Brivo 615
TANDEM GANTRY-B615 Medical Device
Who Else Makes It
Concentrated in Beijing (2), Shanghai (2), Jiangsu (2). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Philips Healthcare (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 5 |
| Qisda Electronics (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 5 |
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| GE Healthcare (China) Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shanghai, Medical Equipment Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Neusoft Medical Systems Co., Ltd. | Shenyang | Liaoning | Manufacturer | 1 |
| Philips Health Technology (China) Co., Ltd. Shenyang Branch | Shenyang | Liaoning | Specification developer | 1 |
Record
| Listed by | Ge Hualun Medical Systems Co., Ltd., China |
|---|---|
| FDA product code | JAK |
| Device type | System, X-Ray, Tomography, Computed |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1750 |
| 510(k) | K113350 |
| Record published | 2016-05-13 |
| Record revised | 2025-04-07 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 5376496-15 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Visicoil | IZI Medical Products LLC | 48 |
| Visicoil MR | IZI Medical Products LLC | 41 |
| Illumisite | Covidien LP | 25 |
| Imbio LDA | Imbio, LLC | 24 |
| Edge | Covidien LP | 20 |
| Revolution | GE Hangwei Medical Systems Co., Ltd. | 20 |
| Gold Fiducial | IZI Medical Products LLC | 20 |
| superDimension | Covidien LP | 17 |
| Lodox | Lodox Systems (PTY) Ltd. | 12 |
| Revolution | GE Medical Systems, L.L.C. | 12 |
| Toshiba Scanner | Canon Inc. | 10 |
| syngo.CT Dual Energy | Siemens Healthcare Limited | 7 |
Showing 12 of 495. All products under System, X-Ray, Tomography, Computed
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| GE Medical Systems Israel, Functional Imaging | 510(k) number | 2024-12-18 | Class II | Package design/selection | GE HealthCare has become aware that certain Infinia, VariCam/VG/VH, Brivo NM 615, Discovery NM 630, Discovery NM/CT 670, and Optima NM/CT 640 Nuclear Medicine systems (see Affected Products Details and Appendices) could have been transporte | 116 units | |
| GE Medical Systems Israel, Functional Imaging | 510(k) number | 2022-12-19 | Class I | Process control | A mitigation may not be correctly implemented. If this is the case, the detector can fall, leading to life-threatening bodily injury. | 7 units | |
| GE Medical Systems, LLC | 510(k) number | 2013-10-25 | Class II | Employee error | GE Healthcare has recently become aware of a potential safety issue related to a SPECT scan procedure used for pulmonary imaging. Contact between the Detector (GE Healthcare Discovery NM/CT 670, and/or Optima NM/CT 640, and/or Discovery | 464 (143 US, 321 OUS) | 2014-04-01 |
| GE Medical Systems, LLC | 510(k) number | 2013-06-13 | Class I | Device Design | GE became aware of an incident at a VA Medical Center facility in the US in which a patient died due to injuries sustained while being scanned on an Infinia Hawkeye 4 Nuclear Medicine System. UPDATE: On July 03, 2013 GE notified hospitals | 13 | 2014-06-19 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability.
Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.