Elekta Unity

Indexing Bars

Registry build 21.09.26
8manufacturers in China registered for this device type
6catalogue numbers in this listing
19510(k) clearances naming this product code
40recalls on this code

Who Else Makes It

Concentrated in Guangdong (2), Jiangsu (2), Beijing (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code IYE
Manufacturer City Province Registered as Device types
Guangzhou Tian Hong Medical Technology Co., Ltd. Guangzhou Guangdong Contract manufacturer 4
Klarity Medical & Equipment (GZ) Co., Ltd. Guangzhou Guangdong Contract manufacturer 3
Elekta Beijing Medical Systems Co., Ltd. Beijing Beijing Contract manufacturer 1
Manteia Technologies Co., Ltd. Xiamen Fujian Manufacturer 3
OUR United Corporation Xian Shaanxi Contract manufacturer 2
Suzhou Linatech Medical Science AND Technology Co., Ltd. Suzhou Jiangsu Manufacturer 2
Varian Medical Systems China Co., Ltd. Beijing Beijing Manufacturer 2
Jiangsu Rayer Medical Technology Co., Ltd. Wuxi Jiangsu Manufacturer 1

Record

Regulatory record for Elekta Unity
Listed by Elekta Inc., United States
FDA product code IYE
Device type Accelerator, Linear, Medical
Device class Class 2
Regulation 21 CFR 892.5050
Establishment Contract manufacturer, Manufacturer
510(k) K182076
Record published 2021-11-30
Record revised 2022-11-14 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Elekta Unity
Catalogue number Size Status
1553106 In distribution
1075900 In distribution
1065120 In distribution
1059073 In distribution
1536549 In distribution
1082525 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Klarity Medical Klarity Medical Products, LLC 891
Orfit Industries Orfit Industries NV 680
Aquaplast RT™ Qfix 569
Fibreplast® Qfix 271
Bionix Radiation Therapy Bionix Radiation Therapy, LLC 115
Vac-Lok™ Cushion Medtec LLC 100
Visicoil IZI Medical Products LLC 86
BodyFIX 3C-Medical Intelligence GmbH 84
AlignRT Plus Vision RT Limited 72
Fibreplast® Assure™ Open View Qfix 72
Accelerator, Linear, Medical PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH 71
Thermoplastic Mask IZI Medical Products LLC 58

Showing 12 of 1,611. All products under Accelerator, Linear, Medical

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K210500 2021-06-11
K192482 2019-12-05
K192242 2019-11-22
K182076 2018-12-04
K183034 2018-12-04
K153011 2015-12-11
K141855 2014-10-08
K131965 2013-09-25
K123808 2013-04-04
K121663 2012-12-05
K121328 2012-06-12
K111332 2012-01-30
K112613 2011-12-16
K102200 2010-11-04
K100115 2010-03-10
K082122 2008-08-29
K080585 2008-06-11
K051932 2005-08-12
K042794 2005-01-31

Recalls Naming This Product

6 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.

Recalls naming the identifiers of Elekta Unity
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Elekta Inc. UDI-DI 2023-04-06 Class II Process design There is a low possibility that an electrical connector in the MR gradient coil will overheat on Elekta Unity systems. 18 devices
Elekta Inc. UDI-DI 2020-05-21 Class II Device Design In TSM (Treatment Session Manager) Motion Monitoring workflows, under certain conditions there can be a mismatch between the contour data overlay with respect to the motion monitoring images of the monitored structure. 26 units 2024-08-19
Elekta Inc. 510(k) number 2019-06-24 Class II Software design The QA software solution to perform the MR to MV alignment check, does not display the stored MR to MV offset values. The user is unable to independently inspect the values during their QA. 12 units 2021-04-01
Elekta Inc. 510(k) number 2019-04-03 Class II Labeling design There is no warning in the Elekta Unity manual for the administration of gadolinium-based or other contrast agents for imaging or image guidance purposes has not been validated. 9 devices 2023-05-01
Elekta Inc. 510(k) number 2019-03-12 Class II Software design Users need to be aware when using these protocols for daily on line plan adaptation that:
1) The images acquired using these protocols do not represent the average position of the anatomy during the respiratory motion cycle. The images are
12 units 2023-11-03
Elekta Inc. 510(k) number 2019-01-04 Class II Under Investigation by firm In rare circumstances, due to reasons such as inadequate hospital facility maintenance, water leakage, and weakening of speaker fixings during the lifetime of the system, the speakers can become dislodged and be pulled into the bore. 2 units

Recalls

34 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-05-21 Class II Software design Software may fail to load adapted baseline shift plan during treatment delivery when a communication error occurs. 12 programs
2025-12-14 Class II Process control Due to a manufacturing issue and electrical grounding of systems. 5391
2025-12-10 Class II Software change control Using oncology information system that manages workflow may result in overtreatment if:Plan delivered with Particle Therapy IHE-RO TDW-II interface,With one field per fraction or last field partial treatment,Partial treatment occurs followe 1
2025-01-15 Class II Software design Image offsets calculated by oncology Information System
software may be incorrect for Linear Accelerator (LINACs) not characterized at IEC61217 scale.
64 units
2023-10-25 Class II Under Investigation by firm Elekta has identified that if the microswitch within the middle arm is incorrectly setup, there is a potential for an uncontrolled extension of iViewGT / XVI detector arms. When the detector arm is fully deployed there is no risk of uncont 291 units
2023-10-25 Class II Under Investigation by firm Elekta has identified that if the microswitch within the middle arm is incorrectly setup, there is a potential for an uncontrolled extension of iViewGT / XVI detector arms. When the detector arm is fully deployed there is no risk of uncont 264 units
2023-10-25 Class II Under Investigation by firm Elekta has identified that if the microswitch within the middle arm is incorrectly setup, there is a potential for an uncontrolled extension of iViewGT / XVI detector arms. When the detector arm is fully deployed there is no risk of uncont 1019 units
2023-10-25 Class II Under Investigation by firm Elekta has identified that if the microswitch within the middle arm is incorrectly setup, there is a potential for an uncontrolled extension of iViewGT / XVI detector arms. When the detector arm is fully deployed there is no risk of uncont 47 units
2023-10-25 Class II Under Investigation by firm Elekta has identified that if the microswitch within the middle arm is incorrectly setup, there is a potential for an uncontrolled extension of iViewGT / XVI detector arms. When the detector arm is fully deployed there is no risk of uncont 451 units
2023-10-25 Class II Under Investigation by firm Elekta has identified that if the microswitch within the middle arm is incorrectly setup, there is a potential for an uncontrolled extension of iViewGT / XVI detector arms. When the detector arm is fully deployed there is no risk of uncont 315 units
2023-05-05 Class II Under Investigation by firm A component within a limited number of Elekta Linacs has been realized to be non-compliant to IEC 60601 46 units
2021-09-17 Class II Under Investigation by firm There is a risk that the Diode D1 in the Modulator can fail in a destructive manner when removed from the machine, and that the protective tube surrounding the diode may fail to contain the ejected matter. 4,405 units 2024-09-30
2021-09-02 Class II Software design A drug strength in MOSAIQ can be changed during the ordering process and approved, but the saved drug strength reverts to the original value. 31
2021-04-20 Class II Under Investigation by firm Malware attack 40 units 2023-01-17
2020-04-30 Class II Under Investigation by firm potential risk that Legionella may be present in the Unity machine room, specifically the heat exchanger condensation collection tray. 32 units 2021-08-04
2019-12-18 Class II Process control There have been reports of excessive heating in the MRL Gradient Connection Module. 21 devices 2021-06-15
2019-06-19 Class II Software Design Change Potential for iGUIDE to incorrectly monitor the 3D position. 374 devices 2024-05-06
2018-12-13 Class II Software change control There is a potential that Wedge IDs were not included in the DICOM RT PLAN sent from the TPS, which will cause the field in MOSAIQ to be created with no wedge. Treatment of a field without the planned wedge will receive more dose than the 3,950 units total (1,747 US)
2018-12-04 Class II Software design If a Setup field (CT, kV, MV or MVCT) is created by COPYING a treatment field or another setup field, then the
copied field will have the same isocenter as the parent and that isocenter may not be the correct isocenter for
imaging when it i
551 units 2026-02-23
2018-08-03 Class II Unknown/Undetermined by firm Order Status Remains Approved When Should Indicate Complete. 185 2024-09-23
2017-12-01 Class II Component design/selection There is a potential for an uncontrolled extension of iViewGT / XVI detector arms. 2,998 2019-11-05
2017-11-20 Class II Software Design Change Potential for positional errors following automatic table movement (ATM). 539 units total 2024-03-15
2017-11-20 Class II Software Design Change Potential for positional errors following automatic table movement (ATM). 539 units total 2024-03-15
2017-06-21 Class II Software design Retention of Outdated Information in an Order Set. In the Care Plan Library, double clicking to add or delete a Component/Procedure to an Order Set does not trigger the update of the associated Care Plans. 355 units 2018-07-11
2017-06-19 Class II Unknown/Undetermined by firm Incorrect PEC values. 110 units 2019-11-05
2016-12-02 Class II Software design Edits to Particle field definition parameters may not be saved when the field definition window is saved. 47 2021-11-05
2016-08-18 Class II Nonconforming Material/Component Potentially unrecognized incorrect position of the treatment couch in 3D workflow, i.e. the HexaPOD has not moved fully to the 3D position. 13 2017-05-23
2016-07-15 Class II Software Design Change It is possible that a change to an Order Set will not be saved in the current open Care Plan. This can result in a wrong chemo dose in the order. 383
2016-07-08 Class II Other There have been instances in hospitals where the joint between the drive gear and the gantry base drive wheel has become loose, leading to fatigue failure of some of the securing bolts. 553 2017-11-24
2016-06-17 Class II Software design It is possible that that the selected Plan-of-the Day could be accidently changed by scrolling the mouse wheel up and down and inadvertently selecting another plan. 69 2020-08-18
2016-05-12 Class II Software design If by mistake the initial pre-treatment imaging was performed BEFORE the HexaPOD was moved to the DRIVE (*START) position, iGUIDE offers the possibility to branch into a specific catch-up workflow, which was implemented to use the initial s 20 2021-07-16
2015-12-09 Class II Software design Incorrect drug dosage due to “Age Limit” and patient weight data item issue. 399 2022-09-27
2015-11-24 Class II Software design First Databank (FDB) is a third party product incorporated into MOSAIQ. FDB routinely modifies drugs in their database to reflect market and formulary changes. In FDB Framework v2.0, those drugs are not being included in drug-drug, drug-all 211 2021-09-15
2015-07-01 Class II Software design A problem exists in MOSAIQ resulting in the incorrect field size being sent to the treatment machine for stereotactic plans using cones. 74 Total (45 US) 2021-09-15

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer