MapRT Acquisition Software

MapRT is used to assist treatment planning whereby the patient surface and positioning devices captured at simulation can be modelled against the treatment devices, such that any potential…

Registry build 21.09.26

MapRT is used to assist treatment planning whereby the patient surface and positioning devices captured at simulation can be modelled against the treatment devices, such that any potential collisions can be predicted.

8manufacturers in China registered for this device type
1catalogue number
11510(k) clearances naming this product code
5recalls on this code

Who Else Makes It

Concentrated in Guangdong (2), Jiangsu (2), Beijing (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code IYE
Manufacturer City Province Registered as Device types
Guangzhou Tian Hong Medical Technology Co., Ltd. Guangzhou Guangdong Contract manufacturer 4
Klarity Medical & Equipment (GZ) Co., Ltd. Guangzhou Guangdong Contract manufacturer 3
Elekta Beijing Medical Systems Co., Ltd. Beijing Beijing Contract manufacturer 1
Manteia Technologies Co., Ltd. Xiamen Fujian Manufacturer 3
OUR United Corporation Xian Shaanxi Contract manufacturer 2
Suzhou Linatech Medical Science AND Technology Co., Ltd. Suzhou Jiangsu Manufacturer 2
Varian Medical Systems China Co., Ltd. Beijing Beijing Manufacturer 2
Jiangsu Rayer Medical Technology Co., Ltd. Wuxi Jiangsu Manufacturer 1

Record

Regulatory record for MapRT acquisition software
Listed by Vision RT Limited, United Kingdom
FDA product code IYE
Device type Accelerator, Linear, Medical
Device class Class 2
Regulation 21 CFR 892.5050
Establishment Specification developer, Private-label distributor, Complaint-file establishment, Manufacturer
Record published 2023-06-26

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for MapRT acquisition software
Catalogue number Size Status
MapRT acquisition software In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Klarity Medical Klarity Medical Products, LLC 891
Orfit Industries Orfit Industries NV 680
Aquaplast RT™ Qfix 569
Fibreplast® Qfix 271
Bionix Radiation Therapy Bionix Radiation Therapy, LLC 115
Vac-Lok™ Cushion Medtec LLC 100
Visicoil IZI Medical Products LLC 86
BodyFIX 3C-Medical Intelligence GmbH 84
AlignRT Plus Vision RT Limited 72
Fibreplast® Assure™ Open View Qfix 72
Accelerator, Linear, Medical PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH 71
Thermoplastic Mask IZI Medical Products LLC 58

Showing 12 of 1,611. All products under Accelerator, Linear, Medical

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K253012 2026-03-18
K243301 2025-05-19
K233622 2024-03-29
K231185 2023-06-23
K212583 2021-11-10
K203387 2021-03-04
K193431 2020-01-03
K181218 2018-08-07
K123371 2013-01-08
K072171 2007-10-01
K052682 2006-01-06

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2018-08-24 Class II Software design RTInterface error in the event of an I/O error between the IGC PCB and the Framegrabber PCB 690 systens 2022-07-08
2016-06-30 Class II Other Vision RT Ltd received three (3) reports from different sites that discovered the following issue, unintended changes were made to planned couch parameters, specifically the couch rotation parameter, during patient set-up for the Optical Su 47 2017-09-20
2016-06-30 Class II Other Vision RT Ltd received three (3) reports from different sites that discovered the following issue, unintended changes were made to planned couch parameters, specifically the couch rotation parameter, during patient set-up for the Optical Su 47 2017-09-20
2014-11-11 Class II Under Investigation by firm Potential use error when the external Gate Controller is turned ON after the Vision RT software has been opened. 55 2016-05-11
2014-10-15 Class II Software in the Use Environment Potential failure of AlignRT to assert interlock. 7 (Six Units distribited in the US and One in OUS.) 2016-05-10

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker