Summit

SUMMIT FEMORAL STEM 12/14 TAPER TAPERED w/DUOFIX HA SIZE 10 STD 170mm

Registry build 21.09.26
14manufacturers in China registered for this device type
8catalogue numbers in this listing
2510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Jiangsu (8), Shanghai (2), Zhejiang (2). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MEH
Manufacturer City Province Registered as Device types
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
Lincotek (Wuxi) Co., Ltd. Wuxi Jiangsu Contract manufacturer 7
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate

Record

Regulatory record for Summit
Listed by Depuy Orthopaedics, Inc., United States
FDA product code MEH
Device type Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
Device class Class 2
Regulation 21 CFR 888.3353
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter
Record published 2015-09-24
Record revised 2024-12-13 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for Summit
Catalogue number Size Status
1570-12-165 In distribution
1570-02-135 In distribution
1570-02-080 In distribution
1570-02-110 In distribution
1570-02-180 In distribution
1570-02-120 In distribution
1570-02-100 In distribution
1570-02-090 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Alteon Exactech, Inc. 326
Novation Exactech, Inc. 317
Pinnacle Depuy Orthopaedics, Inc. 305
SP-CL Hip Stem Waldemar Link GmbH & Co. KG 219
Emperion Smith & Nephew, Inc. 201
MobileLink Acetabular Cup System Waldemar Link GmbH & Co. KG 154
Instrument Howmedica Osteonics Corp 145
Restoration Howmedica Osteonics Corp 144
Mfinity Femoral System Medacta International SA 138
Echelon Smith & Nephew, Inc. 134
Trinity Acetabular Hip System Corin Limited 128
Redapt Smith & Nephew, Inc. 127

Showing 12 of 805. All products under Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K193398 2020-02-04
K150862 2015-09-25

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2016-10-25 Class II Under Investigation by firm DePuy Orthopaedics, Inc. is issuing a voluntary recall for all lots of the ACTIS Flex Reamers due to the instruments breaking and potentially leaving pieces in the patient. 137 2017-06-06

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer