Prosthesis Head A
Modular Prosthesis Head
Who Else Makes It
Concentrated in Jiangsu (8), Shanghai (2), Zhejiang (2). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Lincotek (Wuxi) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 7 |
| b-ONE Medical (Beijing) Co., Ltd. | Beijing | Beijing | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
Record
| Listed by | Waldemar Link GmbH & Co. KG, Germany |
|---|---|
| FDA product code | MEH |
| Device type | Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3353 |
| Establishment | Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K161840 |
| Record published | 2017-05-16 |
| Record revised | 2020-09-09 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | expiry date, manufacturing date, serial number |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 128-794/03 | In distribution | |
| 128-791/01 | In distribution | |
| 128-791/03 | In distribution | |
| 128-794/01 | In distribution | |
| 128-792/03 | In distribution | |
| 128-793/01 | In distribution | |
| 128-792/04 | In distribution | |
| 128-794/04 | In distribution | |
| 128-793/03 | In distribution | |
| 128-792/02 | In distribution | |
| 128-793/04 | In distribution | |
| 128-792/01 | In distribution | |
| 128-794/02 | In distribution | |
| 128-793/02 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Alteon | Exactech, Inc. | 326 |
| Novation | Exactech, Inc. | 317 |
| Pinnacle | Depuy Orthopaedics, Inc. | 305 |
| SP-CL Hip Stem | Waldemar Link GmbH & Co. KG | 219 |
| Emperion | Smith & Nephew, Inc. | 201 |
| MobileLink Acetabular Cup System | Waldemar Link GmbH & Co. KG | 154 |
| Instrument | Howmedica Osteonics Corp | 145 |
| Restoration | Howmedica Osteonics Corp | 144 |
| Mfinity Femoral System | Medacta International SA | 138 |
| Echelon | Smith & Nephew, Inc. | 134 |
| Trinity Acetabular Hip System | Corin Limited | 128 |
| Redapt | Smith & Nephew, Inc. | 127 |
Showing 12 of 805. All products under Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K250375 | 2025-11-05 |
| K171273 | 2018-01-19 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2018-12-04 | Class II | Employee error | The internal labeling included with these implants may include incorrect part numbers and could result in these incorrect labels being added to patient records. | 31 | 2020-06-05 |
| 2018-12-04 | Class II | Employee error | The internal labeling included with these implants may include incorrect part numbers and could result in these incorrect labels being added to patient records. | 30 | 2020-06-05 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.