CyberKnife® M6™ Systems

CyberKnife® M6™ Series (including configurations: M6 Neuro, M6 FI, M6 FIM, & M6 FM) The CyberKnife M6 Systems are computer-controlled medical systems for planning and performing minimally…

Registry build 21.09.26

CyberKnife® M6™ Series (including configurations: M6 Neuro, M6 FI, M6 FIM, & M6 FM) The CyberKnife M6 Systems are computer-controlled medical systems for planning and performing minimally invasive stereotactic radiosurgery and precision radiotherapy. They use a 6 MV linear accelerator mounted on a manipulator (robot) and a target locating subsystem to accurately deliver high-energy radiation (1000 MU/minute dose rate) to the treatment target. The target locating subsystem provides X-rays of the treatment area that lets the user know the position of the target. The CyberKnife M6 Systems use skull tracking, fiducial tracking (tracking of implanted radiographic markers), skeletal structure tracking, lung tumor tracking, Lung Optimized Treatment, and Synchrony Respiratory Tracking for dynamic positioning and pointing of the linear accelerator. The fixed, variable aperture and multileaf collimators are available as various beam-limiting secondary collimators.

8manufacturers in China registered for this device type
10catalogue numbers in this listing
19510(k) clearances naming this product code
38recalls on this code

Who Else Makes It

Concentrated in Guangdong (2), Jiangsu (2), Beijing (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code IYE
Manufacturer City Province Registered as Device types
Guangzhou Tian Hong Medical Technology Co., Ltd. Guangzhou Guangdong Contract manufacturer 4
Klarity Medical & Equipment (GZ) Co., Ltd. Guangzhou Guangdong Contract manufacturer 3
Elekta Beijing Medical Systems Co., Ltd. Beijing Beijing Contract manufacturer 1
Manteia Technologies Co., Ltd. Xiamen Fujian Manufacturer 3
OUR United Corporation Xian Shaanxi Contract manufacturer 2
Suzhou Linatech Medical Science AND Technology Co., Ltd. Suzhou Jiangsu Manufacturer 2
Varian Medical Systems China Co., Ltd. Beijing Beijing Manufacturer 2
Jiangsu Rayer Medical Technology Co., Ltd. Wuxi Jiangsu Manufacturer 1

Record

Regulatory record for CyberKnife® M6™ Systems
Listed by Accuray Incorporated, United States
FDA product code IYE
Device type Accelerator, Linear, Medical
Device class Class 2
Regulation 21 CFR 892.5050
Establishment Manufacturer
510(k) K122137
Record published 2016-09-22
Record revised 2021-08-09 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for CyberKnife® M6™ Systems
Catalogue number Size Status
053301-M-000 In distribution
1047641-000 In distribution
053401-M-000 In distribution
1047641-000 In distribution
053201-M-000 In distribution
053101-M-000 In distribution
053101-M-000 In distribution
053201-M-000 In distribution
053401-M-000 In distribution
053301-M-000 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Klarity Medical Klarity Medical Products, LLC 891
Orfit Industries Orfit Industries NV 680
Aquaplast RT™ Qfix 569
Fibreplast® Qfix 271
Bionix Radiation Therapy Bionix Radiation Therapy, LLC 115
Vac-Lok™ Cushion Medtec LLC 100
Visicoil IZI Medical Products LLC 86
BodyFIX 3C-Medical Intelligence GmbH 84
AlignRT Plus Vision RT Limited 72
Fibreplast® Assure™ Open View Qfix 72
Accelerator, Linear, Medical PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH 71
Thermoplastic Mask IZI Medical Products LLC 58

Showing 12 of 1,611. All products under Accelerator, Linear, Medical

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K223159 2023-06-23
K212794 2021-09-30
K202412 2020-12-18
K182687 2018-11-23
K171837 2017-07-25
K171086 2017-06-08
K161146 2016-06-24
K161144 2016-06-24
K150873 2015-07-01
K122137 2012-10-26
K121934 2012-08-29
K120233 2012-03-09
K102650 2010-11-17
K091999 2009-09-18
K072504 2007-09-21
K071531 2007-08-22
K041315 2004-06-10
K020294 2002-04-22
K011024 2001-08-10

Recalls Naming This Product

6 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of CyberKnife® M6™ Systems
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Accuray Incorporated 510(k) number 2018-09-26 Class II Process control A robotics supplier notified Accuray of two manufacturing variations in the fastening of the in-line wrist and the casting of the wrist for the robot. The variation may result in premature failure of the component. 93 units 2021-05-12
Accuray Incorporated 510(k) number 2018-04-10 Class II Other There is an unintended drop of a secondary collimator housing that can occur during housing Xchange(TM) workflows. Specifically, during an automated housing Xchange, an interlock may interrupt this operation causing the collimator housing 68 units 2021-04-01
Accuray Incorporated 510(k) number 2016-11-22 Class II Software design Accuray has become aware of a potential safety issue involving unexpected treatment robot motion when removing an accessory. This issue is limited to certain CyberKnife Systems with software version 1 0.6. 40 affected devices 2017-05-22
Accuray Incorporated 510(k) number 2014-10-31 Class II Software design Software upgrade to correct potential safety issue related to CyberKnife System that occurs when upgrading the Treatment Delivery Software for the first generation Iris Variable Aperture Collimator. 84 devices subject to correction. 2015-02-20
Accuray Incorporated 510(k) number 2014-01-13 Class II Device Design Potential Safety issue with Synchrony Boom Arm Mounting Assembly – one complaint of mounting assembly detaching. 302 devices; 149 in US, 153 out of US. 2014-11-25
Accuray Incorporated 510(k) number 2013-03-19 Class II Component design/selection A defect on the master-side connector block of the pneumatic tool changer could introduce a tilt in the collimator housings, resulting in a potential shift to the central axis of the radiation beam. The issue could pose significant clinical 176 units 2013-10-23

Recalls

18 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-06-16 Class II Software design In certain cases, a collimator may not fully dock, which triggers a system interlock and prevents motion from the operator console. If personnel then enter the treatment room and initiate motion using the in-room control pendant, the collim 48 units
2026-06-16 Class II Software design In certain cases, a collimator may not fully dock, which triggers a system interlock and prevents motion from the operator console. If personnel then enter the treatment room and initiate motion using the in-room control pendant, the collim 292 units
2024-12-23 Class II Component design/selection Snap rings may become partially or completed detached from the shafts within the internal mechanism. Uncontrolled rotation may occur on the left and right roll axes when the rings are removed or damaged. 212
2023-08-03 Class II Device Design It is possible the upper roller bracket in the Radixact System gantry enclosure may not provide enough clearance for service personnel to use a jib crane for moving components while servicing the system, resulting in possible injury to the 82
2021-02-26 Class II Equipment maintenance The set screws that connect the Standard Treatment Couch linkage arm to the roll motor can loosen over time allowing the couch to roll. 243 units 2022-06-27
2020-12-10 Class II Software Design Change “MLC tickle error” may result in the delivered dose to effectively rotate from the planned dose. 7 units 2022-09-26
2020-12-10 Class II Software Design Change “MLC tickle error” may result in the delivered dose to effectively rotate from the planned dose. 8 units 2022-09-26
2018-08-31 Class II Nonconforming Material/Component the Ball Cube II phantom calibration film was not manufactured within necessary dimensions and may introduce up to 0.5 mm of positional inaccuracy to the CyberKnife System 259 units 2020-12-16
2018-04-10 Class II Other There is an unintended drop of a secondary collimator housing that can occur during housing Xchange(TM) workflows. Specifically, during an automated housing Xchange, an interlock may interrupt this operation causing the collimator housing 43 units 2021-04-01
2017-11-17 Class II Software design Uncontrolled couch Z-axis movement (descent) 87 units 2021-07-25
2017-11-17 Class II Software design Uncontrolled couch Z-axis movement (descent) 250 units 2021-07-25
2017-11-17 Class II Software design Uncontrolled couch Z-axis movement (descent) 118 units 2021-07-25
2017-11-17 Class II Software design Uncontrolled couch Z-axis movement (descent) 29 units 2021-07-25
2016-12-06 Class II Device Design Accuray has become aware of a potential safety issue involving the possibility of electric shock during
maintenance activities from the lon Pump HV Power Supply at the back of the modulator cabinet. This issue is limited to certain G3, G4,
115 affected devices. 2017-06-09
2016-01-22 Class II Device Design The gun box mounting bracket may fail to support the weight of the gun box when in vertical (inverted) position. If this failure occurs the gun box may become loose and could come into contact with a patient. 226 2016-10-20
2014-11-21 Class II Software design Accuray has become aware of a potential safety issue related to the TomoTherapy Treatment System caused by a failure to monitor the jaw position after a jaw error occurs. This may result in an incorrect jaw position during treatment, witho 210 ( 72 USA; 138 OUS ) 2015-07-17
2014-07-17 Class II Software design Accuray is voluntarily recalling TomoTherapy H Series software versions 1.2.0, 1.2.1 and 1.2.2 (Hi-Art 4.2.0, 4.2.1 and 4.2.2).
Accuray has identified potential safety issues (anomalies) with these software versions.
322 2015-09-08
2014-07-16 Class II Software design Accuray is voluntarily recalling TomoTherapy H Series software versions 2.0.0 and 2.0.1 (Hi-Art 5.0.0 and 5.0.1). Accuray has identified potential safety issues (anomalies) with these software versions. 168 (75 US; 93 OUS) 2015-07-21
2012-01-16 Not classified Software design An anomaly was discovered during internal regression testing, where the dose information is displayed incorrectly during treatment planning during a specific workflow using the optional 4D Ray Tracing dose calculation algorithm. As a result 207 2012-09-28
2011-11-07 Not classified Labeling design User Facility reported an anomaly where inhale and exhale CT pairs used for treatment planning did not represent the same magnitude of respiration that was displayed during treatment delivery. 30 2012-02-27
2011-09-12 Not classified Process control A report and investigation determined that the set screws, which were part of the retrofit of a previous recall were incorrectly engaged which allowed rotation and subsequent descent of the assembly. 236 total devices 2012-02-27
2011-09-12 Not classified Process control A report and investigation determined that the set screws, which were part of the retrofit of a previous recall were incorrectly engaged at one facility which allowed rotation and subsequent descent of the assembly. 236 total devices 2012-02-27
2010-10-28 Not classified Other If users modify the dose calculation box to cover just the contoured anatomy and not the entire CT volume, dosage may not be properly calculated. 219 units 2011-04-01
2009-06-22 Not classified Software design Targeting accuracy out of specification, Error alert does not render the system down, which may result in mistreatment in the wrong area. 61 units 2011-01-05
2009-03-16 Not classified Device Design The product has the potential for the extension coupling of the Synchrony extension mounting hardware to become loose over time. The assembly weighs approximately 17 pounds; an unexpected contact with users or patients may result in serious 2011-01-19
2009-03-16 Not classified Device Design The product has the potential for the extension coupling of the Synchrony extension mounting hardware to become loose over time. The assembly weighs approximately 17 pounds; an unexpected contact with users or patients may result in serious 2011-01-19
2008-11-14 Not classified Software design System may use random incorrect data to calculate dose. Resulting dose calculation error can exceed 100% of correct dose which may lead to serious patient injury. 4 units 2010-12-02
2008-10-14 Not classified Software design TomoTherapy Incorporated identified a potential issue with the Hi-Art system during the course of ongoing testing.

The Operator Station Calibration panel provides access to view and modify machine specific configuration settings. Access

215 2011-02-10
2008-09-18 Not classified Software design TomoTherapy Inc. discovered an issue on the Hi-Art system during the course of ongoing testing. It has been identified that treatment plans involving very small structures (volume <2cc), reading in a high dose gradient region, may exhibit 165 2011-04-19
2008-05-01 Not classified Software design Couch may move unexpectedly, which may result in patient impacting the linear accelerator. 105 units 2010-11-30
2008-04-09 Not classified Software design Sample beam data (which should not be used to treat patients) may differ from actual radiation output of an installed product, and which may be used by users. 109 units 2010-11-30
2008-02-22 Not classified Software design Registration adjustment field numbers may appear on printed pages of the Register Tab as nonsense characters or values different than the numbers shown on the Operator Station (OS) display.

Setup will move the couch to the correct offset po

32 2008-12-02

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA.

Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer