Catalyst+ PT

Catalyst+ PT is an optical surface imaging system used in radiation therapy clinics to guide patient positioning, monitor movement during treatment, and support respiratory gating. It…

Registry build 21.09.26

Catalyst+ PT is an optical surface imaging system used in radiation therapy clinics to guide patient positioning, monitor movement during treatment, and support respiratory gating. It combines projector hardware with software that compares the patient’s current surface with a reference image.

The system calculates couch corrections and posture differences. Colored light can project guidance onto the patient, while motion monitoring can issue a warning or interrupt the treatment beam when movement exceeds defined tolerances.

Clinical Integration

The PT configuration can use additional scanning units for patient coverage. Respiratory gating follows the treatment plan’s parameters. The system requires qualified radiation therapy personnel and is not intended for MR-linac systems.

8manufacturers in China registered for this device type
1catalogue number
6510(k) clearances naming this product code
3recalls on this code

Who Else Makes It

Concentrated in Guangdong (2), Jiangsu (2), Beijing (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code IYE
Manufacturer City Province Registered as Device types
Guangzhou Tian Hong Medical Technology Co., Ltd. Guangzhou Guangdong Contract manufacturer 4
Klarity Medical & Equipment (GZ) Co., Ltd. Guangzhou Guangdong Contract manufacturer 3
Elekta Beijing Medical Systems Co., Ltd. Beijing Beijing Contract manufacturer 1
Manteia Technologies Co., Ltd. Xiamen Fujian Manufacturer 3
OUR United Corporation Xian Shaanxi Contract manufacturer 2
Suzhou Linatech Medical Science AND Technology Co., Ltd. Suzhou Jiangsu Manufacturer 2
Varian Medical Systems China Co., Ltd. Beijing Beijing Manufacturer 2
Jiangsu Rayer Medical Technology Co., Ltd. Wuxi Jiangsu Manufacturer 1

Record

Regulatory record for Catalyst+ PT
Listed by C-RAD Positioning AB, Sweden
FDA product code IYE
Device type Accelerator, Linear, Medical
Device class Class 2
Regulation 21 CFR 892.5050
Establishment Manufacturer
510(k) K200435
Record published 2024-08-06

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Catalyst+ PT
Catalogue number Size Status
SP003-0008 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Klarity Medical Klarity Medical Products, LLC 891
Orfit Industries Orfit Industries NV 680
Aquaplast RT™ Qfix 569
Fibreplast® Qfix 271
Bionix Radiation Therapy Bionix Radiation Therapy, LLC 115
Vac-Lok™ Cushion Medtec LLC 100
Visicoil IZI Medical Products LLC 86
BodyFIX 3C-Medical Intelligence GmbH 84
AlignRT Plus Vision RT Limited 72
Fibreplast® Assure™ Open View Qfix 72
Accelerator, Linear, Medical PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH 71
Thermoplastic Mask IZI Medical Products LLC 58

Showing 12 of 1,611. All products under Accelerator, Linear, Medical

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K200435 2020-05-07
K200600 2020-04-20
K120668 2012-07-30
K113276 2012-02-27
K082582 2009-03-30
K063839 2007-02-08

Recalls Naming This Product

2 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Catalyst+ PT
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
C-RAD Positioning AB 510(k) number 2025-10-09 Class II Under Investigation by firm Due to issues with the system’s stereotactic radiosurgery (SRS) treatment cannot be guaranteed for all couch angles and system setups. n certain cases, the system may indicate the patient as correctly positioned at the isocenter, even when 189
C-RAD Positioning AB 510(k) number 2025-04-22 Class II Software design Software issue with scanning equipment that can results in the filed rotation not being applied correctly. 44 units

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2020-08-06 Class II Component change control PC Application Software c4D not changing Site upon synchronization during the Setup workflow step 7 2022-04-15

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer