MiniCAT

The FDA filing identifies MiniCAT as an X-ray imaging device that constructs a three-dimensional model of the head and neck from a rotational X-ray sequence. The device is optimized for…

Registry build 21.09.26

The FDA filing identifies MiniCAT as an X-ray imaging device that constructs a three-dimensional model of the head and neck from a rotational X-ray sequence.

The device is optimized for imaging the maxillofacial complex, temporal bone, sinuses, and neuro-angiography.

Device Description and Stated Use

The filing describes a 360-degree X-ray image acquisition sequence and software for image acquisition, processing, and viewing. Major hardware components include the X-ray source, scanning arm, and detector.

8manufacturers in China registered for this device type
1catalogue number
3510(k) clearances naming this product code
10recalls on this code

Who Else Makes It

Concentrated in Beijing (2), Shanghai (2), Jiangsu (2). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JAK
Manufacturer City Province Registered as Device types
Philips Healthcare (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 5
Qisda Electronics (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 5
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
GE Healthcare (China) Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shanghai, Medical Equipment Ltd. Shanghai Shanghai Contract manufacturer 10
Neusoft Medical Systems Co., Ltd. Shenyang Liaoning Manufacturer 1
Philips Health Technology (China) Co., Ltd. Shenyang Branch Shenyang Liaoning Specification developer 1

Record

Regulatory record for MiniCAT
Listed by Xoran Technologies, LLC, United States
FDA product code JAK
Device type System, X-Ray, Tomography, Computed
Device class Class 2
Regulation 21 CFR 892.1750
Establishment Remanufacturer, Complaint-file establishment, Manufacturer
510(k) K113421
Record published 2016-09-20
Record revised 2018-07-06 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for MiniCAT
Catalogue number Size Status
10004 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Visicoil IZI Medical Products LLC 48
Visicoil MR IZI Medical Products LLC 41
Illumisite Covidien LP 25
Imbio LDA Imbio, LLC 24
Edge Covidien LP 20
Revolution GE Hangwei Medical Systems Co., Ltd. 20
Gold Fiducial IZI Medical Products LLC 20
superDimension Covidien LP 17
Lodox Lodox Systems (PTY) Ltd. 12
Revolution GE Medical Systems, L.L.C. 12
Toshiba Scanner Canon Inc. 10
syngo.CT Dual Energy Siemens Healthcare Limited 7

Showing 12 of 495. All products under System, X-Ray, Tomography, Computed

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K113421 2012-07-11
K061834 2006-08-07
K032243 2003-10-02

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of MiniCAT
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Xoran Technologies, LLC 510(k) number 2014-09-08 Class II Radiation Control for Health and Safety Act Out of tolerance kVp, Unexposed (black) frames, and Out of tolerance Dose. 432 2016-02-02

Recalls

6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2010-07-27 Class II Radiation Control for Health and Safety Act The MiniCAT CT Scanners subject to this notification failed to meet Xoran’s specifications for dose rate of 125 3 kVp. These 18 complaints received include dose rates both on the high and low end of Xoran’s specifications. See ATTACHMENT 1 2014-09-11
2010-07-27 Class II Radiation Control for Health and Safety Act A description of the defect in the product or the manner in which the product fails to comply with an applicable Federal standard; The MiniCAT CT Scanners subject to this notification failed to meet Xoran’s specifications for dose rate of 1 320 2014-09-11
2010-07-27 Class II Radiation Control for Health and Safety Act A description of the defect in the product or the manner in which the product fails to comply wvith an applicable Federal standard; The MiniCAT CT Scanners subject to this notification failed to meet Xoran’s specifications for dose rate of 320 2014-09-11
2010-07-27 Class II Radiation Control for Health and Safety Act The MiniCAT CT Scanners subject to this notification failed to meet Xoran’s specifications for dose rate of 125 3 kVp. These 18 complaints received include dose rates both on the high and low end of Xorans specifications. 320 2014-09-11
2010-07-27 Class II Radiation Control for Health and Safety Act The MiniCAT CT Scanners subject to this notification failed to meet Xoran’s specifications for dose rate of 125 3 kVp. These 18 complaints received include dose rates both on the high and low end of Xoran’s specifications. See ATTACHMENT 1 320 2014-09-11
2009-12-14 Class II Radiation Control for Health and Safety Act Failure of the gantry to rotate. The complaint alleged that the scanner would emit radiation but would not rotate. 320 2014-09-11
2008-09-17 Not classified Device Design The system may overheat, causing poor image quality, interruption in image acquisition and/or damage to the system. Also, if the system is not allowed to cycle down prior to being restarted after an emergency stop, the x-ray and gantry mot 82 2009-12-23
2008-01-04 Not classified Labeling design Misbranding; These devices do not bear the manufacturer’s name or address. 71 2010-10-22
2006-07-13 Not classified Finished device change control The hard drive may crash, resulting in loss of data from patient CT scans. 5 2008-03-13

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer