Mosaiq
6 catalogue numbers from MOSAIQ, listed by Elekta Solutions AB, Sweden, under Accelerator, Linear, Medical. 8 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (2), Jiangsu (2), Beijing (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Guangzhou Tian Hong Medical Technology Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 4 |
| Klarity Medical & Equipment (GZ) Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 3 |
| Elekta Beijing Medical Systems Co., Ltd. | Beijing | Beijing | Contract manufacturer | 1 |
| Manteia Technologies Co., Ltd. | Xiamen | Fujian | Manufacturer | 3 |
| OUR United Corporation | Xian | Shaanxi | Contract manufacturer | 2 |
| Suzhou Linatech Medical Science AND Technology Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 2 |
| Varian Medical Systems China Co., Ltd. | Beijing | Beijing | Manufacturer | 2 |
| Jiangsu Rayer Medical Technology Co., Ltd. | Wuxi | Jiangsu | Manufacturer | 1 |
Record
| Listed by | Elekta Solutions AB, Sweden |
|---|---|
| FDA product code | IYE |
| Device type | Accelerator, Linear, Medical |
| Device class | Class 2 |
| Regulation | 21 CFR 892.5050 |
| Establishment | Specification developer, Manufacturer, Exporter |
| 510(k) | K183034 |
| Record published | 2019-05-29 |
| Record revised | 2025-06-12 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number |
| Distribution end date | 2025-03-01 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| MOSAIQ | In distribution | |
| MOSAIQ | In distribution | |
| MOSAIQ | In distribution | |
| MOSAIQ | In distribution | |
| 3.2 | In distribution | |
| MOSAIQ | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Klarity Medical | Klarity Medical Products, LLC | 891 |
| Orfit Industries | Orfit Industries NV | 680 |
| Aquaplast RT™ | Qfix | 569 |
| Fibreplast® | Qfix | 271 |
| Bionix Radiation Therapy | Bionix Radiation Therapy, LLC | 115 |
| Vac-Lok™ Cushion | Medtec LLC | 100 |
| Visicoil | IZI Medical Products LLC | 86 |
| BodyFIX | 3C-Medical Intelligence GmbH | 84 |
| AlignRT Plus | Vision RT Limited | 72 |
| Fibreplast® Assure™ Open View | Qfix | 72 |
| Accelerator, Linear, Medical | PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH | 71 |
| Thermoplastic Mask | IZI Medical Products LLC | 58 |
Showing 12 of 1,611. All products under Accelerator, Linear, Medical
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K252188 | 2026-01-15 |
| K223229 | 2023-02-23 |
| K223209 | 2023-02-23 |
| K212114 | 2021-10-01 |
| K203172 | 2020-12-18 |
Recalls Naming This Product
6 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Elekta Inc. | 510(k) number | 2026-05-21 | Class II | Software design | Software may fail to load adapted baseline shift plan during treatment delivery when a communication error occurs. | 12 programs | |
| Elekta Inc. | 510(k) number | 2025-12-10 | Class II | Software change control | Using oncology information system that manages workflow may result in overtreatment if:Plan delivered with Particle Therapy IHE-RO TDW-II interface,With one field per fraction or last field partial treatment,Partial treatment occurs followe | 1 | |
| Elekta Solutions AB | 510(k) number | 2025-09-17 | Class II | Software design | When appending a care plan that contains one or more wave medication orders, the occurrence and frequency of the appended orders may not match the intended schedule. | 4 systems that contain the affected software. | |
| Elekta Inc. | 510(k) number | 2025-01-15 | Class II | Software design | Image offsets calculated by oncology Information System software may be incorrect for Linear Accelerator (LINACs) not characterized at IEC61217 scale. | 64 units | |
| Elekta Inc. | 510(k) number | 2021-09-02 | Class II | Software design | A drug strength in MOSAIQ can be changed during the ordering process and approved, but the saved drug strength reverts to the original value. | 31 | |
| Elekta Inc. | 510(k) number | 2021-04-20 | Class II | Under Investigation by firm | Malware attack | 40 units | 2023-01-17 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2021-09-28 | Class II | Nonconforming Material/Component | There is a risk that the Diode D1 in the Modulator can fail in a destructive manner when removed from the machine, and that the protective tube surrounding the diode may fail to contain the ejected matter. | 2 in the U.S. | 2024-06-14 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.