V40 Head

4 catalogue numbers from 6260-9-226, listed by Howmedica Osteonics Corp, United States, under Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate. 14 manufacturers in China are registered for this product code.

Registry build 21.09.26
14manufacturers in China registered for this device type
4catalogue numbers in this listing
19510(k) clearances naming this product code
40recalls on this code

Who Else Makes It

Concentrated in Jiangsu (8), Shanghai (2), Zhejiang (2). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MEH
Manufacturer City Province Registered as Device types
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
Lincotek (Wuxi) Co., Ltd. Wuxi Jiangsu Contract manufacturer 7
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate

Record

Regulatory record for V40 Head
Listed by Howmedica Osteonics Corp, United States
FDA product code MEH
Device type Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
Device class Class 2
Regulation 21 CFR 888.3353
Establishment Contract manufacturer, Contract steriliser, Specification developer, Manufacturer
Record published 2015-09-24
Record revised 2025-09-08 (version 6)

Specifications

Specifications
MRI safety MR Conditional
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number
Sizes Outer diameter 26 to 32 mm

Catalogue Numbers

Catalogue numbers for V40 Head
Catalogue number Size Status
6260-9-226 Offset: 4.0 Millimeter In distribution
6260-5-028 Offset: -4.0 Millimeter In distribution
6260-5-032 Offset: -4.0 Millimeter In distribution
6260-9-128 Outer Diameter 28.0 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Alteon Exactech, Inc. 326
Novation Exactech, Inc. 317
Pinnacle Depuy Orthopaedics, Inc. 305
SP-CL Hip Stem Waldemar Link GmbH & Co. KG 219
Emperion Smith & Nephew, Inc. 201
MobileLink Acetabular Cup System Waldemar Link GmbH & Co. KG 154
Instrument Howmedica Osteonics Corp 145
Restoration Howmedica Osteonics Corp 144
Mfinity Femoral System Medacta International SA 138
Echelon Smith & Nephew, Inc. 134
Trinity Acetabular Hip System Corin Limited 128
Redapt Smith & Nephew, Inc. 127

Showing 12 of 805. All products under Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K122853 2013-02-01
K112556 2011-09-28
K093644 2009-12-18
K092406 2009-11-04
K092561 2009-10-20
K091161 2009-06-16
K082892 2008-12-29
K081044 2008-06-03
K072020 2007-10-18
K032300 2003-10-09
K023102 2002-10-09
K020615 2002-05-13
K020572 2002-03-04
K013676 2001-12-05
K001448 2000-08-04
K994366 2000-03-16
K993768 2000-01-21
K993077 1999-10-08
K992025 1999-08-13

Recalls Naming This Product

1 recall names this product by its own identifier, the UDI on its label.

Recalls naming the identifiers of V40 Head
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Howmedica Osteonics Corp UDI-DI 2021-12-21 Class II Under Investigation by firm There is a potential for the outer Tyvek lid to de-bond from the sealed package. 8 units

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-07-30 Not classified Process change control Affected devices were manufactured with Ultra High Molecular Weight Polyethylene (UHMWPE) raw material aged in excess of five years. Product has the potential for elevated levels of oxidation, which may result in increased wear, leading to 12,156 US
2014-12-15 Class II Process control Five customer complaints were received for the same batch of Trident PSL Shells (part number 540-11-50E lot 49073501) alleging that when the packages were opened there were no dome holes plugs present. seven units 2016-09-22
2014-02-03 Class II Error in labeling Stryker received a report from the field indicating that a citation TMZF HA 132 degrees neck angle V40 Hip Stem – Left Size # 4
was identified in a packaging associated with a citation TMZF HA 132 degrees Neck Angle V40 Hip Stem – Right S
48 units 2014-12-02
2012-10-23 Class II Labeling mix-ups Stryker has received a report that single size 3.5 stem was packaged as size 2.5 stem resulting in a possible product mix. 6021-2530- four units; 6021-3535- 2013-09-11
2012-04-30 Class II Device Design Stryker has updated the instruction for use (IFU) (product correction)for the ABGII Modular and Rejuvenate Modular Hip Systems. This is based on a reported rate of less than one percent for revisions potentially associated with fretting an 9003 units
2012-04-30 Class II Device Design Stryker has updated the instruction for use (IFU) (product correction)for the ABGII Modular and Rejuvenate Modular Hip Systems. This is based on a reported rate of less than one percent for revisions potentially associated with fretting an (NLS/NLV) – 23193 units and (SPT) – 20,743 units
2011-10-27 Not classified Error in labeling An incorrect laser mark was noted on specific lots of product, incorrectly implying a stem size of 9, when the product is actually size 8. 31 Units 2013-08-22
2011-09-06 Not classified Packaging As part of Stryker’s quality process, a packaging discrepancy was identified in specific lots of Stryker’s Duration packaging. 39,483 units 2015-11-17
2011-07-14 Not classified Mixed-up of materials/components Stryker Orthopaedics has become aware that a size 3 Accolade stem was in a box labeled as a size 5 Accolade stem. 21 units 2013-11-15
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-01-21 Not classified Other The Restoration ADM Trial Cup Holder may not have been assembled correctly. 5 units 2012-06-20
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-01-14 Not classified Device Design Stryker Orthopaedics became aware that there may be difficulty in mating stem to implantation/extraction instrument. 786 total stems 2012-07-18
2009-01-14 Not classified Device Design Stryker Orthopaedics became aware that there may be difficulty in mating stem to implantation/extraction instrument. 786 total stems 2012-07-18
2009-01-06 Not classified Process control Product deviation : Specific lots of sprayed HA hip stems did not meet Stryker’s Internal Material Specification for tensile bond strength and crystallinity. 1,628 total stems, all varieties. 2012-06-25
2009-01-06 Not classified Process control Product deviation : Specific lots of sprayed HA hip stems did not meet Stryker’s Internal Material Specification for tensile bond strength and crystallinity. 1,628 total stems, all varieties. 2012-06-25
2009-01-06 Not classified Process control Product deviation : Specific lots of sprayed HA hip stems did not meet Stryker’s Internal Material Specification for tensile bond strength and crystallinity. 1,628 total stems, all varieties. 2012-06-25
2009-01-06 Not classified Process control Product deviation : Specific lots of sprayed HA hip stems did not meet Stryker’s Internal Material Specification for tensile bond strength and crystallinity. 1,628 total stems, all varieties. 2012-06-25

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer