Reflection

Reflection Interfit HA Acetabular Shell Three Hole Size 64MM

Registry build 21.09.26
14manufacturers in China registered for this device type
38catalogue numbers in this listing
13510(k) clearances naming this product code
5recalls on this code

Who Else Makes It

Concentrated in Jiangsu (8), Shanghai (2), Zhejiang (2). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MEH
Manufacturer City Province Registered as Device types
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
Lincotek (Wuxi) Co., Ltd. Wuxi Jiangsu Contract manufacturer 7
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate

Record

Regulatory record for Reflection
Listed by Smith & Nephew, Inc., United States
FDA product code MEH
Device type Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
Device class Class 2
Regulation 21 CFR 888.3353
Establishment Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K211176
Record published 2015-08-30
Record revised 2025-07-25 (version 10)

Specifications

Specifications
MRI safety MR Conditional
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Storage Special storage condition: : –
Sizes Length 40 mm

Catalogue Numbers

Catalogue numbers for Reflection
Catalogue number Size Status
71332515 In distribution
71334246 In distribution
71334248 In distribution
71336260 In distribution
71332545 In distribution
71336262 In distribution
71332500 In distribution
71332535 In distribution
71336246 In distribution
71332540 Length 40 mm In distribution
71332520 In distribution
71336264 In distribution
71332570 In distribution
71334254 In distribution
71336252 In distribution
71336248 In distribution
71330366 In distribution
71334260 In distribution
71336256 In distribution
71330364 In distribution
71330368 In distribution
71336254 In distribution
71332550 In distribution
71336250 In distribution
71332525 In distribution
71334264 In distribution
71334252 In distribution
71336258 In distribution
71334250 In distribution
71334262 In distribution
71336244 In distribution
71330362 In distribution
71336242 In distribution
71332530 In distribution
71334256 In distribution
71334258 In distribution
71332518 In distribution
71332560 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Alteon Exactech, Inc. 326
Novation Exactech, Inc. 317
Pinnacle Depuy Orthopaedics, Inc. 305
SP-CL Hip Stem Waldemar Link GmbH & Co. KG 219
Emperion Smith & Nephew, Inc. 201
MobileLink Acetabular Cup System Waldemar Link GmbH & Co. KG 154
Instrument Howmedica Osteonics Corp 145
Restoration Howmedica Osteonics Corp 144
Mfinity Femoral System Medacta International SA 138
Echelon Smith & Nephew, Inc. 134
Trinity Acetabular Hip System Corin Limited 128
Redapt Smith & Nephew, Inc. 127

Showing 12 of 805. All products under Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K162303 2017-05-01
K121627 2012-10-15
K113039 2012-10-05
K113789 2012-04-19
K100481 2010-07-15
K090982 2010-04-21
K081124 2008-07-31
K052426 2005-12-07
K042127 2004-11-19
K040680 2004-06-14
K023302 2002-10-25
K002996 2000-12-11
K990666 1999-08-06

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Reflection
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Smith & Nephew, Inc. 510(k) number 2016-07-06 Class II Packaging process control The labels correctly state that the product should be a 25mm screw, but the box contained a longer, 35mm screw. 185 units 2017-07-01

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2016-11-15 Class II Device Design All lots of modular neck hip prostheses are being recalled due to a higher than anticipated complaint and adverse event trend. 6266 units 2019-08-19
2016-11-15 Class II Device Design All lots of modular neck hip prostheses are being recalled due to a higher than anticipated complaint and adverse event trend. 11999 units 2019-08-19
2016-11-15 Class II Device Design All lots of modular neck hip prostheses are being recalled due to a higher than anticipated complaint and adverse event trend. 13671 units 2019-08-19
2012-08-22 Class II Employee error Modular necks were manufactured out of specification by a vendor; the taper provide is undersized. 70 units 2013-02-27

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer