Vitrea
Vitrea® is a medical diagnostic system that allows the processing, review, analysis, communication and media interchange of digital images acquired from a variety of imaging devices. Vitrea…
Vitrea® is a medical diagnostic system that allows the processing, review, analysis, communication and media interchange of digital images acquired from a variety of imaging devices. Vitrea is not meant for primary image interpretation in mammography. Vitrea provides visualization of digital images to aid clinicians in their analysis of anatomy and pathology. The Vitrea user interface follows typical clinical workflow patterns to process, review, and analyze digital images. It is a web-based imaging system that allows physicians to use PCs or notebook computers to remotely access to 2D and 3D advanced visualization using a Microsoft web-enabled browser. Vitrea modules include automated and semi-automated visualization and advanced quantification tools targeted for a specific study based on a protocol selected by the user. The automation is only intended to reduce the manual steps required by the user to analyze and quantify the data from the images; it is not intended to detect pathology or disease. The software provides imaging information as an assist to the physician.
Who Else Makes It
Concentrated in Beijing (2), Shanghai (2), Jiangsu (2). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Philips Healthcare (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 5 |
| Qisda Electronics (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 5 |
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| GE Healthcare (China) Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shanghai, Medical Equipment Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Neusoft Medical Systems Co., Ltd. | Shenyang | Liaoning | Manufacturer | 1 |
| Philips Health Technology (China) Co., Ltd. Shenyang Branch | Shenyang | Liaoning | Specification developer | 1 |
Record
| Listed by | Canon Medical Informatics, Inc., United States |
|---|---|
| FDA product code | JAK |
| Device type | System, X-Ray, Tomography, Computed |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1750 |
| Establishment | Repacker / relabeller, Manufacturer, Exporter |
| 510(k) | K032748 |
| Record published | 2016-12-22 |
| Record revised | 2023-10-18 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | lot or batch number, manufacturing date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 7.3.2 | In distribution | |
| 7.3.1 | In distribution | |
| 6.9.2 | In distribution | |
| 6.9 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Visicoil | IZI Medical Products LLC | 48 |
| Visicoil MR | IZI Medical Products LLC | 41 |
| Illumisite | Covidien LP | 25 |
| Imbio LDA | Imbio, LLC | 24 |
| Edge | Covidien LP | 20 |
| Revolution | GE Hangwei Medical Systems Co., Ltd. | 20 |
| Gold Fiducial | IZI Medical Products LLC | 20 |
| superDimension | Covidien LP | 17 |
| Lodox | Lodox Systems (PTY) Ltd. | 12 |
| Revolution | GE Medical Systems, L.L.C. | 12 |
| Toshiba Scanner | Canon Inc. | 10 |
| syngo.CT Dual Energy | Siemens Healthcare Limited | 7 |
Showing 12 of 495. All products under System, X-Ray, Tomography, Computed
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K252217 | 2025-11-28 |
| K243240 | 2025-04-10 |
| K223261 | 2023-07-13 |
Recalls Naming This Product
8 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Canon Medical Informatics, Inc. | 510(k) number | 2013-10-21 | Class II | Software design | Vital Images, Inc. has found an issue in VitreaCore software though internal testing. There is a potential for incorrect and possibly reversed image orientation for certain snapshots taken in VitreaCore software versions 6.0, 6.1, 6.2, 6.3 | 598 | 2015-01-16 |
| Canon Medical Informatics, Inc. | 510(k) number | 2013-03-15 | Class II | Software design | Vital Images has made a decision to perform a field correction to the Vitrea CT Multi-Chamber Cardiac Functional Analysis application. Vital Images has identified a defect in which numerical values may be incorrect in the Results Table unde | 102 | 2015-02-27 |
| Canon Medical Informatics, Inc. | 510(k) number | 2013-03-15 | Class II | Labeling design | Vital Images, Inc. (Vital Images) received one report about potential user confusion when viewing a brain perfusion scan on Vitrea CT Brain Perfusion 2D when the scan was performed using a wide coverage shuttle acquisition technique. This | 1,978 | 2015-04-08 |
| Canon Medical Informatics, Inc. | 510(k) number | 2012-08-13 | Class II | Software design | Vital Images has found two potential errors in calcium score values in restored snapshots of studies generated through use of Vitrea or Vitrea Enterprise Suite. This issue affects Version 3.1 of Vitrea fX; Version 5.2 of Vitrea; Versions 6 | 2088 (1133 USA) | 2015-03-25 |
| Canon Medical Informatics, Inc. | 510(k) number | 2011-11-11 | Not classified | Software design | Vital Images has found two issues that may display incorrect Standard Update Values (SUV) when viewing certain PET/CT images. This issue affects the VitreaCore PET/CT feature for Vitrea Enterprise Suite 1.2, 1.3, 6.0, 6.1, including all up | 338 (233 US) | 2013-12-03 |
| Canon Medical Informatics, Inc. | 510(k) number | 2010-10-14 | Not classified | Software design | Vital Images Inc., reported that a software defect exists with Vitrea fX 2.1, 3.0 and 3.1 CT Brain Analysis whereby the annotated numeric ROI values on a batched perfusion map are incorrect when created using the auto batching function (fro | 182 | 2012-05-15 |
| Canon Medical Informatics, Inc. | 510(k) number | 2010-08-23 | Not classified | Software design | There is a potential alignment error of fused PET/CT images in the Vitrea Core component of Vitrea Enterprise Suite 1.2 and 1.3. The error occurs during panning of the fused PET/CT images. Because the PET data has a larger voxel size than | 178 | 2012-11-06 |
| Canon Medical Informatics, Inc. | 510(k) number | 2007-11-08 | Not classified | Process control | Standard Uptake Values (SUV) display/update problems; in the way Standard Uptake Values (SUV) are displayed in 3D/MPR views. The problem arises when a user draws a selected region of interest in order to calculate the SUV statistics of the | 18 | 2011-12-17 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.