O-armTM O2 Imaging System

O-ARM SYS BI70002000 O2 UE 120V B EN UEN

Registry build 21.09.26
3manufacturers in China registered for this device type
1catalogue number

Who Else Makes It

Concentrated in Beijing (2), Shanghai (1).

Chinese manufacturers registered for FDA product code OXO
Manufacturer City Province Registered as Device types
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
GE Healthcare (China) Co., Ltd. Beijing Beijing Specification developer 22
Siemens Shanghai, Medical Equipment Ltd. Shanghai Shanghai Contract manufacturer 10

Record

Regulatory record for O-armTM O2 Imaging System
Listed by Medtronic Navigation, Inc., United States
FDA product code OXO
Device type Image-Intensified Fluoroscopic X-Ray System, Mobile
Device class Class 2
Regulation 21 CFR 892.1650
Establishment Specification developer, Repacker / relabeller, Manufacturer
510(k) K240465
Record published 2024-08-26

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries serial number
Storage Storage environment temperature -10 to 40 °C; Storage environment humidity 10 to 80 % RH
Sizes Weight 1087 kg

Catalogue Numbers

Catalogue numbers for O-armTM O2 Imaging System
Catalogue number Size Status
BI70002000 Weight 1087.0 kg In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
O-ARM® Medtronic Navigation, Inc. 16
Cios Select Siemens Shanghai, Medical Equipment Ltd. 3
Smart-C Turner Imaging Systems, Inc. 3
Zenition Philips Medical Systems Nederland B.V. 2
Broach Set SPX1 Ecential Robotics 2
Image-Intensified Fluoroscopic X-Ray System, Mobile Ecotron Co., Ltd. 2
Flourocsan InSight Hologic, Inc. 2
Genoray Genoray Co., Ltd. 2
3D Imaging Set SPX1 Ecential Robotics 2
Discovery GE Medical Systems, LLC 2
OEC Ge Hualun Medical Systems Co., Ltd. 2
Cios Alpha Siemens Healthcare Limited 1

Showing 12 of 40. All products under Image-Intensified Fluoroscopic X-Ray System, Mobile

Recalls Naming This Product

2 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of O-armTM O2 Imaging System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Medtronic Navigation, Inc. (Boxborough) 510(k) number 2026-05-19 Class II Under Investigation by firm Potential for image artifacts caused by an anomaly in the O-arm O2 Imaging System s detector panel firmware. 589 units
Medtronic Navigation, Inc. (Boxborough) 510(k) number 2025-05-27 Class II Under Investigation by firm A mechanical component that supports the O2 gantry to the support structure in affected devices may have been damaged during manufacture. 3 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer