Epione
EPIONE v1.0.2 is a user-controlled stereotactic accessory that assists with planning and manual advancement of instruments and verifying instrument position during CT-guided percutaneous…
EPIONE v1.0.2 is a user-controlled stereotactic accessory that assists with planning and manual advancement of instruments and verifying instrument position during CT-guided percutaneous procedures. The filing describes planning relative to target anatomy and later comparison of achieved placement with the plan.
During guidance, the system monitors respiratory levels and verifies patient position before instrument advancement. It is indicated for rigid straight instruments, including needles, cryoprobes, electrodes and antennas, in CT-guided procedures on abdominal organs and structures performed by physicians trained for CT procedures.
Listed Item
The EPIONE device is a user controlled, stereotactic accessory intended to assist in the planning and manual advancement of one more instruments, as well as in verification of instrument position during Computed Tomography (CT) guided percutaneous procedures.
Procedure Phases
The filing describes planning the desired instrument placement, guiding advancement while monitoring respiration and position, and assessing placement against the original plan using pre- and post-treatment image overlays. It identifies EPIONE version 1.0.2 as a modified version of the previously cleared device.
Who Else Makes It
Concentrated in Beijing (2), Shanghai (2), Jiangsu (2). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Philips Healthcare (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 5 |
| Qisda Electronics (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 5 |
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| GE Healthcare (China) Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shanghai, Medical Equipment Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Neusoft Medical Systems Co., Ltd. | Shenyang | Liaoning | Manufacturer | 1 |
| Philips Health Technology (China) Co., Ltd. Shenyang Branch | Shenyang | Liaoning | Specification developer | 1 |
Record
| Listed by | Quantum Surgical SAS, France |
|---|---|
| FDA product code | JAK |
| Device type | System, X-Ray, Tomography, Computed |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1750 |
| Establishment | Manufacturer |
| 510(k) | K223758 |
| Record published | 2023-05-25 |
| Record revised | 2026-03-19 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 30-0001 v1.0.2 | In distribution | |
| 30-0001 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Visicoil | IZI Medical Products LLC | 48 |
| Visicoil MR | IZI Medical Products LLC | 41 |
| Illumisite | Covidien LP | 25 |
| Imbio LDA | Imbio, LLC | 24 |
| Edge | Covidien LP | 20 |
| Revolution | GE Hangwei Medical Systems Co., Ltd. | 20 |
| Gold Fiducial | IZI Medical Products LLC | 20 |
| superDimension | Covidien LP | 17 |
| Lodox | Lodox Systems (PTY) Ltd. | 12 |
| Revolution | GE Medical Systems, L.L.C. | 12 |
| Toshiba Scanner | Canon Inc. | 10 |
| syngo.CT Dual Energy | Siemens Healthcare Limited | 7 |
Showing 12 of 495. All products under System, X-Ray, Tomography, Computed
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K223758 | 2023-05-03 |
| K211645 | 2022-02-24 |
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Quantum Surgical SAS | 510(k) number | 2025-05-23 | Class II | Under Investigation by firm | Due to a software bug the robotic arm may incorrectly guide the instrument compared to the planning defined by user. | 4 units in U.S. |
| Quantum Surgical SAS | 510(k) number | 2024-08-05 | Class II | Under Investigation by firm | Quantum Surgical has become aware that a component (central axis) inside the Needle Guide product (product number 02-0027) is the subject of rust. | 2 units |