 | 2017-03-01 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.