Trinity Acetabular Hip System With Hxlpe Liners

Trinity CoCr Modular Head Ø40mm SHORT -4.0mm 12/14 Eurocone Taper

Registry build 21.09.26
14manufacturers in China registered for this device type
54catalogue numbers in this listing
1510(k) clearance
14recalls on this code

Who Else Makes It

Concentrated in Jiangsu (8), Shanghai (2), Zhejiang (2). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MEH
Manufacturer City Province Registered as Device types
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
Lincotek (Wuxi) Co., Ltd. Wuxi Jiangsu Contract manufacturer 7
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate

Record

Regulatory record for Trinity Acetabular Hip System with Hxlpe Liners
Listed by Corin Limited, United Kingdom
FDA product code MEH
Device type Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
Device class Class 2
Regulation 21 CFR 888.3353
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K110087
Record published 2016-08-17
Record revised 2024-09-11 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Trinity Acetabular Hip System with Hxlpe Liners
Catalogue number Size Status
921.03.736 In distribution
921.01.346 In distribution
299.765 In distribution
921.01.928 In distribution
921.05.840 In distribution
921.141 In distribution
299.758 In distribution
299.740 In distribution
E321.040 In distribution
321.05.928 In distribution
321.05.836 In distribution
A399.110 In distribution
321.04.732 In distribution
921.05.836 In distribution
921.05.736 In distribution
299.743 In distribution
921.126 In distribution
321.04.640 In distribution
321.04.728 In distribution
299.759 In distribution
299.750 In distribution
299.744 In distribution
921.135 In distribution
299.746 In distribution
921.098 In distribution
299.763 In distribution
299.741 In distribution
E321.140 In distribution
921.05.640 In distribution
921.02.932 In distribution
321.05.936 In distribution
321.04.928 In distribution
299.760 In distribution
321.02.732 In distribution
921.04.836 In distribution
321.05.732 In distribution
321.03.636 In distribution
321.01.728 In distribution
921.028 In distribution
921.01.628 In distribution
321.04.628 In distribution
321.05.636 In distribution
321.02.832 In distribution
299.757 In distribution
321.01.828 In distribution
299.718 In distribution
321.04.836 In distribution
299.754 In distribution
921.05.940 In distribution
299.752 In distribution
299.048 In distribution
321.03.632 In distribution
921.04.740 In distribution
299.738 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Alteon Exactech, Inc. 326
Novation Exactech, Inc. 317
Pinnacle Depuy Orthopaedics, Inc. 305
SP-CL Hip Stem Waldemar Link GmbH & Co. KG 219
Emperion Smith & Nephew, Inc. 201
MobileLink Acetabular Cup System Waldemar Link GmbH & Co. KG 154
Instrument Howmedica Osteonics Corp 145
Restoration Howmedica Osteonics Corp 144
Mfinity Femoral System Medacta International SA 138
Echelon Smith & Nephew, Inc. 134
Trinity Acetabular Hip System Corin Limited 128
Redapt Smith & Nephew, Inc. 127

Showing 12 of 805. All products under Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K261576 2026-08-10

Recalls

14 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2021-07-28 Class II Storage The packaging system on the devices have potential physical and water damage resulting in damage to the devices, loss of sterility, or contamination of the devices. 5 units 2024-06-12
2021-07-28 Class II Storage The packaging system on the devices have potential physical and water damage resulting in damage to the devices, loss of sterility, or contamination of the devices. 2 2024-06-12
2021-07-28 Class II Storage The packaging system on the devices have potential physical and water damage resulting in damage to the devices, loss of sterility, or contamination of the devices. 2 units 2024-06-12
2021-07-28 Class II Storage The packaging system on the devices have potential physical and water damage resulting in damage to the devices, loss of sterility, or contamination of the devices. 4 2024-06-12
2021-07-28 Class II Storage The packaging system on the devices have potential physical and water damage resulting in damage to the devices, loss of sterility, or contamination of the devices. 5 2024-06-12
2021-07-28 Class II Storage The packaging system on the devices have potential physical and water damage resulting in damage to the devices, loss of sterility, or contamination of the devices. 2 units 2024-06-12
2021-07-28 Class II Storage The packaging system on the devices have potential physical and water damage resulting in damage to the devices, loss of sterility, or contamination of the devices. 1 unit 2024-06-12
2021-07-28 Class II Storage The packaging system on the devices have potential physical and water damage resulting in damage to the devices, loss of sterility, or contamination of the devices. 6 units 2024-06-12
2021-07-28 Class II Storage The packaging system on the devices have potential physical and water damage resulting in damage to the devices, loss of sterility, or contamination of the devices. 1 unit 2024-06-12
2021-07-28 Class II Storage The packaging system on the devices have potential physical and water damage resulting in damage to the devices, loss of sterility, or contamination of the devices. 2 units 2024-06-12
2021-05-06 Class II Under Investigation by firm Units from one batch of TriFit TS size 2 stem were found to be labeled as a TriFit CF size 7 stem. And vice versa. 1 unit 2023-07-05
2021-05-06 Class II Under Investigation by firm Units from one batch of TriFit TS size 2 stem were found to be labeled as a TriFit CF size 7 stem. And vice versa. 4 units 2023-07-05
2021-01-25 Class II Labeling mix-ups The size indicated on the labeling on the outer packaging, on the inner packaging, and on the patient stickers inside the packaging is incorrect: the Trinity Biolox Delta Ceramix Head 32XL is labeled as 36XL and vice-versa. 23 units 2022-11-23
2021-01-25 Class II Labeling mix-ups The size indicated on the labeling on the outer packaging, on the inner packaging, and on the patient stickers inside the packaging is incorrect: the Trinity Biolox Delta Ceramix Head 32XL is labeled as 36XL and vice-versa. 23 units 2022-11-23

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer