Cranial 4PI Head Support Wide

Catalogue number 43460, listed by Brainlab SE, Germany, under Accelerator, Linear, Medical. 8 manufacturers in China are registered for this product code.

Registry build 21.09.26
8manufacturers in China registered for this device type
1catalogue number
1510(k) clearance
17recalls on this code

Who Else Makes It

Concentrated in Guangdong (2), Jiangsu (2), Beijing (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code IYE
Manufacturer City Province Registered as Device types
Guangzhou Tian Hong Medical Technology Co., Ltd. Guangzhou Guangdong Contract manufacturer 4
Klarity Medical & Equipment (GZ) Co., Ltd. Guangzhou Guangdong Contract manufacturer 3
Elekta Beijing Medical Systems Co., Ltd. Beijing Beijing Contract manufacturer 1
Manteia Technologies Co., Ltd. Xiamen Fujian Manufacturer 3
OUR United Corporation Xian Shaanxi Contract manufacturer 2
Suzhou Linatech Medical Science AND Technology Co., Ltd. Suzhou Jiangsu Manufacturer 2
Varian Medical Systems China Co., Ltd. Beijing Beijing Manufacturer 2
Jiangsu Rayer Medical Technology Co., Ltd. Wuxi Jiangsu Manufacturer 1

Record

Regulatory record for Cranial 4PI Head Support Wide
Listed by Brainlab SE, Germany
FDA product code IYE
Device type Accelerator, Linear, Medical
Device class Class 2
Regulation 21 CFR 892.5050
Establishment Manufacturer, Exporter
510(k) K243142
Record published 2025-06-26
Record revised 2025-09-17 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries serial number

Catalogue Numbers

Catalogue numbers for Cranial 4PI Head Support Wide
Catalogue number Size Status
43460 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Klarity Medical Klarity Medical Products, LLC 891
Orfit Industries Orfit Industries NV 680
Aquaplast RT™ Qfix 569
Fibreplast® Qfix 271
Bionix Radiation Therapy Bionix Radiation Therapy, LLC 115
Vac-Lok™ Cushion Medtec LLC 100
Visicoil IZI Medical Products LLC 86
BodyFIX 3C-Medical Intelligence GmbH 84
AlignRT Plus Vision RT Limited 72
Fibreplast® Assure™ Open View Qfix 72
Accelerator, Linear, Medical PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH 71
Thermoplastic Mask IZI Medical Products LLC 58

Showing 12 of 1,611. All products under Accelerator, Linear, Medical

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K254010 2026-01-14

Recalls

13 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2023-02-14 Class II Software design Deep Inspiration Breath Hold (DIBH) functionality may not work as specified when based on a standard-workflow Treatment Template 56 systems in the U.S.
2022-02-25 Class II Software design The yaw angle may be incorrect for CBCT positioning workflows using setup beams with Varian LINACs. 205 systems
2021-05-14 Class II Software design Display of potential patient movement might be delayed to the user for high dose treatments. 22 systems in the U.S. 2023-03-20
2021-03-01 Class II Software design In case of a failed automatic marker detection, a software error causes parts of the
display to incorrectly behave as if the current patient position is within predefined tolerances
and may allow the user to proceed to treatment despite pot
73 ExacTrac Dynamic systems (versions 1.0.0, 1.0.1, 1.0.2) h 2023-03-20
2018-02-14 Class II Other The usage of workflows that deviate from the recommended specifications in the User manual for ExacTrac Patient Positioning System (versions 6.0, 6.1, 6.2, 6.5) with Auxiliary Device Interface (ADI) and Varian Clinac or Varian TrueBeam, whi 587 systems 2021-05-17
2017-11-03 Class II Software design Brainlab has internally detected that under specific conditions ExacTrac Vero may not correctly account for this ring angle correction during the calculation of the corresponding couch shift. This may result in the treatment couch not movi 28 units 2020-12-14
2016-05-04 Class II Device Design Potentially incorrect positioning when using Implanted Marker Detection with Brainlab ExacTrac Vero 3.5 27 Systems 2017-07-24
2015-08-05 Class II Software in the Use Environment ExacTrac 6.0 Patient Positioning System:
Display of potentially incorrect Digitally Reconstructed Radiograph (DRR) for x-ray correction and
verification.
361 systems 2017-01-05
2015-02-16 Class II Software in the Use Environment The ExacTrac 6.x Patient Positioning System may incorrectly position the patient when using the ExacTrac Cone Beam CT (CBCT) with a TrueBeam-specific optional subvolume-CBCT. 24 systems (US); 36 systems (Foreign) 2017-02-28
2014-06-24 Class II Software design When using multiple isocenters (radiation treatment targets) within a single plan, in certain workflow conditions ExacTrac v.6.0.4 might move the patient to an unintended isocenter position, despite displaying the green “OK” icon. If this a 15 systems 2017-04-24
2014-04-15 Class II Software design When using a specific plan update workflow in combination with a non-Brainlab treatment planning system (TPS), there is a possibility in ExacTrac 5.5.5 to generate an unintended blend of two initially separate plans of the same patient. 40 systems (worldwide) 2017-04-24
2014-02-24 Class II Software design When using multiple radiation treatment targets within a single plan, the ExacTrac v.6.0.3 might position the patient to an unintended radiation treatment point. As a result, there is a possibility that the radiation treatment dose may be 41 systems (13 systems in US; 28 systems to foreign countrie 2017-04-24
2013-07-16 Class II Device Design The Frameless SRS QA Target Pointer – Pointer Cap with the engraved cross hairs may become loose even when only a moderate force is applied to the Pointer Cap. 6 units 2017-03-13
2009-03-19 Not classified Other The Integrated Multileaf-Collimator (MLC) of the linear accelerator could interfere with the intended conformal fields of the BrainLab m3 micro-Multileaf-Collimator (mMLC) during patient treatment. 13 units 2010-08-19
2009-03-19 Not classified Other The Integrated Multileaf-Collimator (MLC) of the linear accelerator could interfere with the intended conformal fields of the BrainLab m3 micro-Multileaf-Collimator (mMLC) during patient treatment. 1 unit 2010-08-19
2009-03-19 Not classified Other The Integrated Multileaf-Collimator (MLC) of the linear accelerator could interfere with the intended conformal fields of the BrainLab m3 micro-Multileaf-Collimator (mMLC) during patient treatment. 1 unit 2010-08-19
2009-03-19 Not classified Other The Integrated Multileaf-Collimator (MLC) of the linear accelerator could interfere with the intended conformal fields of the BrainLab m3 micro-Multileaf-Collimator (mMLC) during patient treatment. 35 units 2010-08-19

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer