Airo®
AIRO® Computed Tomography (CT) X-ray System
Who Else Makes It
Concentrated in Beijing (2), Shanghai (2), Jiangsu (2). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Philips Healthcare (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 5 |
| Qisda Electronics (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 5 |
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| GE Healthcare (China) Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shanghai, Medical Equipment Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Neusoft Medical Systems Co., Ltd. | Shenyang | Liaoning | Manufacturer | 1 |
| Philips Health Technology (China) Co., Ltd. Shenyang Branch | Shenyang | Liaoning | Specification developer | 1 |
Record
| Listed by | Mobius Imaging, LLC, United States |
|---|---|
| FDA product code | JAK |
| Device type | System, X-Ray, Tomography, Computed |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1750 |
| Establishment | Specification developer, Manufacturer |
| Record published | 2016-09-30 |
| Record revised | 2026-06-10 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
| Storage | Handling environment humidity 5 to 95 % RH; Storage environment humidity 20 to 70 % RH; Handling environment temperature 0 to 50 °C; Storage environment temperature 10 to 25 °C |
| Packaging | Crate |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| MobiCT-32 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Visicoil | IZI Medical Products LLC | 48 |
| Visicoil MR | IZI Medical Products LLC | 41 |
| Illumisite | Covidien LP | 25 |
| Imbio LDA | Imbio, LLC | 24 |
| Edge | Covidien LP | 20 |
| Revolution | GE Hangwei Medical Systems Co., Ltd. | 20 |
| Gold Fiducial | IZI Medical Products LLC | 20 |
| superDimension | Covidien LP | 17 |
| Lodox | Lodox Systems (PTY) Ltd. | 12 |
| Revolution | GE Medical Systems, L.L.C. | 12 |
| Toshiba Scanner | Canon Inc. | 10 |
| syngo.CT Dual Energy | Siemens Healthcare Limited | 7 |
Showing 12 of 495. All products under System, X-Ray, Tomography, Computed
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K180393 | 2018-03-15 |
| K160126 | 2016-04-19 |
| K131431 | 2013-09-26 |
Recalls Naming This Product
4 recalls name this product by its own identifiers, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Mobius Imaging, LLC | UDI-DI | 2025-12-04 | Class II | Labeling Change Control | AIRO pendant replacement kits and upgrade do not possess the “Safe Hand Position Warning” label. | 101 units | |
| Mobius Imaging, LLC | UDI-DI | 2025-12-04 | Class II | Labeling Change Control | AIRO pendant replacement kits and upgrade do not possess the “Safe Hand Position Warning” label. | 26 units | |
| Mobius Imaging, LLC | UDI-DI | 2022-12-07 | Class II | Use error | Stryker received one report of an injury to an untrained user that occurred while the untrained user was moving an Airo TruCT unit in reverse. The firm will increase visibility of instructions for users to consider when transporting the uni | 303 | |
| Mobius Imaging, LLC | UDI-DI | 2022-11-18 | Class II | Other | Stryker received a report of a battery fire involving an Airo TruCT unit previously subjected to bypass charging. The firm is notifying customers with units whose battery monitoring systems were bypassed to charge the batteries; the batteri | 3 | 2025-02-26 |
Recalls
4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2018-08-01 | Class II | Radiation Control for Health and Safety Act | The Tube Current Modulation feature (Modulated Scans) is not working in AIRO systems with software version 2.0.0.0, and operators would not be able to detect this fault until after a scan is completed. | 147 | 2019-12-13 |
| 2017-09-26 | Class II | Under Investigation by firm | If the tilt-drive motor has an intermittent connection or broken encoder or sensor wire there is a risk of unintended or unpredictable device motion while the CT system is homing the axis at startup or preparing for a scan. | 105 | 2018-08-16 |
| 2017-07-28 | Class II | Component design/selection | Risk of unintended motion while the AIRO system is in transport mode. | 102 | 2018-07-25 |
| 2014-12-08 | Class II | Software design | There is a risk that during the transfer of an image and navigation data to the Brainlab Curve Image Guided Surgery Navigation System after a CT scan, an error may occur, causing either no navigation data or incorrect navigation data being | 21 devices distributed. 15 of these devices affected by the | 2015-07-06 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.