Elekta Medical Linear Accelerator

Elekta Harmony Pro

Registry build 21.09.26
8manufacturers in China registered for this device type
8catalogue numbers in this listing
5510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Guangdong (2), Jiangsu (2), Beijing (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code IYE
Manufacturer City Province Registered as Device types
Guangzhou Tian Hong Medical Technology Co., Ltd. Guangzhou Guangdong Contract manufacturer 4
Klarity Medical & Equipment (GZ) Co., Ltd. Guangzhou Guangdong Contract manufacturer 3
Elekta Beijing Medical Systems Co., Ltd. Beijing Beijing Contract manufacturer 1
Manteia Technologies Co., Ltd. Xiamen Fujian Manufacturer 3
OUR United Corporation Xian Shaanxi Contract manufacturer 2
Suzhou Linatech Medical Science AND Technology Co., Ltd. Suzhou Jiangsu Manufacturer 2
Varian Medical Systems China Co., Ltd. Beijing Beijing Manufacturer 2
Jiangsu Rayer Medical Technology Co., Ltd. Wuxi Jiangsu Manufacturer 1

Record

Regulatory record for Elekta Medical Linear Accelerator
Listed by Elekta Solutions AB, Sweden
FDA product code IYE
Device type Accelerator, Linear, Medical
Device class Class 2
Regulation 21 CFR 892.5050
Establishment Specification developer, Manufacturer, Exporter
Record published 2021-07-30
Record revised 2025-06-12 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Elekta Medical Linear Accelerator
Catalogue number Size Status
1555143 In distribution
1550357 In distribution
1552092 In distribution
1552093 In distribution
1550359 In distribution
1550358 In distribution
1553032 In distribution
1552091 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Klarity Medical Klarity Medical Products, LLC 891
Orfit Industries Orfit Industries NV 680
Aquaplast RT™ Qfix 569
Fibreplast® Qfix 271
Bionix Radiation Therapy Bionix Radiation Therapy, LLC 115
Vac-Lok™ Cushion Medtec LLC 100
Visicoil IZI Medical Products LLC 86
BodyFIX 3C-Medical Intelligence GmbH 84
AlignRT Plus Vision RT Limited 72
Fibreplast® Assure™ Open View Qfix 72
Accelerator, Linear, Medical PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH 71
Thermoplastic Mask IZI Medical Products LLC 58

Showing 12 of 1,611. All products under Accelerator, Linear, Medical

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K252188 2026-01-15
K223229 2023-02-23
K223209 2023-02-23
K212114 2021-10-01
K203172 2020-12-18

Recalls Naming This Product

6 recalls name this product by its own identifiers, the UDI on its label.

Recalls naming the identifiers of Elekta Medical Linear Accelerator
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Elekta Inc. UDI-DI 2023-10-25 Class II Under Investigation by firm Elekta has identified that if the microswitch within the middle arm is incorrectly setup, there is a potential for an uncontrolled extension of iViewGT / XVI detector arms. When the detector arm is fully deployed there is no risk of uncont 1019 units
Elekta Inc. UDI-DI 2023-10-25 Class II Under Investigation by firm Elekta has identified that if the microswitch within the middle arm is incorrectly setup, there is a potential for an uncontrolled extension of iViewGT / XVI detector arms. When the detector arm is fully deployed there is no risk of uncont 451 units
Elekta Inc. UDI-DI 2023-10-25 Class II Under Investigation by firm Elekta has identified that if the microswitch within the middle arm is incorrectly setup, there is a potential for an uncontrolled extension of iViewGT / XVI detector arms. When the detector arm is fully deployed there is no risk of uncont 291 units
Elekta Inc. UDI-DI 2023-05-05 Class II Under Investigation by firm A component within a limited number of Elekta Linacs has been realized to be non-compliant to IEC 60601 46 units
Elekta Solutions AB UDI-DI 2021-09-28 Class II Nonconforming Material/Component There is a risk that the Diode D1 in the Modulator can fail in a destructive manner when removed from the machine, and that the protective tube surrounding the diode may fail to contain the ejected matter. 2 in the U.S. 2024-06-14
Elekta Inc. UDI-DI 2021-09-17 Class II Under Investigation by firm There is a risk that the Diode D1 in the Modulator can fail in a destructive manner when removed from the machine, and that the protective tube surrounding the diode may fail to contain the ejected matter. 4,405 units 2024-09-30

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2025-09-17 Class II Software design When appending a care plan that contains one or more wave medication orders, the occurrence and
frequency of the appended orders may not match the intended schedule.
4 systems that contain the affected software.

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer