Medic Vision’s SafeCT-29 provides a vendor-neutral Radiation Dose Check functionality, in accordance with the Dose Check feature that is specified by the NEMA XR-25 Standard. The device is…
Medic Vision’s SafeCT-29 provides a vendor-neutral Radiation Dose Check functionality, in accordance with the Dose Check feature that is specified by the NEMA XR-25 Standard. The device is a software and hardware system which includes Computer, dedicated display and controls. The SafeCT-29 is interfaced to CT scanners that are not equipped with the Dose Check function. The device is connected to the CT Console video output via a standard video connector. The SafeCT-29 Computer’s internal video splitter captures the CT Console display video, in real time, without affecting neither the CT console itself nor its display. This analog video signal is digitized by a video grabber. The SafeCT-29 software analyzes the digital input video using OCR software continuously. The radiation dose information as calculated by the scanner and displayed to the CT operator is extracted and analyzed in real time. The SafeCT- 29 captures the video of the CT Console display in real time, without affecting neither the CT console itself nor its display and workflow. As specified by NEMA XR-25 Standard, the safeCT-29 notifies and alerts the CT operators, prior to a scan, if the estimated dose index is above the predefined values set by the operating group, practice, or organization. SafeCT-29 prevents continuing an over-the-limit scan unless dose levels are reconfirmed by the operator, in accordance with NEMA XR-29*.The device records the details of such events, including the operator details and decisions. This record is available to the user.
Who Else Makes It
Concentrated in Beijing (2), Shanghai (2), Jiangsu (2). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
Record
Regulatory record for SafeCT-29 | Listed by | Medic Vision – Imaging Solutions, Ltd., Israel |
| FDA product code | JAK |
| Device type | System, X-Ray, Tomography, Computed |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1750 |
| 510(k) | K153331 |
| Record published | 2018-02-01 |
| Record revised | 2018-07-06 (version 3) |
Specifications
Specifications | MRI safety | Labeling does not contain MRI Safety Information |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | manufacturing date, serial number |
| UDI direct marking | Exempt |