Somatom Emotion 6-Slice Configuration

Catalogue number 10165888, listed by Siemens Shanghai, Medical Equipment Ltd., China, under System, X-Ray, Tomography, Computed. 8 manufacturers in China are registered for this product code.

Registry build 21.09.26
8manufacturers in China registered for this device type
1catalogue number

Who Else Makes It

Concentrated in Beijing (2), Shanghai (2), Jiangsu (2). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JAK
Manufacturer City Province Registered as Device types
Philips Healthcare (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 5
Qisda Electronics (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 5
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
GE Healthcare (China) Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shanghai, Medical Equipment Ltd. Shanghai Shanghai Contract manufacturer 10
Neusoft Medical Systems Co., Ltd. Shenyang Liaoning Manufacturer 1
Philips Health Technology (China) Co., Ltd. Shenyang Branch Shenyang Liaoning Specification developer 1

Record

Regulatory record for Somatom Emotion 6-slice configuration
Listed by Siemens Shanghai, Medical Equipment Ltd., China
FDA product code JAK
Device type System, X-Ray, Tomography, Computed
Device class Class 2
Regulation 21 CFR 892.1750
Establishment Contract manufacturer, Complaint-file establishment, Manufacturer
510(k) K133424
Record published 2016-09-24
Record revised 2021-11-17 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries serial number
Storage Handling environment atmospheric pressure 50 to 106 KiloPascal; Storage environment atmospheric pressure 50 to 106 KiloPascal; Storage environment temperature -20 to 50 °C; Storage environment humidity 10 to 95 % RH; Handling environment humidity 10 to 95 % RH; Handling environment temperature -20 to 50 °C
Distribution end date 2016-10-28

Catalogue Numbers

Catalogue numbers for Somatom Emotion 6-slice configuration
Catalogue number Size Status
10165888 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Visicoil IZI Medical Products LLC 48
Visicoil MR IZI Medical Products LLC 41
Illumisite Covidien LP 25
Imbio LDA Imbio, LLC 24
Edge Covidien LP 20
Revolution GE Hangwei Medical Systems Co., Ltd. 20
Gold Fiducial IZI Medical Products LLC 20
superDimension Covidien LP 17
Lodox Lodox Systems (PTY) Ltd. 12
Revolution GE Medical Systems, L.L.C. 12
Toshiba Scanner Canon Inc. 10
syngo.CT Dual Energy Siemens Healthcare Limited 7

Showing 12 of 495. All products under System, X-Ray, Tomography, Computed

Recalls Naming This Product

5 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Somatom Emotion 6-slice configuration
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Siemens Medical Solutions USA, Inc. 510(k) number 2016-02-15 Class II Device Design Siemens is initiating this recall due to a potential malfunction and hence potential hazard to patients and personnel when using the SOMATOM Emotion or SOMATOM Sensation systems in conjunction with the use of the cardio licenses “Cardio Pro 124 units 2016-12-07
Siemens Medical Solutions USA, Inc. 510(k) number 2015-06-04 Class II Device Design A potential safety issue involving two (2) broken screws and one (1) bowed, which is used to fix the Balance Weight of the DMS in the gantry, was found during a service call at the customer site. 40 total 2017-03-24
Siemens Medical Solutions USA, Inc. 510(k) number 2015-06-04 Class II Device Design A potential safety issue involving two (2) broken screws and one (1) bowed, which is used to fix the Balance Weight of the DMS in the gantry, was found during a service call at the customer site. 40 total 2017-03-24
Siemens Medical Solutions USA, Inc. 510(k) number 2015-04-20 Class II Software design Software bugs in VC20B SP0a or SP1 software versions may cause issues that could make it necessary to rescan patients. Syngo Main UI may crash if the Patient Browser is scrolled with arrow keys of the keyboard. Tomo images may freeze on t 75 2016-09-01
Siemens Medical Solutions USA, Inc. 510(k) number 2015-04-20 Class II Software design Software bugs in VC20B SP0a or SP1 software versions may cause issues that could make it necessary to rescan patients. Syngo Main UI may crash if the Patient Browser is scrolled with arrow keys of the keyboard. Tomo images may freeze on t 75 2016-09-01

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer