Novalis TX

2 catalogue numbers from 9.5, listed by Varian Medical Systems, Inc, United States, under Accelerator, Linear, Medical. 8 manufacturers in China are registered for this product code.

Registry build 21.09.26
8manufacturers in China registered for this device type
2catalogue numbers in this listing
83510(k) clearances naming this product code
40recalls on this code

Who Else Makes It

Concentrated in Guangdong (2), Jiangsu (2), Beijing (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code IYE
Manufacturer City Province Registered as Device types
Guangzhou Tian Hong Medical Technology Co., Ltd. Guangzhou Guangdong Contract manufacturer 4
Klarity Medical & Equipment (GZ) Co., Ltd. Guangzhou Guangdong Contract manufacturer 3
Elekta Beijing Medical Systems Co., Ltd. Beijing Beijing Contract manufacturer 1
Manteia Technologies Co., Ltd. Xiamen Fujian Manufacturer 3
OUR United Corporation Xian Shaanxi Contract manufacturer 2
Suzhou Linatech Medical Science AND Technology Co., Ltd. Suzhou Jiangsu Manufacturer 2
Varian Medical Systems China Co., Ltd. Beijing Beijing Manufacturer 2
Jiangsu Rayer Medical Technology Co., Ltd. Wuxi Jiangsu Manufacturer 1

Record

Regulatory record for Novalis TX
Listed by Varian Medical Systems, Inc, United States
FDA product code IYE
Device type Accelerator, Linear, Medical
Device class Class 2
Regulation 21 CFR 892.5050
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K181404
Record published 2018-07-31
Record revised 2023-06-20 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Novalis TX
Catalogue number Size Status
9.5 In distribution
9.1 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Klarity Medical Klarity Medical Products, LLC 891
Orfit Industries Orfit Industries NV 680
Aquaplast RT™ Qfix 569
Fibreplast® Qfix 271
Bionix Radiation Therapy Bionix Radiation Therapy, LLC 115
Vac-Lok™ Cushion Medtec LLC 100
Visicoil IZI Medical Products LLC 86
BodyFIX 3C-Medical Intelligence GmbH 84
AlignRT Plus Vision RT Limited 72
Fibreplast® Assure™ Open View Qfix 72
Accelerator, Linear, Medical PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH 71
Thermoplastic Mask IZI Medical Products LLC 58

Showing 12 of 1,611. All products under Accelerator, Linear, Medical

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K261856 2026-08-03
K252977 2026-01-21
K252919 2025-12-16
K252948 2025-10-07
K250099 2025-05-16
K242957 2025-02-07
K232923 2024-04-30
K232870 2023-12-21
K232113 2023-11-03
K231317 2023-09-12
K230576 2023-07-25
K223839 2023-05-22
K230699 2023-04-10
K222941 2023-01-17
K221408 2022-06-17
K221448 2022-06-15
K213977 2022-06-03
K212294 2021-08-20
K210835 2021-04-20
K203669 2021-01-14
K192377 2020-02-10
K192968 2019-11-12
K192424 2019-10-03
K191761 2019-07-31
K190137 2019-07-10
K181404 2018-06-28
K181032 2018-05-09
K170570 2018-04-06
K180586 2018-04-02
K173838 2018-01-17
K172013 2017-07-28
K171733 2017-07-12
K170817 2017-06-27
K162472 2017-01-19
K162476 2016-12-12
K152761 2015-11-25
K151882 2015-10-26
K150706 2015-05-08
K143224 2014-12-19
K142560 2014-12-11
K142268 2014-10-02
K140528 2014-09-05
K140823 2014-06-27
K133572 2014-04-04
K133227 2014-03-14
K133240 2014-01-31
K132705 2013-10-31
K131807 2013-10-11
K123788 2013-01-15
K123291 2012-12-20
K123137 2012-12-05
K112778 2011-12-29
K112839 2011-11-14
K111106 2011-08-18
K102024 2010-10-15
K100890 2010-07-13
K093967 2010-07-12
K093527 2009-12-15
K092871 2009-11-30
K091209 2009-06-23
K091132 2009-06-17
K081188 2008-07-14
K081036 2008-05-09
K072916 2007-11-09
K071992 2007-08-15
K071360 2007-06-08
K070094 2007-02-09
K063270 2006-12-14
K062618 2006-09-22
K061140 2006-05-15
K052391 2005-11-23
K050479 2005-03-24
K050442 2005-03-23
K042956 2005-03-11
K042720 2004-10-29
K041519 2004-08-04
K040192 2004-02-27
K033343 2003-12-23
K010975 2001-05-02
K003636 2001-02-02
K001643 2000-06-23
K973889 1997-11-21
K962950 1997-07-22

Recalls Naming This Product

2 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Novalis TX
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Varian Medical Systems, Inc 510(k) number 2019-08-12 Class II Software Design Change After a recent upgrade to the collimator software version 8.5, the firm became aware that the multi-leaf collimator leaves did not move during an arc treatment. The issue is related to a transient carriage primary- secondary interlock due t 151 units 2021-01-21
Varian Medical Systems, Inc 510(k) number 2013-10-24 Class II Device Design This correction is to notify users that a solution to a previous correction has been developed and Varians reps will be contacting locations to schedule installation. 3,809 devices 2016-01-13

Recalls

15 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2018-08-20 Class II Software design Reports have been received of an anomaly that can result in a treatment without intended gating (respiratory tracking/monitoring). This issue occurs when a patient planned with gating is treated on more than one system. 387 2020-08-28
2018-08-20 Class II Software design Reports have been received of an anomaly that can result in a treatment without intended gating (respiratory tracking/monitoring). This issue occurs when a patient planned with gating is treated on more than one system. 4 2020-08-28
2016-12-02 Class II Device Design Modifications in version 13.6MR2 for Contouring, SmartAdapt, and SmartSegmentation workspaces resulted in contours not being saved consistently in Eclipse. Treatment Planning System. The issue only occurs if certain conditions are fulfilled 42 devices are affected 2017-05-12
2016-09-13 Class II Device Design Varian Medical Systems has received a report that a user was able to easily rotate the head frame posts when attached to the mounting cam on the metal head ring. There was no report of serious injury due to this issue 75 devices 2017-02-24
2016-06-23 Class II Software design Varian Medical Systems has received reports that unintended changes were made to planned couch
parameters, specifically the couch rotation parameter, during patient set-up. This can occur when a user
sets a different couch rotation from the
21 AlignRT Plus in US, 1 International. 2018-08-24
2016-06-23 Class II Software design Varian Medical Systems has received reports that unintended changes were made to planned couch parameters, specifically the couch rotation parameter, during patient set-up. This can occur when a user sets a different couch rotation from the 166 OSMS in US, 23 OSMO – International, 2018-08-24
2014-06-17 Class II Radiation Control for Health and Safety Act Trend in reports of unexpected decrease in beam output in C-series High Energy Linear Accelerators for 6MV photon treatment mode. 3416 2018-09-20
2014-04-30 Class II Component change control Varian MedicalSystems’ X-ray generator Supplier (CPI) has identified that 32 VMS150 X-ray Generators were shipped that are missing a ground wire between the EMIbraid on the induc­ tion assembly cable and the ground stud on the lid of the Hi 32 units 2015-03-16
2014-03-20 Class II Equipment maintenance Varian has identified a failure with the shaft of the Type 01 elbow motor for Exact arms used in the On-Board Imager (OBI) device due to belt over-tensioning. 2622 2015-05-01
2013-03-26 Class II Device Design Varian has identified an anomaly with the RPM Respiratory Gating System version I.7.5 with 3D Option. While operating with the 6-dot marker block, this version of RPM Gating may produce an inverted respiratory waveform in amplitude and pha 2508 units 2014-07-09
2012-11-05 Class II Software design Varian Medical Systems has identified an anomaly with the ARIA Oncology Information System Radiation Oncology [ARIA RO] DICOM import/export functionality where a 360 degree arc field may convert to static field during DICOM export or import 264 units 2014-03-03
2012-09-24 Class II Software design An anomaly has been identified with the ARIA Oncology Information System Version 11 where Monitor Units of one fraction may be incorrect, when partial treatment is being continued. 205 2013-12-05
2012-08-14 Class II Nonconforming Material/Component Some X-jaw (lower collimator jaw) carriers were made using the incorrect metal alloy, which can cause the jaw carrier to crack. If both carriers on the same X-jaw crack, the jaw would be able to move freely in the closed direction. The pos 221 Units 2013-12-04
2012-07-02 Class II Software design A software anomaly has been identified with the Import Export Application version 11.0 where
MLC leaf positions for plans using BrainLab m3 and mMLC are incorrectly imported.
2 Units. 2013-07-01
2012-04-09 Not classified Device Design A software anomaly has been identified in TrueBeam when using respiratory gating with patients in the prone position. The gating curve is inverted when a prone patient plan is loaded into TrueBeam. 207 devices ***12-12-12 AMENDED TO: 216 UNITS*** 2014-04-16
2012-04-09 Not classified Labeling design Varian received a report involving a Gantry collision and is sending a notification to remind users of the collision protection tools available with TrueBeam and TrueBeam STx, including actions the operator should be aware of. 207 devices 12/7/12 – amended to 216 devices. 2014-04-16
2012-01-30 Not classified Device Design An anomaly has been identified with the respiratory gating software of TrueBeam. When importing breath-hold gating protocols, the gating thresholds can be reset to default values, rather than retaining the thresholds established during plan 182 units ***12-12-12 AMENDED TO: 200 units*** 2014-04-16
2012-01-30 Not classified Device Design An anomaly has been identified with the CT Localization module of the FastPlan treatment planning system. If the module reports a significant difference in tilt or spin on a slice and the use elects to “Discard” that slice, an incorrect cal 201 2013-10-21
2012-01-16 Not classified Device Design When using the Standard and Millennium 52-leaf MLC multi-leaf collimators for beam shaping, under specific treatment conditions, dose may be delivered outside of the intended treatment field that exceed the expected transmission dose. 2012-07-26
2012-01-16 Not classified Device Design When using the Standard and Millennium 52-leaf MLC multi-leaf collimators for beam shaping, under specific treatment conditions, dose may be delivered outside of the intended treatment field that exceed the expected transmission dose. 2012-07-26
2011-12-16 Not classified Under Investigation by firm Varian received customer complaints involving ARIA Oncology Information Systems,
where the Planned Total Dose did not calculate correctly in Physicians Intent. It was identified that incorrect values were being stored for Planned No. Fracti
2235 units***12-12-12 AMENDED TO: 2984 units*** 2014-08-06
2011-12-12 Not classified Device Design Varian has discovered that on 4D Integrated Treatment Console and TrueBeam, the ad-hoc CIAO(Complete Irradiated Area Outline) calculation results in the CIAO generation that is different from the CIAO in RT Chart. The 4DITC algorithm adds d 4875 units 2012-07-26
2011-12-12 Not classified Device Design When multiple conical collimator treatment plans are scheduled to be treated in a session, the
Plan Label should be displayed on the BCCV dialog box should match the Plan Label on the
4DITC. However, the name of the plan is not being update
9 2013-12-05
2011-12-12 Not classified Device Design When multiple conical collimator treatment plans are scheduled to be treated in a session, the
Plan Label should be displayed on the BCCV dialog box should match the Plan Label on the
4DITC. However, the name of the plan is not being update
55 2013-12-05
2011-11-28 Not classified Device Design An event has been reported to Varian which entails excessive connector resistance, which caused the actual jaw positions to differ from the intended jaw positions without warning the operator. 6158 units total 2015-06-02
2011-11-28 Not classified Device Design An event has been reported to Varian which entails excessive connector resistance, which caused the actual jaw positions to differ from the intended jaw positions without warning the operator. 6158 units total 2015-06-02
2011-11-23 Not classified Software design An anomaly was discovered when using the 4DITC in combination with an R-Arm to acquire double exposure MV images. 1486 devices 2014-08-06
2011-11-10 Not classified Device Design Failure to retract or park the Varian MLC leaves prior to use of the demountable BrainLAB m3 could result in the Varian MLC leaves interfering with the treatment field defined by the BrainLAB m3 without an interlock being asserted. 205 units***12-12-12 AMENDED TO: 213 units*** 2015-02-19
2011-10-04 Not classified Device Design An anomaly has been identified with the Head Ring posts used by both the Optical Guidance Platform FrameArray module and the Floorstand where the head ring posts may be damaged due to excessive mechanical stress resulting in possible failur 205 kits ( Each kit contains 4 Head Post Rings) 820 HPR’s 2012-07-25
2011-09-09 Not classified Device Design Varian has received reports in which a user has remotely rotated the gantry into contact with the couch or with the patient, in both the manual mode and the automate mode. 5823 devices 2012-07-24
2011-07-21 Not classified Pending The 4D Integrated Treatment Console may erratically fail to load the planned physical wedge accessory without warning or notification when receiving an approved plan from the oncology information system. 1125 2013-08-01
2011-07-20 Not classified Other Potential for Varian Treatment application failing to load the physical wedge filter for a treatment field on a Siemens Mevatron linear accelerator. Delivery of a treatment field without the planned wedge would deliver more dose than intend 118 2013-12-05
2011-06-27 Not classified Software design In certain configurations, the 4DITC can interpret a RapidArc or VMAT treatment field as 3D Conformal Arc Treatment Plan. If a RapidArc or VMAT treatment field is incorrectly interpreted as Conformal Arc, the field will be delivered with a 645 2013-12-05
2011-06-23 Not classified Software design Varian has scheduled for an upgrade of the device from current version to 10.2. There are circumstances in which the 4DITC may be involved in a failure to correctly record treatment history information. 2012-03-15
2011-06-21 Not classified Nonconforming Material/Component Varian has identified a software anomaly in the 3D Match environment, regarding a slight mismatch between CT image and Structures in On-Board Imager w/s. 2268 2012-03-15
2011-06-06 Not classified Device Design When using the HD120 Multi Leaf Collimator for beam shaping, and under specific treatment conditions, dose may be delivered outside of the intended treatment field that exceeds the expected transmission dose. 173***12-20-12 AMENDED TO: 106 units*** 2011-12-23
2011-05-31 Class II Process design Under certain conditions, photon beams in High Energy Clinacs may experience a gradual change in beam symmetry, potentially reaching an asymmetry of up to about 7% before interlock occurs. At maximum asymmetry, this may result in no more th 3943 units 2013-05-15
2011-05-26 Not classified Device Design On Varian Linear Accelerators where the customer may calibrate the collimator angle position readout in reverse, switching the 90 degree and 270 degree positions. 5685 2012-07-13

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer