ProForm™ Thermoplastic
Head only IMRT Clear Vision 2 open face thermoplastic (3.2mm)
Who Else Makes It
Concentrated in Guangdong (2), Jiangsu (2), Beijing (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Guangzhou Tian Hong Medical Technology Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 4 |
| Klarity Medical & Equipment (GZ) Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 3 |
| Elekta Beijing Medical Systems Co., Ltd. | Beijing | Beijing | Contract manufacturer | 1 |
| Manteia Technologies Co., Ltd. | Xiamen | Fujian | Manufacturer | 3 |
| OUR United Corporation | Xian | Shaanxi | Contract manufacturer | 2 |
| Suzhou Linatech Medical Science AND Technology Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 2 |
| Varian Medical Systems China Co., Ltd. | Beijing | Beijing | Manufacturer | 2 |
| Jiangsu Rayer Medical Technology Co., Ltd. | Wuxi | Jiangsu | Manufacturer | 1 |
Record
| Listed by | Medtec LLC, United States |
|---|---|
| FDA product code | IYE |
| Device type | Accelerator, Linear, Medical |
| Device class | Class 2 |
| Regulation | 21 CFR 892.5050 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K180021 |
| Record published | 2021-05-22 |
| Record revised | 2026-05-07 (version 4) |
Specifications
| MRI safety | MR Safe |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number, manufacturing date |
| Storage | Special storage condition: Keep away from sunlight. Single patient multiple use.; Storage environment temperature up to 100 °F |
| Packaging | Pack of 5, pack of 4 |
| Distribution end date | 2020-06-05 |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| PRO3311832SGN | In distribution | |
| PRO339IM1832CLN | In distribution | |
| PRO330IM1832SG | In distribution | |
| PRO331IM1832CL | In distribution | |
| PRO330SPN32 | In distribution | |
| PRO330IM1832CL | In distribution | |
| PRO339IM1832N | In distribution | |
| PRO331IM1832CLN | In distribution | |
| PRO331IM1832S | In distribution | |
| PRO332 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Klarity Medical | Klarity Medical Products, LLC | 891 |
| Orfit Industries | Orfit Industries NV | 680 |
| Aquaplast RT™ | Qfix | 569 |
| Fibreplast® | Qfix | 271 |
| Bionix Radiation Therapy | Bionix Radiation Therapy, LLC | 115 |
| Vac-Lok™ Cushion | Medtec LLC | 100 |
| Visicoil | IZI Medical Products LLC | 86 |
| BodyFIX | 3C-Medical Intelligence GmbH | 84 |
| AlignRT Plus | Vision RT Limited | 72 |
| Fibreplast® Assure™ Open View | Qfix | 72 |
| Accelerator, Linear, Medical | PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH | 71 |
| Thermoplastic Mask | IZI Medical Products LLC | 58 |
Showing 12 of 1,611. All products under Accelerator, Linear, Medical
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K132908 | 2014-03-04 |
| K974703 | 1998-03-10 |
| K974700 | 1998-03-04 |
| K954705 | 1996-01-05 |
| K952729 | 1995-09-15 |
| K952189 | 1995-08-09 |
| K950075 | 1995-07-13 |
| K951947 | 1995-07-12 |
| K951679 | 1995-07-12 |
| K951808 | 1995-07-06 |
| K951717 | 1995-06-28 |
| K950866 | 1995-05-30 |
| K943199 | 1994-12-07 |
| K944315 | 1994-11-22 |
| K935411 | 1994-07-18 |
| K935412 | 1994-07-18 |
| K942282 | 1994-07-18 |
| K935300 | 1994-07-18 |
| K933227 | 1994-07-18 |
| K935021 | 1994-04-07 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2020-05-12 | Class II | Component design/selection | Potential for disengagement of the Varian Style Type-S Extension during patient repositioning. The risk associated with the disengagement of the extension could be a patient fall if the patient is not supported by clinical staff. | 171 units | 2021-03-25 |
| 2019-04-15 | Class II | Device Design | There is a potential for movement of the Solstice Tilting Head Fixation System during patient setup and/or treatment. | 28 units | 2020-10-05 |
| 2009-08-31 | Not classified | Process control | Some of the packages contain the incorrect mask style. | 12 boxes | 2012-03-07 |
| 2008-02-28 | Not classified | Labeling mix-ups | Mislabeled: Fiducial markers were incorrectly labeled. They are marked (0.9x3mm cylindrical) Soft tissue gold markers, but contain (2mm spheres) Bone gold markers. | 33/3-marker pouches | 2008-07-02 |
| 2008-02-28 | Not classified | Labeling mix-ups | Mislabeled: Fiducial markers were incorrectly labeled. They are marked (2mm spheres) Bone gold markers, but contain (0.9x3mm cylindrical) Soft tissue gold markers. | 36/3-marker pouches | 2008-07-02 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.