MAR

MAR Application Container for Smart Subscription

Registry build 21.09.26
8manufacturers in China registered for this device type
2catalogue numbers in this listing
8510(k) clearances naming this product code
4recalls on this code

Who Else Makes It

Concentrated in Beijing (2), Shanghai (2), Jiangsu (2). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JAK
Manufacturer City Province Registered as Device types
Philips Healthcare (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 5
Qisda Electronics (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 5
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
GE Healthcare (China) Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shanghai, Medical Equipment Ltd. Shanghai Shanghai Contract manufacturer 10
Neusoft Medical Systems Co., Ltd. Shenyang Liaoning Manufacturer 1
Philips Health Technology (China) Co., Ltd. Shenyang Branch Shenyang Liaoning Specification developer 1

Record

Regulatory record for MAR
Listed by GE Healthcare Japan Corporation, Japan
FDA product code JAK
Device type System, X-Ray, Tomography, Computed
Device class Class 2
Regulation 21 CFR 892.1750
Establishment Specification developer, Manufacturer
510(k) K132410
Record published 2017-10-25
Record revised 2026-01-30 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Prescription Prescription only
Label carries lot or batch number, manufacturing date

Catalogue Numbers

Catalogue numbers for MAR
Catalogue number Size Status
1.0 In distribution
1.1 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Visicoil IZI Medical Products LLC 48
Visicoil MR IZI Medical Products LLC 41
Illumisite Covidien LP 25
Imbio LDA Imbio, LLC 24
Edge Covidien LP 20
Revolution GE Hangwei Medical Systems Co., Ltd. 20
Gold Fiducial IZI Medical Products LLC 20
superDimension Covidien LP 17
Lodox Lodox Systems (PTY) Ltd. 12
Revolution GE Medical Systems, L.L.C. 12
Toshiba Scanner Canon Inc. 10
syngo.CT Dual Energy Siemens Healthcare Limited 7

Showing 12 of 495. All products under System, X-Ray, Tomography, Computed

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K253686 2026-03-23
K233698 2024-04-11
K230807 2023-04-20
K220961 2022-07-29
K213938 2022-02-04
K212067 2021-09-17
K203169 2020-11-20
K193170 2019-12-13

Recalls Naming This Product

2 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of MAR
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
GE Medical Systems, LLC 510(k) number 2018-05-24 Class II Component change control Some CT and CT/PET systems recently installed with a GE supplied A! electrical panel may not be properly wired to the partial system UPS (Uninteruptible Power Supply). 42 units total 2019-02-08
GE Medical Systems, LLC 510(k) number 2017-05-19 Class II Software design It was discovered that an issue has been identified that can result in a scan starting before the prescribed delay has completed. 10,884 2018-07-29

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2018-04-27 Class II Employee error GE Healthcare has identified that some CT systems may have a damaged cable that can expose 120VAC to Service Engineers working inside the gantry. 4,007 devices total (products 1, 2, 3) 2020-08-21
2018-04-27 Class II Employee error GE Healthcare has identified that some CT systems may have a damaged cable that can expose 120VAC to
Service Engineers working inside the gantry.
4,007 devices total (products 1, 2, 3) 2020-08-21
2018-04-27 Class II Employee error GE Healthcare has identified that some CT systems may have a damaged cable that can expose 120VAC to
Service Engineers working inside the gantry.
92 OUS only 2020-08-21
2018-04-27 Class II Employee error GE Healthcare has identified that some CT systems may have a damaged cable that can expose 120VAC to
Service Engineers working inside the gantry.
4,007 devices total (products 1, 2, 3) 2020-08-21

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer